Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Safety pressure

An introduction to health and safety Pressure systems - Safety and you... [Pg.578]

Receivers are pressure vessels covered by the provisions of BS.4434 1980 and require safety pressure relief devices as outlined in Section 6.10. In cases where there is no shut-off valve between the condenser and receiver, such protection may be fitted to one or the other, providing the total volume is considered. [Pg.80]

Pipework and other components should be insulated after the safety pressure test, but usually before prolonged running of the plant, since it is very difficult to remove water and frost once it has formed. Only the low-pressure piping is insulated, where it does not form part of the evaporator, i.e. after the expansion valve, where this may be outside the cooled space, and from the evaporator back to the compressor. Basic materials are cork and the expanded plastics. These are sufficiently rigid to be moulded to the correct shape, remain firmly in place, and support the external vapour barrier which is essential to prevent the ingress of water vapour (see also Chapter 15). [Pg.140]

Insolubility of (Cryo)grinding Concentration Labour intensive (Cryo)grinding Safety Pressure device... [Pg.64]

EN 4126 Part 5 = Controlled Safety Pressure Relief Systems (CSPRS)... [Pg.17]

Power actuated/assisted safety valves (CSPRS - controlled safety pressure relief system) A spring-operated safety valve actuated or assisted by an externally powered control device which can be hydraulic, pneumatic or electric (Figure 3.15). [Pg.52]

The controlled safety pressure relief system (CSPRS) (Figure 5.31) is a special type of actuated SRV that has mainly been used in Europe and in power applications, primarily in the German power industry, for the last 40 years. So far, it has not been used extensively in other parts of the world, but it has become more important since it has its own EN/ISO 4126 Part 5 code in the new European regulation. [Pg.120]

CEN - European Committee for Standardization Brussels wvwv.cenorm.be EN/ISO 4126- Safety Devices for Protection Against Excessive Pressure Part 1 - Safety Valves Part 2 - Bursting Disc Safety Devices Part 3 - Safety Valves and Bursting Disc Safety Devices in Combination Part 4 - Pilot Operated Safety Valves Part 5 - Controlled Safety Pressure Relief Systems Part 6 - Application, Selection and Installation of Bursting Disc Safety Devices Part 7 - Common Data... [Pg.306]

TGL 30042 has defined a four-zone concept for areas hazardous due to combustible gases, vapours and mists EG 1, comparable with zone 0 EG 2 and EG 3, covering zone 1 EG 4, comparable with zone 2. In contradiction to the majority of standards covering the zone 1 requirements with all types of protection such as flameproof enclosure, increased safety, pressurization, oil immersion, intrinsic safety, powder filling, EG 2 excludes the general application of, e.g., increased safety e, which has been the domain of EG 3. [Pg.54]

Warning Never connect a gas cylinder directly to a closed system that is not specially designed to withstand high pressures (such as a combustion bomb for heats of combustion). Even when a regulator is used, remember that the diaphragm valve may slowly leak arrange for some kind of safety pressure release, if only a rubber tubing connection that can be easily blown off. [Pg.646]

Between the feeding system and the reactor there is a view port that is used to ignite the bed and acts as well as a safety pressure release valve. [Pg.432]

Two glass reactors for 50-150 psi gas/solution reactions are described. The first is a simple reactor with safety pressure release, sample withdrawal port, and quick connect hookup. The second incorporates a metal pressure-equalizing addition funnel for reactant additions to the pressurized reaction mixture. Plans and commercially—available parts lists for both designs are provided. [Pg.198]

Safety feeds benefits Coalmine production is a high risk industry, which bears especially high safety pressure. Once accidents happen, both units and individuals would suffer direct or indirect economic losses. [Pg.756]

Provide interlocking of feed system with exit gas analysis, flame control, and ( crating pressure in system shall be always negative to prevent escape of gases), tripping of scrubber circulation pump must stop ID fan and fresh feeding of waste. Safety pressure release valve shall open if there is positive pressure in the system. [Pg.139]

An offshore oil producer requires all subcontractors to undergo safety training and to conform to stringent safety standards. I was told that it had terminated the contract of one of its supply vessels because of an unacceptably high number of injuries and incidents. This is perhaps the most dramatic evidence of private sector safety pressures uncovered in this study. [Pg.71]

Big Buildings is a national firm with numerous construction jobs in hand at any one time. Thus, although it employs only perhaps ten workers directly on any one site, this adds up to many hundreds around the country. One might wonder, therefore, whether compensation costs could after all exert some safety pressure on it. [Pg.131]

C-14 Procedures for Testing of DOT Cylinder Pressure Relief Device Systems. Describes a new set of test procedures and apparatus for fire testing compressed gas cylinder safety (pressure) relief devices as required by DOT regulation, 49 CFR, Section 173.34(d). The procedures are applicable for cylinders which are less than 500 lbs. internal water volume and are designed to provide a means of testing to DOT requirements anywhere, with reliable test data and repeatable test results. Previous edition cited in 49 CFR (13 pages). [Pg.669]

There are four basic types of safety pressure relief devices in use. [Pg.488]


See other pages where Safety pressure is mentioned: [Pg.471]    [Pg.28]    [Pg.111]    [Pg.27]    [Pg.210]    [Pg.36]    [Pg.120]    [Pg.120]    [Pg.305]    [Pg.338]    [Pg.361]    [Pg.2425]    [Pg.144]    [Pg.109]    [Pg.234]    [Pg.455]    [Pg.219]    [Pg.28]    [Pg.43]    [Pg.71]    [Pg.255]    [Pg.45]    [Pg.255]    [Pg.39]    [Pg.75]    [Pg.1627]    [Pg.75]   
See also in sourсe #XX -- [ Pg.200 , Pg.217 ]




SEARCH



Back pressure on safety valve

Blood pressure drug safety

Controlled safety pressure relief

Controlled safety pressure relief systems

Extruder pressure-head safety

High Line Pressure Safety Instrumented Function (SIF)

High-pressure safety valves sizing

Low-pressure safety injection system

PLANT SAFETY AND PRESSURE RELIEVING OPERATIONS

Pressure Safety Devices

Pressure System Safety Regulations

Pressure relief and safety devices

Pressure safety measures

Pressure safety relief valves

Pressure safety valves

Pressurizer safety valves

Rules, safety, 1-10 pressure units

Safety Analysis Code for Subcritical Pressure Condition

Safety Analysis Code for Supercritical Pressure Condition

Safety design pressure

Safety high pressure

Safety maximum surface pressure

Safety pressure relief

Safety pressure relief devices

Sizing of High-Pressure Safety Valves for Gas Service

© 2024 chempedia.info