Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Refractive index analysis

OS 61] ]R 20] ]P 44] The polymer molecular-weight distribution of a static mixer-based processing, which was determined both by UV and refractive index analysis. [Pg.504]

The refractive index analysis considered in the previous subsection was based on monitoring of a single resonance in the transmission spectrum. The information... [Pg.364]

It should be mentioned that it is possible to determine solid-solid phase transitions by the Morey technique. In this case solids are heated for extended periods above and below a transition temperature and identification of a ciystal form may be made either by X-ray analysis or by microscopic examination, as with a Becke line refractive index analysis. Once the refractive indexes of the two crystal forms are established, walking in on a transition can be done in much the same way a melting point can be established. [Pg.120]

Figure 1. shows the measured phase differenee derived using equation (6). A close match between the three sets of data points can be seen. Small jumps in the phase delay at 5tt, 3tt and most noticeably at tt are the result of the mathematical analysis used. As the cell is rotated such that tlie optical axis of the crystal structure runs parallel to the angle of polarisation, the cell acts as a phase-only modulator, and the voltage induced refractive index change no longer provides rotation of polarisation. This is desirable as ultimately the device is to be introduced to an interferometer, and any differing polarisations induced in the beams of such a device results in lower intensity modulation. [Pg.682]

The real utility of d comes in the analysis of thin films. Consider a substrate of refractive index supporting a thin film of thickness d and refractive index in contact with an internal reflection element (the prism) of refractive index as shown in Figure 24. In this case, d depends on the polarization of the incident light beam and is given by... [Pg.287]

Microscopy (qv) plays a key role in examining trace evidence owing to the small size of the evidence and a desire to use nondestmctive testing (qv) techniques whenever possible. Polarizing light microscopy (43,44) is a method of choice for crystalline materials. Microscopy and microchemical analysis techniques (45,46) work well on small samples, are relatively nondestmctive, and are fast. Evidence such as sod, minerals, synthetic fibers, explosive debris, foodstuff, cosmetics (qv), and the like, lend themselves to this technique as do comparison microscopy, refractive index, and density comparisons with known specimens. Other microscopic procedures involving infrared, visible, and ultraviolet spectroscopy (qv) also are used to examine many types of trace evidence. [Pg.487]

Table 4 lists the specifications set by Du Pont, the largest U.S. producer of DMF (4). Water in DMF is deterrnined either by Kad Fischer titration or by gas chromatography. The chromatographic method is more rehable at lower levels of water (<500 ppm) (4). DMF purity is deterrnined by gc. For specialized laboratory appHcations, conductivity measurements have been used as an indication of purity (27). DMF in water can be measured by refractive index, hydrolysis to DMA followed by titration of the Hberated amine, or, most conveniendy, by infrared analysis. A band at 1087 cm is used for the ir analysis. [Pg.514]

Hplc techniques are used to routinely separate and quantify less volatile compounds. The hplc columns used to affect this separation are selected based on the constituents of interest. They are typically reverse phase or anion exchange in nature. The constituents routinely assayed in this type of analysis are those high in molecular weight or low in volatility. Specific compounds of interest include wood sugars, vanillin, and tannin complexes. The most common types of hplc detectors employed in the analysis of distilled spirits are the refractive index detector and the ultraviolet detector. Additionally, the recent introduction of the photodiode array detector is making a significant impact in the analysis of distilled spirits. [Pg.89]

When simple Hquids like naphtha are cracked, it may be possible to determine the feed components by gas chromatography combined with mass spectrometry (gc/ms) (30). However, when gas oil is cracked, complete analysis of the feed may not be possible. Therefore, some simple definitions are used to characterize the feed. When available, paraffins, olefins, naphthenes, and aromatics (PONA) content serves as a key property. When PONA is not available, the Bureau of Mines Correlation Index (BMCI) is used. Other properties like specific gravity, ASTM distillation, viscosity, refractive index. Conradson Carbon, and Bromine Number are also used to characterize the feed. In recent years even nuclear magnetic resonance spectroscopy has been... [Pg.434]

Composition The law of mass aclion is expressed as a rate in terms of chemical compositions of the participants, so ultimately the variation of composition with time must be found. The composition is determined in terms of a property that is measured by some instrument and cahbrated in terms of composition. Among the measures that have been used are titration, pressure, refractive index, density, chromatography, spectrometry, polarimetry, conduclimetry, absorbance, and magnetic resonance. In some cases the composition may vary linearly with the observed property, but in every case a calibration is needed. Before kinetic analysis is undertaken, the data are converted to composition as a function of time (C, t), or to composition and temperature as functions of time (C, T, t). In a steady CSTR the rate is observed as a function of residence time. [Pg.707]

