Filling powder

on this basis, low power electrical components such as semiconductors, capacitors, transformers, relays (which shall be sealed in order to prevent ingress of granules into the contact space and mechanical blocking caused hereby), resistors and fuses can be explosion protected by embedding in a [Pg.130]

The q-standards restrict the application of this type of explosion protection to electrical apparatus or components with  [Pg.131]

The total stored energy of all capacitors in an enclosure of a powder-filled electrical apparatus or component shall not exceed 20 J in normal operation. [Pg.131]

The size of granules shall lie within the following sieve limits (according to ISO 565)  [Pg.131]

The enclosure of q-apparatus in its normal service condition shall comply at least with IP 54, according to IEC 60529. For higher degrees of protection the enclosure shall be fitted with a breathing device, this complying with [Pg.131]

Perform general operational controls verification testing. [Pg.120]

Operate system throughout the range of operating design specifications or range of intended use. [Pg.120]

Verify that all safety devices of the powder filling machine are operating as specified in the manual. [Pg.120]

Verify that recommended lubricants are used during machine operation. [Pg.120]

Verify that all lubricants such as oil and grease are kept in clean, sealed containers so that no dust or moisture penetrates. [Pg.120]


Electrical apparatus for potentially explosive atmospheres - Powder filling q . Superseded BS EN 50017 1994 which remains cuiTcnt... [Pg.591]

Thermal insulation is available over a wide range of temperatures, from near absolute zero (-273 C) ( 59.4°F) to perhaps 3,(1()0°C (5,432°F). Applications include residential and commercial buildings, high- or low-temperature industrial processes, ground and air vehicles, and shipping containers. The materials and systems in use can be broadly characterized as air-filled fibrous or porous, cellular solids, closed-cell polymer foams containing a gas other than air, evacuated powder-filled panels, or reflective foil systems. [Pg.674]

Capsule-filling equipment has been the subject of several reviews [18, 40-45], Four main dosing methods may be identified for powder filling ... [Pg.347]

G. Design of Hard Gelatin Capsule Formulations for Powder Fill... [Pg.362]

Dry powders for reconstitution as an injectable product may be produced by several methods filling the product into vials as a liquid and freeze-drying, aseptic crystallization followed by powder filling, and spray-drying followed by powder filling. A brief discussion of each follows. [Pg.398]

Aseptic Crystallization and Dry Powder Filling. Aseptic crystallization is primarily used for manufacture of sterile aqueous suspensions. However, if the physical form of the drug is critical to quality of the final product, better control over physical form can be attained by aseptic crystallization because a large variety of organic solvents can be used to control the crystallization process. In aseptic crystallization, the drug is... [Pg.404]

For the production of preceramic slurries, fillers in the submicron range have to be used to achieve homogeneous infiltration of a fiber bundle with several thousands of filaments. This requires detailed knowledge of the rheological behavior of the powder-filled dissolved polymers. Additives are necessary to achieve high filler contents and good rheological behavior. [Pg.305]

Weigh out 2100 mg of sulfasalazine powder, 28 mg of prednisone (use aliquot method for weighing this quantity), and add sufficient lactose to obtain a total of 2730 mg of the powder. Fill 195 mg in each of the 14 capsules that are required to be dispensed. [Pg.374]

Ribbon blender Powders filled to >70 % of vessel volume [331... [Pg.262]

Suspecting that constant-flow conditions are not realized even for capillaries and that the effect is due most probably to the chamber volume instead of kinetic effects as explained by the earlier investigators, data were collected using empty capillaries and capillaries filled with glass powder. The results show that for glass-powder-filled capillaries, the minimum is absent (K8). [Pg.276]

Catalyst powder fills the boring as the die moves under the feeder mechanism while the lower piston moves down. The feeder mechanism scrapes the upper end of the boring clean. At this moment, the position of the lower piston defines the amount of catalyst powder in the finished pellet. [Pg.74]

Irradiated sucrose or sodium carbonate (for powder fill run)... [Pg.905]

Practical Considerations in the Scale-Up of Powder-Filled Hard Shell Capsule Formulations... [Pg.409]

The casting powder fills ca. j of the mould. Then the inside of the mould is evacuated to remove air and residual solvent vapours. [Pg.676]

Venting. Air that is in an otherwise empty bin, for example, must be displaced from the bin as powder fills it. If this air is forced through material in the V-blender, perhaps sealed tight in the interest of containment, this can induce fluidization segregation within the blender. To avoid this, a separate pathway or vent line to allow the air to escape without moving through the bed of material can reduce segregation. [Pg.148]

HAMMER LUMPS OF BITUMINOUS COAL INTO A COARSE POWDER. FILL FUNNEL WITH IT. BRING FUNNEL INTO LARGE JAR. [Pg.83]

The pharmaceutical industry produces tablets almost exclusively on rotary tablet presses from pilot plant to commercial manufacture. The output from different tablet presses may range from a few thousand tablets per hour to more than 1 million tablets per hour. By design, the compression event occurs using three parts a die, lower punch, and upper punch. The dies and punches are mounted on a rotating turret. The shape of the die controls the shape of the tablets, while the distance between the lower and upper punch tips at the maximum compression force determines the thickness of the tablets. The tablet compression process is divided into three steps powder filling into the die, compression, and tablet ejection from the die.85... [Pg.195]

First, the die is filled when it passes beneath a stationary feed frame and the lower punch is in the filling position. Tablet weight variation is dependent on uniform powder filling into the die cavity. Since the residence time of the die under the feed frame is very short, the formulation blend must flow easily and reproducibly. [Pg.195]

Most unmodified polymeric resins have a very low thermal conductivity. There are certain applications where high levels of thermal conductivity are required. For example, power electronic devices and other heat-generating components are bonded to heat sinks and other metal sources. Metal powder filled adhesives, such as those described above for electrically conductive adhesives, can conduct both heat and electricity. [Pg.172]


See other pages where Filling powder is mentioned: [Pg.546]    [Pg.1891]    [Pg.165]    [Pg.347]    [Pg.374]    [Pg.404]    [Pg.404]    [Pg.405]    [Pg.307]    [Pg.182]    [Pg.262]    [Pg.99]    [Pg.245]    [Pg.246]    [Pg.242]    [Pg.205]    [Pg.23]    [Pg.23]    [Pg.18]    [Pg.880]    [Pg.196]    [Pg.434]    [Pg.436]    [Pg.405]    [Pg.186]    [Pg.646]    [Pg.32]    [Pg.68]    [Pg.186]   
See also in sourсe #XX -- [ Pg.104 , Pg.105 ]

See also in sourсe #XX -- [ Pg.446 ]




SEARCH



Equipment powder filling machine

Explosion protection powder filling

Polymers powder-filled

Powder filling capsules

Powder filling dosing tube

Powder filling optimization formulation

Powder filling properties

Powder-filled composites

Practical Considerations in the Scale-Up of Powder-Filled Hard Shell Capsule Formulations

Semisolid powder filling

Thermal expansion powder-filled composite

© 2024 chempedia.info