Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

SENSORS AND TESTS

All main aspects of analytical and bioanalytical sciences is covered by the conference program. AC CA-05 consists of 12 invited lectures and seven symposia General Aspects of Analytical Chemistry, Analytical Methods, Objects of the Analysis,. Sensors and Tests, Separation and Pre-concentration, Pharmaceutical and Biomedical Analysis, History and Methodology of Analytical Chemistry. Conference program includes two special symposia Memorial one, dedicated to Anatoly Babko and Analytical Russian-Germany-Ukrainian symposium (ARGUS-9). [Pg.3]

Another transition metal oxide used as the electrode material in XO, sensors is Cr2O3 [275-281]. Other binary oxides used for XO,. sensors include ZnO [264], V2O5 [282], and SnO2 [278, 279], which has also been used for CO sensors [283]. Indium oxide (In2O3) has been used in a CO sensor and tested in engine exhaust gas [284]. Oxides used as electrodes in sensors for hydrocarbons include Ga2O3 [285],... [Pg.454]

The demonstration provided a practical example on which to base the cost of frozen ground barriers. After subtracting the special expenses for extra sensors and test support, the first year cost per cubic meter for installation and maintenance is estimated as 200, and the average maintenance cost over a 15-year period is estimated as 2.20 per cubic meter per year. The estimate of long term cost is based on calculated thermal losses in a typical soil, equipment amortization expense, power and maintenance costs [Dash 1989]. The cost per unit volume was relatively high because of the small size of the installation. [Pg.249]

Before the performance of the loading we have to apply 5 up to 12 sensors, according their size, on the cylindrical part of the drums and after a short check of the required sensitivity and the wave propagation the pneumatic pressure test monitored by AE can be performed. The selection of the sensors and their positions was performed earlier in pre-tests under the postulate, that the complete cylinder can be tested with the same sensitivity, reliability and that furthermore the localisation accuracy of defects in the on-line- and the post analysis is sufficient for the required purpose. For the flat eovers, which will be tested by specific sensors, the geometrical shape is so complicated, that we perform in this case only a defect determination with a kind of zone-location. [Pg.32]

The eombination in a compact system of an infrared sensor and a laser as excitation source is called a photothermal camera. The surface heating is aehieved by the absorption of the focused beam of a laser. This localisation of the heating permits a three-dimensional heat diffusion in the sample to be examined. The infrared (IR) emission of the surface in the neighbourhood of the heating spot is measured by an infrared detector. A full surface inspection is possible through a video scanning of the excitation and detection spots on the piece to test (figure 1). [Pg.393]

An important part of the decision-making tool flow chart (see Fig. 1) is the redefinition of the specifications by the sensor customer after the surveying and testing of commercial sensor systems. This process almost always involves a downgrading of the expectations of the sensor customer, but it can also force a reaUstic evaluation of what sensor information really needs to be made available and at what cost. [Pg.390]

Frequently recalibrate and test all instruments, read-out devices, sensors and alarms. [Pg.114]

To retard corrosion and to facilitate future maintenance (e.g., allow the non-destructive removal of threaded Junction box covers), all threaded connections should be lubricated with an antiseize compound which will not dry out in the environment. If lubricant is applied to the threaded (or flanged) portion of covers of explosion-proof enclosures, the lubricant must have been tested and approved as suitable for flame path use. It is cautioned that some lubricants contain silicone, which will poison most catalytic gas detector sensors and should not be used near gas detectors. [Pg.546]

Control and supervision systems should be designed with circuit monitoring and self-diagnostic testing to verify that the field sensors and devices are electrically active and connected. The system should alarm when an electrical fault is detected. [Pg.39]

A nano scratch tester (CSEM) was employed to carry out the scratch test. A Rockwell diamond tip with a radius of 2 fim was used to draw at a constant speed 3 mm/min across the coating/substrate system under progressive loading of 130 mN maximum at a fixed rate 130 mN/min. The total length of the scratch scar is 3 mm. The critical load (L ) here is defined as the smallest load at which a recognizable failure occurs. The failure can be observed both by the built-in sensors and by the optical microscope. [Pg.201]

Optical sensors and relay switches are used throughout the test routine for verification. For all possible problems, as well as the sequence in which they occur, the robot must recognize that there is a problem, define the problem, decide how best to resolve the problem, perform the necessary operations to overcome the problem, and enable the system to resume testing. This is an AI application area and a critical feature, mainly because the system operates unattended and measurements are taken overnight and during weekends. [Pg.34]

