Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Proper functions parameter

Empirical energy functions can fulfill the demands required by computational studies of biochemical and biophysical systems. The mathematical equations in empirical energy functions include relatively simple terms to describe the physical interactions that dictate the structure and dynamic properties of biological molecules. In addition, empirical force fields use atomistic models, in which atoms are the smallest particles in the system rather than the electrons and nuclei used in quantum mechanics. These two simplifications allow for the computational speed required to perform the required number of energy calculations on biomolecules in their environments to be attained, and, more important, via the use of properly optimized parameters in the mathematical models the required chemical accuracy can be achieved. The use of empirical energy functions was initially applied to small organic molecules, where it was referred to as molecular mechanics [4], and more recently to biological systems [2,3]. [Pg.7]

Figure 1 shows schematically the structure of s-trans-1,3-butadicnc. Several studies show that proper geometry parameters are only obtained with a basis set of at least double-f quality, including polarization functions for carbon atoms. Table 1 presents a selection of the results obtained at several levels of calculation, using a basis set of this kind. [Pg.5]

The LC control software, either stand-alone or as part of an overall data-handling system, should be tested by means of a separate OQ protocol. This protocol only needs to address the communica-tions/control integrity of the hardware (e.g., setting up a run/sequence with the proper instrument parameters, the ability to start and stop the pump, etc.). It should cover all the required instrument control functions listed as part of the protocol s functional specifications. It does not need to include specific hardware performance testing, such as linearity or flow rate. The latter tests are performed separately, as part of the individual hardware validation described below. [Pg.310]

Whereas the microprocessor controls an individual basic operation, the central computer, which has all the analytical procedures held in its memory, controls the particular analytical procedure required. At the appropriate time, the central computer transmits the relevant set of parameters to the corresponding units and provides the schedule for the sample-transport operation. All units are monitored to ensure proper functioning. If one of the units signals an error, a predetermined action, such as disposing of the sample, is taken. The basic results from the units are transferred to the central computer, the final results are calculated, and the report is passed to the output terminal. These results can also be transmitted to other data processing equipment for administrative or management purposes. The central control is, therefore, the leading element in a hierarchy of... [Pg.42]

In the derivation of the simplified expressions for solubility and diffusion coefficients, eqs. (4) and (9), C was assumed to be small. This fact does not limit the usefulness of these expressions for high concentrations. We show below that sorption and transport expressions, eqs. (11) and (14), respectively, derived from the simplified equations retain the proper functional form for describing experimental data without being needlessly cumbersome. Of course, the values of the parameters in eqs. (4) and (9) will differ from the corresponding parameters in eqs. (3) and (8), to compensate for the fact that the truncated power series used in eqs. (4) and (9) poorly represent the exponentials when aC>l or 0C>1. Nevertheless, this does not hinder the use of the simplified equations for making correlation between gas-polymer systems. [Pg.121]

Essential progress has been made recently in the area of molecular level modeling of capillary condensation. The methods of grand canonical Monte Carlo (GCMC) simulations [4], molecular dynamics (MD) [5], and density functional theory (DFT) [6] are capable of generating hysteresis loops for sorption of simple fluids in model pores. In our previous publications (see [7] and references therein), we have shown that the non-local density functional theory (NLDFT) with properly chosen parameters of fluid-fluid and fluid-solid intermolecular interactions quantitatively predicts desorption branches of hysteretic isotherms of nitrogen and argon on reference MCM-41 samples with pore channels narrower than 5 nm. [Pg.51]

The non-local density functional theory (NLDFT) with properly chosen parameters of fluid-fluid and fluid-solid intermolecular interactions quantitatively predicts both adsorption and desorption branches of capillary condensation isotherms on MCM-41 materials with the pore sizes from 5 to 10 nm. Both experimental branches can be used for calculating the pore size distributions in this pore size range. However for the samples with smaller pores, the desorption branch has an advantage of being theoretically accurate. Thus, we recommend to use the desorption isotherms for estimating the pore size distributions in mesoporous materials of MCM-41 type, provided that the pore networking effects are absent. [Pg.59]

