Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Piping design and installation

PVC Pipe, Design and Installation, AWWA Manual No. M23, American Water Works Association, Denver, 1980. [Pg.774]

M22, Sizing Water Service Lines and Meters, First Edition, 1975, 30022PA M23, PVC Pipe-Design and Installation, First Edition, 1980, 30023PA M24, Dual Water Systems, Second Edition, 1994, 30024PA... [Pg.150]

M19, Emergency Planning for Water Utilities, 30019 M20, Water Chlorination Chloramination Practices and Principles, 30020 M21, Groundwater, 30021 M22, Sizing Water Service Lines and Meters, 30022 M23, PVC Pipe—Design and Installation, 30023 M24, Planning for the Distribution of Reclaimed Water, 30024... [Pg.113]

M54, Developing Rates for Small Systems, 30054 M55, PE Pipe—Design and Installation, 30055 M56, Nitrification Prevention and Control in Drinking Water, 30056 M57, Algae Source to Treatment, 30057 M58, Internal Corrosion Control in Water Distribution Systems, 30058... [Pg.113]

The selection and appHcation of an expansion joint is not as simple as selecting a pipe fitting or a valve and requires a sound understanding of the joint s capabihties and limitations. Improper appHcation of any type of joint can result in serious or damaging effects. However, when properly selected and integrated into the piping system, satisfactory service and safe operation can be expected. Selection and appHcation of beUows expansion joints require special attention to design and installation. [Pg.65]

This section describes the requirements for the design and installation of pressure relief valve inlet and outlet piping manifolds and valving, including safety valve and flare headers. [Pg.199]

No professional mechanical engineer was on the site at the time. The workers designed and installed the pipe by judgment from experience and got the plant on line in a few days. Flowcver, they did not allow sufficiently for the stress on a 20 inch pipe at 150 psi pressure, or the weakening of the metal from operation at 150° C (302 "F). It was designed on a chalkboard in the workshop and installed with jerry-rigged scaffolding... [Pg.250]

API Recommended Practice 14E, Fifth Edition Recommended Practice for Design and Installation of Offshore Production Platform Piping Systems, October 1991. [Pg.1382]

Code of Practice No. 22, LPG piping system design and installation... [Pg.308]

American Petroleum Institute. 2007. API RP14E. Recommended practice for design and installation of offshore production platform piping systems. Washington, DC American Petroleum Institute. [Pg.210]

Where pipe-lines are used for delivery of ingredients or supply of bulk product, care should be taken to ensure that such systems are easy to clean. Pipe-work should be designed and installed so tat it may be readily dismantled and cleaned. [Pg.493]

Ductwork, light fixtures, heating units and other components shall be designed and installed so as to prevent areas which are inacessible to cleaning. The drain pipes snail be provided with a siphon and. if necessary, a back-up control. [Pg.659]

McClelland, B., Focht Jr., J. A., and Emrich, W. J. (1967), Problems in design and installation of heavily loaded pipe piles. Proceedings, Conference Civil Engineering in the Oceans, ASCE, pp. 601-634. [Pg.538]

Flexible connectors need constant observation to check for separations. They are designed to prevent transmission of vibration, but they themselves are not immune to vibration problems. Watch for tears, wear spots, and separations. Replace with less severe bends, or reposition equipment to minimize misalignment. Make sure that all pipe fitters and installers know that flexible connectors are not to be used instead of pipe fittings. Their only purposes are to absorb vibrations and to correct for minor misalignment. [Pg.380]

Stress analysis shall be carried out for pipelines carrying high-temperature fluids. Ensure that the pipe supports and bellows are properly designed and installed in the pipelines at appropriate places to take care of thermal shocks, and gasket material... [Pg.79]

This logical completion of the safety analyses highlighted some negative consequences of having adopted the extreme assumption of the complete rupture of the largest pipe. In particular, for the protection of components from the pipe whip, many cumbersome plastic deformation restraints had to be designed and installed on the pipe runs, in order to prevent the excessive displacement of the pipes themselves. The space occupied by these restraints resulted in a further reduction of the already small space around components and made it more difficult... [Pg.130]

The anchorage of components, especially with cantilevered parts (actuators of valves, and so on), sufficient slack and flexibility in the mechanical and electrical connections (pipes and cables), sufficient gaps between components and between components and structures, are the principal design and installation characteristics to be examined. A specific consideration is deserved by electro-mechanical... [Pg.170]

The pumps, located in the buildings, are connected to each SG via independent piping system (two systems are available working in parallel). These piping systems are designed and installed in a manner to provide full reliability of feed water supply to the SGs. They are completely separated from the units feed water systems, originally designed. [Pg.27]


See other pages where Piping design and installation is mentioned: [Pg.124]    [Pg.4]    [Pg.124]    [Pg.4]    [Pg.1126]    [Pg.399]    [Pg.399]    [Pg.814]    [Pg.116]    [Pg.689]    [Pg.142]    [Pg.152]    [Pg.158]    [Pg.211]    [Pg.354]    [Pg.450]    [Pg.499]    [Pg.949]    [Pg.354]    [Pg.4047]    [Pg.1294]    [Pg.96]    [Pg.188]    [Pg.1295]    [Pg.264]    [Pg.397]    [Pg.1130]    [Pg.98]   
See also in sourсe #XX -- [ Pg.4047 ]




SEARCH



Installation Piping

Installations design

Pipe design

Piping design

© 2024 chempedia.info