Thin-layer chromatography (TLC) is used both for characterization of alcohol sulfates and alcohol ether sulfates and for their analysis in mixtures. This technique, combined with the use of scanning densitometers, is a quantitative analytical method. TLC is preferred to HPLC in this case as anionic surfactants do not contain strong chromophores and the refractive index detector is of low sensitivity and not suitable for gradient elution. A recent development in HPLC detector technology, the evaporative light-scattering detector, will probably overcome these sensitivity problems. [Pg.283]

Sodium dodecyl sulfate present in hydrophilic ointments has been determined by TLC on silica gel with flame ionization detection, which was considered better than the colorimetric method. TLC is preferred to HPLC in this case due to the low sensitivity of the refractive index detector that makes difficult the analysis of small amounts of sodium dodecyl sulfate [284]. [Pg.283]

The refractive index detector, in general, is a choice of last resort and is used for those applications where, for one reason or another, all other detectors are inappropriate or impractical. However, the detector has one particular area of application for which it is unique and that is in the separation and analysis of polymers. In general, for those polymers that contain more than six monomer units, the refractive index is directly proportional to the concentration of the polymer and is practically independent of the molecular weight. Thus, a quantitative analysis of a polymer mixture can be obtained by the simple normalization of the peak areas in the chromatogram, there being no need for the use of individual response factors. Some typical specifications for the refractive index detector are as follows ... [Pg.185]

The separation was carried out on a TSKgel Amide-80 column 4.6 mm i.d. and 25 cm long with a mobile phase consisting of a 80% acetonitrile 20% water mixture. The flow rate was 1 ml/min and the column was operated at an elevated temperature of 80°C. The saccharides shown were 1/ rhamnose, 2/ fucose, 3/ xylose, 4/ fructose, 5/ mannose, 6/ glucose, 7/ sucrose and 8/ maltose. The analysis was completed in less than 20 minutes. These types of separations including other biomonomers, dimers and polymers are frequently carried out employing refractive index detection. [Pg.186]

The normalization method is the easiest and most straightforward to use but, unfortunately, it is also the least likely to be appropriate for most LC analyses. To be applicable, the detector must have the same response to all the components of the sample. An exceptional example, where the normalization procedure is frequently used, is in the analysis of polymers by exclusion chromatography using the refractive index detector. The refractive index of a specific polymer is a constant for all polymers of that type having more than 6 monomer units. Under these conditions normalization is the obvious quantitative method to use. [Pg.271]

Solvent — The transition energy responsible for the main absorption band is dependent on the refractive index of the solvent, the transition energy being lower as the refractive index of the solvent increases. In other words, the values are similar in petroleum ether, hexane, and diethyl ether and much higher in benzene, toluene, and chlorinated solvents. Therefore, for comparison of the UV-Vis spectrum features, the same solvent should be used to obtain all carotenoid data. In addition, because of this solvent effect, special care should be taken when information about a chromophore is taken from a UV-Vis spectrum measured online by a PDA detector during HPLC analysis. [Pg.467]

Both recycled and non-recycled essential oils met the standards for specific gravity, angular rotation and refractive index of the Food Chemicals Codex [22] and United States Pharmacopeia [23] for cold-pressed lemon peel oil. Results of gas chromatography analysis show the same compounds and levels in both systems, specially for the oxygenated compounds as citral (neral and geranial). Therefore, recycling the aqueous discharges to the extractor does not cause undesirable modifications. [Pg.969]


See other pages where Refractive index analysis is mentioned: [Pg.504]    [Pg.504]    [Pg.1734]    [Pg.2866]    [Pg.1032]    [Pg.1081]    [Pg.1287]    [Pg.393]    [Pg.365]    [Pg.134]    [Pg.283]    [Pg.70]    [Pg.155]    [Pg.66]    [Pg.60]    [Pg.317]    [Pg.1324]    [Pg.140]    [Pg.267]    [Pg.560]    [Pg.54]    [Pg.426]    [Pg.260]    [Pg.368]    [Pg.370]    [Pg.375]    [Pg.445]    [Pg.189]    [Pg.413]    [Pg.243]    [Pg.309]    [Pg.10]    [Pg.498]    [Pg.332]    [Pg.120]   
See also in sourсe #XX -- [ Pg.22 ]




SEARCH



APPLYING THE SCIENCE 5.1 Glass Analysis and Refractive index

Flow-injection analysis refractive index effect

Refractive index detection food analysis

Refractive index detection polymer analysis

© 2024 chempedia.info