Quantitation by NMR requires time and skill that the typical organic chemist may lack. Therefore it is desirable to have an internal standard indicator to reveal when proper experimental parameters for quantitation have been employed. The H NMR spectrum of DMFu contains two singlets at 5.80 and 2.20ppm. Gerritz et al. measured the ratio of these two signals as a function of the relaxation delay to provide an internal relaxation standard by whieh to estimate a reasonable experimental time for quantitation. As shown in Table 1.4, quantitation accuracy was within 5% error for several analytes at varying concentrations. [Pg.18]

From symmetry consideration we should choose a proper order parameter for the lower symmetry phase (on account of molecular distribution functions). [Pg.112]

Important Consideration for Proper Functioning of Control Valves Sensors should be installed at appropriate locations in the process unit (raw material feed lines, in the reactors, or in the product lines) for sensing to detect the actual value of the parameter. [Pg.251]

The rate of particle transfer between the boxes determines the rate with which the equilibrium between the boxes is reached. The higher the rate the faster the two phases equilibrate. On the other hand, particles that are in the transition state contribute nonphysically to both boxes at the same time, and one would try to keep their number close to zero during the production run. This tuning is achieved by properly choosing the barrier function parameters. The higher the barrier, the harder is it for the particles to cross from one box to another. [Pg.347]

Setup time is minimal for a handheld IMS detector. It involves inserting the battery pack for power. Detector warmup may run from a few minntes to half an hour. Most current detectors have internal function and parameters checking procedures installed. This self-test feature verifies that proper operational parameters are satisfied before the unit is ready for use. After the warmup, detector calibration can be easily verified with simulants. If verification is successful, the device is ready to detect. [Pg.124]

The question of authority and management is therefore important in a temporary organization as, very often, several independent individuals or structures coexist. When different control structures are shared, it is essential that they ensure the efficient coordination of tasks within the time-frame and budget constraints initially set. The next section is dedicated to another key parameter for the proper functioning of the organization communication. [Pg.527]

By formula (15), (17) and (7) the maximum likelihood function parameters m and can be obtained. According to formula (11) the fatigue life under different stress levels in any survival rate can be calculated properly. [Pg.2173]

There is an ongoing attempt to find a proper function that fits the viscoelastic property data and to calculate the strength of mechanical relaxation and parameters related to relaxation and its distribution. The method used to describe linear viscoelastic behavior by these mathematical models is described in detail in the monograph by Tschoegel [179]. There is an example of the analysis of viscoelastic behavior data obtained using this method where the sol-gel transition of a gellan aqueous solution was the subject [180]. [Pg.321]

The system runs as a standalone application on Win32 platforms (see Fig. 3). Its user interface comprises of a single dialog window which also provides a visual feedback of the system for set-up purposes (checking proper function of the microphone, calibration of parameters, etc.) However, while used in normal operation, the system provides no additional feedback than the one provided by a common mouse. [Pg.493]

After tuning and calibration, the proper functioning of the interface can further be investigated by the injection of a number of standard compounds, e.g. adenosine and tertiary amines, as well as the com-pound(s) of interest. Subsequently, the system can be optimized to achieve the highest response or the best signaTto-noise ratio. Parameters to be studied are the ammonium acetate concentration, the concentrations of the organic modifier and possible other mobile phase additives, the flow-rate, the optimum compound-dependent vaporizer temperature, the source block temperature, the repeller potential, as... [Pg.1190]


See other pages where Proper functions parameter is mentioned: [Pg.598]    [Pg.602]    [Pg.417]    [Pg.595]    [Pg.146]    [Pg.120]    [Pg.3370]    [Pg.450]    [Pg.414]    [Pg.348]    [Pg.246]    [Pg.187]    [Pg.89]    [Pg.204]    [Pg.58]    [Pg.34]    [Pg.741]    [Pg.243]    [Pg.458]    [Pg.15]    [Pg.58]    [Pg.288]    [Pg.76]    [Pg.253]    [Pg.147]    [Pg.866]    [Pg.248]    [Pg.62]    [Pg.163]    [Pg.103]    [Pg.274]    [Pg.134]    [Pg.350]   
See also in sourсe #XX -- [ Pg.293 ]




SEARCH



Functional parameter

Proper

Proper functions

© 2024 chempedia.info