Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Safeguards installing

Procedures for regular maintenance of safeguards installed on heat-producing equipment to prevent accidental ignition of combustible materials ... [Pg.309]

Instruction on the problem of safeguarding installations under repair against unauthorized or inadvertent switching-on. [Pg.355]

What records Fire prevention plan must include o list of workplace fire hazards o procedures to handle and store hazardous materials o potential ignition sources and appropriate fire protection o procedures to control accumulations of fiammable and combustible wastes o procedures for maintenance of safeguards installed on heat-producing equipment o names and job titles of individuals who control fuel source hazards Written plan is required for employers with 11 or more employees Verbal plan is allowed for employers with 10 or fewer employees... [Pg.252]

These recommendations are for low-pressure applications with water and other fluids that do not significantly affect the properties of the particular thermoplastic. The upper temperature limits are reduced at higher pressures, depending on the comhination of fluid and expected service life. Lower temperature limits are affected more hy installation, environment, and safeguarding than hy strength. [Pg.948]

A toller with a good histoiy of HS E performance is able to obtain advantageous insurance rates and expends less of their revenue on legal problems, thus helping with their potential for cost competitiveness in the final bid. A toller in good financial standing is more likely to expend capital to install adequate safeguards. [Pg.25]

Ambient temperature, altitude and atmospheric conditions at the place of installation of electrical equipment are considered to be the service conditions for the equipment to operate and perform its duties. All electrical equipment is designed for specific service conditions and variations may influence its performance. Below we analyse the influence of such non-standard service conditions on the performance of equipment and the required safeguards to achieve its required performance. [Pg.362]

To quote from the official report, The decision to override the individual controls on the loading arms by means of a central switchboard, without the most rigid safeguards, was a tragic one. After its installation an accident from that moment on became inevitable sooner or later. [Pg.263]

Reasonable Precautions Condition under which the client is required to take reasonable precautions to safeguard the insured property and secure the premises, including the installation, use and maintenance of any security precautions stipulated or agreed with the insurance company. [Pg.166]

In addition to the use of such manual valves, automatically operated valves may be considered as an additional safeguard in certain installations. These can be connected to (among other interlocks) panic buttons sited within the building, which they are protecting. This is a recommended requirement for buildings containing plant of over 2 MW total heat input and supplied with gas at above 1 bar. [Pg.288]

The most common device installed in hydraulic systems to prevent foreign particles and contaminations from remaining in the system are referred to as hlters. They may be located in the reservoir, in the return line, in the pressure line, or in any other location in the system where the designer of the system decides they are needed to safeguard the system against impurities. [Pg.607]

The question of safeguarding against wrong materials being installed in a plant has been a focus of much attention recentlyMistakes can arise in two ways ... [Pg.27]

Since the aggregate risks from Process Unit 2 are largely the result of single event—brittle fracture—the qualitative hazard assessment identified potential safeguards that could be put in place to prevent a brittle fracture occurrence. It was decided that the best option would be to install an emergency shutdown system in Process Unit 2 to prevent pressuring the nitrogen vapor vessel if a cold temperature situation was present. [Pg.128]

Consequences of contaminating hot and high boiling liquids with low boilers can be estimated using thermodynamics. If these scenarios are possible, relief valves should also be installed to mitigate these events, or adequate safeguards should be added to the system to prevent the specific hazard scenario. [Pg.553]

In evaluating a piping installation design to determine what safeguarding may exist or is necessary, the following should be reviewed ... [Pg.176]

Excessive amounts of fluoride in the soil can cause tooth and bone damage in livestock. Paris of Arkansas. California. South Carolina, and Texas have soils abnormally high in fluorine content. In serious situations, diarrhea and emaciation will he exhibited by the livestock. The effects depend upon the fluorine source and species of livestock. Exceptionally high fluoride levels can he encountered near smelters where pollution safeguards have not been installed or are ineffectively maintained. As cninpared with other livestock, pigs can tolerate much more fluorine (up lo nearly 300 ppm of fluorine derived front rock phosphates). [Pg.659]

Other of such standards which are useful are the EN 764-7 and EN 12952-10 Water-tube boilers and auxiliary installations - Requirements for safeguards against excessive pressure. Although its Annex ZA shows that it supports the PED clauses 2.11 and 7.3, this standard does not give any indication on the set pressure and the overpressure of the Safety Relief Valves, in which case one can refer back to the above. [Pg.61]

Adequate safeguards are installed to prevent mishaps from occurring. The details will be found in the literature supplied by the manufacturer. [Pg.337]

Process safeguards for the carbon beds were discussed and previously defined. A flame arrestor was purchased and delivered to the terminal site. It was to be placed on the vapor line from the tanks. Unfortunately, the flame arrestor was not installed. [Pg.52]


See other pages where Safeguards installing is mentioned: [Pg.147]    [Pg.147]    [Pg.406]    [Pg.411]    [Pg.24]    [Pg.1688]    [Pg.426]    [Pg.433]    [Pg.380]    [Pg.465]    [Pg.140]    [Pg.124]    [Pg.95]    [Pg.95]    [Pg.541]    [Pg.200]    [Pg.208]    [Pg.160]    [Pg.21]    [Pg.264]    [Pg.208]    [Pg.807]    [Pg.219]    [Pg.338]    [Pg.194]    [Pg.211]    [Pg.530]    [Pg.182]   