Pressure compensation

The typical operating pressure of filter presses is 600 or 700 kPa, although some manufacturers offer presses for 2000 kPa or higher. As the pressure increases during filtration, it forces the plates apart this maybe offset by a pressure compensation faciHty offered with some large mechanized presses. [Pg.399]

The pressure at which the valve is expected to open (set pressure) is usually selected as high as possible consistent with the effect of possible high pressure on die process as well as the containing vessel. Some reactions have a rapid increase in temperature when pressure increases, and this may fix the maximum allowable process pressure. In other situations the pressure rise above operating must be kept to some differential, and the safety valve must relieve at the peak value. A set pressure at the maximum value (whether maximum allowable working pressure of vessel, or other, but insuring protection to the weakest part of the system) requires the smallest valve. Consult manufacturers for set pressure compensation (valve related) for temperatures >200°F. [Pg.425]

Set Pressure Compensation for Saturated Steam Service Safety-Relief Valves Between Atmospheric ... [Pg.426]

Optical - High accuracy - High price - Limited lifetime (bulb) - Possibility of soiling - Sensitive to changes in air-pressure (compensation) - High power consumption - Re-calibration necessary... [Pg.160]

This component consists of a housing with two fittings for the hose connections to the pressure sensor and to the lower suds container. The inner volume of the component is divided by an elastic membrane with a weight in the middle. A bore in the weight allows for the exchange of air between the chambers. Measuring of the water level is not affected because the bore always allows for pressure compensation. [Pg.188]

Sumetsky, M. Dulashko, Y. Windeler, R. S., Temperature and pressure compensated micro fluidic optical Sensor, In Conference on lasers and electro optics quantum electronics and laser science conference and photonic applications systems technologies, OS A Technical Digest (CD), Optical Society of America, 2008, paper CMJ6... [Pg.376]

The main problem, the height-dependent differential pressure between the catho-lyte gap and oxygen across the ODC, could be solved with the pressure compensation system based on oxygen supply via gas pockets [1] (see Fig. 4.2). The first successful piloting was done in October 1995 on the basis of Bayer engineering and construction. In a four-gas-pocket element with each electrode segment of 180 x 180 mm2 individually supplied with power, the proper function of pressure compensation could be proven for a total height of 90 cm. [Pg.63]

Fig. 4.2 The effect of pressure compensation in chlor-alkali electrolysis. Fig. 4.2 The effect of pressure compensation in chlor-alkali electrolysis.
For HCI electrolysis the cathodic reaction product is water, which is easily drained through the ODC without affecting the membrane water content. Consequently, the ODC can be attached directly to the membrane and pressure compensation is not necessary. The cell concept, which was developed in another co-operation with DeNora, could not be simpler - the basic cell principle is shown in Fig. 4.6. Initial laboratory tests conducted in 1994 at Bayer on the basis of old GE developments [4] demonstrated the feasibility of HCI electrolysis with ODC and the potential for a reduction of the cell voltage to about one-third of present values. [Pg.67]

The reaction conditions chosen for the in situ IR studies are often much milder (25-100 °C, 100 bar) than the process conditions (140 °C, 250 bar), which may not affect the equilibria, as the higher pressure compensates for the higher temperature. The relative rate, however, of isomerisation of 1-alkenes may increase dramatically between room temperature and 140 °C. [Pg.133]

The partial derivatives are usually assumed to be constants that are evaluated at the steadystate operating level from the vapor-liquid equilibrium data. Thus, pressure and temperature on a tray can be measured, as shown in Fig. 8.3c, and a composition signal or pressure-compensated temperature signal generated and controlled. [Pg.257]

For these reasons an intermediate tray is selected down the column where the temperature profile begins to break. Pressure compensation of the temperature signal should be used if column pressure or pressure drop varies significantly. [Pg.269]

A 500 ml., three-necked, round-bottomed flask is equipped with a Trubore stirrer, a pressure-compensating dropping funnel, and a reflux condenser with drying tube. The flask is charged with 144 g. of triphenylphosphine (0.55 mole) (Note 1) and 125... [Pg.4]