O2, and hydrocarbons, leading to a NH3 selective sensor. Arguments in favor of using a zeolite-based sensor in NH3 detection for automotive apphcations are low cost, high temperature stability, and suitability for use in thick-film technology, of common use in the automotive industry [72]. The sensors were tested on an engine test bank and the authors claim that the sensor itself meets aU the technological and economical demands of the automotive industry [73]. [Pg.227]

A simplification of the polarization resistance technique is the linear polarization technique in which it is assumed that the relationship between E and i is linear in a narrow range around E . Usually only two points ( , 0 are measured and B is assumed to have a constant value of about 20 mV. This approach is used in field tests and forms the basis of commercial corrosion rate monitors. Rp can also be determined as the dc limit of the electrochemical impedance. Mansfeld et al. used the linear polarization technique to determine Rp for mild steel sensors embedded in concrete exposed to a sewer environment for about 9 months. One sensor was periodically flushed with sewage in an attempt to remove the sulfuric acid produced by sulfur-oxidizing bacteria within a biofilm another sensor was used as a control. A data logging system collected Rp at 10-min intervals simultaneously for the two corrosion sensors and two pH electrodes placed at the concrete surface. Figure 2 shows the cumulative corrosion loss (Z INT) obtained by integration of the MRp time curves as ... [Pg.211]

With the complex where L = pyridine an optical nanosensor was developed [135-137], the method used to fix the vapochromic material to the optical fiber was the electrostatic self assembling method (ESA) and the light source used was an 850 nm LED. The sensor was tested for two different alcohols (ethanol and methanol) and it was possible to distinguish between different concentrations. It was also possible to discriminate between the two different alcohols. [Pg.122]

Deposition of sensor layers is possible on fibre Flow-through cell allowing the optics, planar waveguides, and test strips simultaneous exposure of the membrane to... [Pg.318]

The first intravascular sensor for simultaneous and continuous monitoring of the pH, pC>2, and pCC>2 was developed by CDI-3M Health Care (Tustin CA)14 based on a system designed and tested by Gehrich et al.15. Three optical fibres (core diameter = 125 pm) are encapsulated in a polymer enclosure, along with a thermocouple embedded for temperature monitoring (Figure 3). pH measurement is carried out by means of a fluorophore, hydroxypyrene trisulfonic acid (HTPS), covalently bonded to a matrix of cellulose, attached to the fibre tip. Both the acidic ( eXc=410 nm) and alkaline ( exc=460 nm) excitation bands of the fluorophore are used, since their emission bands are centred on the same wavelength (/-cm 520 nm). The ratio of the fluorescence intensity for the two excitations is measured, to render the sensor relatively insensitive to fluctuations of optical intensity. [Pg.420]

Other optodes have been developed and tested in-vivo, all of them using a fluorophore, the fluorescence of which is quenched by oxygen. In the intravascular sensor developed by CDI, previously described, a specially synthesised fluorophore, a modified decacyclene ( Lexc=385 nm, em=515 nm), is combined with a second reference-fluorophore that is insensitive to oxygen, and is incorporated into a hydrophobic silicon membrane that is permeable to oxygen. [Pg.427]

Figure 9. Clinical test on a patient response curve of the optical fibre sensor and of Tonocap. Figure 9. Clinical test on a patient response curve of the optical fibre sensor and of Tonocap.

See other pages where SENSORS AND TESTS is mentioned: [Pg.299]    [Pg.294]    [Pg.301]    [Pg.313]    [Pg.924]    [Pg.354]    [Pg.174]    [Pg.417]    [Pg.299]    [Pg.294]    [Pg.301]    [Pg.313]    [Pg.924]    [Pg.354]    [Pg.174]    [Pg.417]    [Pg.365]    [Pg.1061]    [Pg.180]    [Pg.99]    [Pg.465]    [Pg.156]    [Pg.239]    [Pg.73]    [Pg.31]    [Pg.113]    [Pg.335]    [Pg.496]    [Pg.82]    [Pg.22]    [Pg.39]    [Pg.41]    [Pg.42]    [Pg.46]    [Pg.68]    [Pg.262]    [Pg.293]    [Pg.423]    [Pg.306]    [Pg.312]   


SEARCH



Organization and Planning of Testing Zirconia Sensors

Test Strip and Optoelectronic Sensors

© 2024 chempedia.info