These modern computer controlled ignition systems use multiple sensors to determine optimum firing. This may include double pick-up sensors on the flywheel to determine rpms under acceleration and deceleration, intake and atmospheric pressure compensation, oxygen sensor levels to maximize combustion, temperature sensors and exhaust emission sensors. All this data is constantly fed into the on-board computer and processed using complex algorithms to determine optimum firing and fuel consumption levels. [Pg.51]

Differential pressure meters are widely used. Temperature, pressure, and density affect gas density and readings of differential pressure meters. For that reason, many commercial flowmeters that are based on measurement of differential pressure often have integral temperature and absolute pressure measurements in addition to differential pressure. They also frequently have automatic temperature and pressure compensation. [Pg.14]

For osmotic equilibrium, the chemical potential of the solvent must be the same on both sides of the membrane. In the two-dimensional analog also the chemical potential must be the same for the water on both sides of the float. The presence of the solute lowers the chemical potential of the solvent, but the excess pressure compensates for this. Therefore, by analogy with Equation (3.19), we write... [Pg.315]

Wrong The chief engineer failed to realize that the vacuum pressure indicator was not equipped with a barometric pressure compensator. An ordinary vacuum pressure indicator or pressure gauge reads the pressure difference between the vacuum system and atmospheric pressure. When ambient temperatures drop, the barometer rises or ambient pressure goes up. An ordinary vacuum pressure gauge or indicator would then read an improved vacuum. But in reality, the vacuum has not changed. [Pg.65]

The greatest impact of the Clark oxygen electrodes has been in medicine and physiology. (A schematic diagram of a catheter-size Clark electrode is shown in Fig. 7.7.) On the other hand, a temperature- and pressure-compensated Clark electrode for oceanographic measurements up to 600 ft has also been developed (Fatt, 1976). The normal temperature coefficient of the Clark electrode is 2%/°C... [Pg.212]

Addition of carbanions - syntheses of tert-butyl-H-SWCNTs and of tert-butyl-SWCNTs In a nitrogen-purged flask, equipped with a gas inlet and a pressure compensator, 20 mg of HiPCO tubes (1.7 mmol of carbon) was dispersed in 50 mL of anhydrous benzene. To this dispersion 2.5 mL of a 1.7 M solution of tert-butyllithium (4.25 mmol) in hexane were added dropwise over a period of 10 min. Subsequently, the suspension was additionally stirred for 1 h at room temperature and the SWCNT dispersion turned into a black homogeneous solution. The solution was stirred for a further 1 h and subsequently quenched by the addition of... [Pg.47]


See other pages where Pressure compensation is mentioned: [Pg.750]    [Pg.2336]    [Pg.219]    [Pg.88]    [Pg.214]    [Pg.502]    [Pg.25]    [Pg.65]    [Pg.65]    [Pg.136]    [Pg.257]    [Pg.122]    [Pg.204]    [Pg.204]    [Pg.224]    [Pg.67]    [Pg.496]    [Pg.75]    [Pg.49]    [Pg.111]    [Pg.180]    [Pg.44]    [Pg.46]    [Pg.73]    [Pg.942]   
See also in sourсe #XX -- [ Pg.52 ]

See also in sourсe #XX -- [ Pg.14 ]

See also in sourсe #XX -- [ Pg.555 , Pg.557 , Pg.562 , Pg.563 , Pg.566 , Pg.682 ]

See also in sourсe #XX -- [ Pg.114 , Pg.124 , Pg.125 , Pg.215 , Pg.263 , Pg.325 , Pg.326 , Pg.327 , Pg.328 , Pg.329 , Pg.330 , Pg.331 , Pg.332 , Pg.333 , Pg.334 , Pg.335 , Pg.336 , Pg.337 , Pg.338 , Pg.339 , Pg.340 , Pg.341 ]




SEARCH



Barometric pressure compensation

Barometric pressure compensator

Control and Compensating Pressure Tap Locations

Employer responses to compensation pressures

Pressure Compensation of Distillation Tray Temperature

Pressure-compensated temperature

Pressure-compensated temperature INDEX

Pressure-compensated temperature control

Pressurization leakage compensation

Temperature measurement pressure-compensated