Monitor exterior wall temperature with infrared optical detection system, and operating instructions for operator response if high temperature signal occurs... [Pg.58]

The fact is, that the human hand is not a good thermometer and it can give false temperature signals. In studies of human touch defining hot , hot varies somewhere between 120° and 130° F, depending on the individual. The human hand is worthless above this arbitrary point to estimate temperature. [Pg.165]

For hot water boilers the burner controls will be similar but controlled by a combination of pressure and temperature signals. A single overriding level control will be fitted to the flooded boiler to protect against any accidental low-water condition. [Pg.365]

As indicated above, the Model 611 does not require a separate temperature probe and so it has no temperature knob to be operated its circuits instead perform the following functions (abbreviated as in the Orion specification) (1) induce ac signal across pH probe (2) measure average dc potential of probe (3) convert amplitude of ac signal to dc potential (V) (4) calculate log V (5) measure in-phase ac current through probe (6) convert current to dc potential proportional to current (/) (7) calculate log / (8) calculate log R (resistance of probe) = log V - log I (9) convert log R into signal proportional to temperature (displayed) (10) use temperature signal to correct pH, to be read. [Pg.97]

In solution, certain complexes are observed to undergo an envelope-flip from one face of the diene ligand to the other. The XH NMR spectra of Cp2Zr(s-cis diene) complexes (11 R = R" = H) at ambient temperatures indicate a fluxional process which equilibrates the Cp signals as well as the terminal protons (equation 4). At lower temperature, signals for a... [Pg.896]

The sample of desorbed tritide is placed inside a quartz tube that is connected to a gas-handling manifold by a TorrSeal . A quartz sleeve with Silicon Carbide (SiC) in the annular space is placed around the end of the quartz tube, surrounding the sample with microwave susceptor. The quartz tube and susceptor sleeve are thermally insulated from the rest of the microwave cavity. An internal thermocouple measures the temperature of the sample and provides the temperature signal for process control of the desired temperature. A shine block (alumina foam), attached to the thermocouple, blocks radiant heating of the TorrSeal and the upper area of the quartz tube and manifold. An IR pyrometer is used as a secondary measure of the temperature of the susceptor, and therefore of the sample. A stainless steel shield reflects microwaves from the quartz tube not in the susceptor sleeve, eliminating the production of a plasma at low pressure in the quartz tube. [Pg.212]

The converted temperature signal serves as input to the digital PID temperature controller so that the temperature control loop is closed (see Sect. 6.3.3 for a detailed description of the temperature control loop). [Pg.98]

The partial derivatives are usually assumed to be constants that are evaluated at the steadystate operating level from the vapor-liquid equilibrium data. Thus, pressure and temperature on a tray can be measured, as shown in Fig. 8.3c, and a composition signal or pressure-compensated temperature signal generated and controlled. [Pg.257]

For these reasons an intermediate tray is selected down the column where the temperature profile begins to break. Pressure compensation of the temperature signal should be used if column pressure or pressure drop varies significantly. [Pg.269]

When a solid sample of A-acetylproline is dissolved at — 60°C in CD3OD, the H-NMR signals of only one species are observed (72CC788) whereas if the sample is allowed to reach room temperature, signals from a second con-... [Pg.139]

XPS has been used by Inoue and Yasumori (425a) to study the surface of MgO, CaO, and BaO after exposure to water vapor followed by in situ dehydration at various temperatures. Signals attributed to O2- lattice ions were observed after all treatments with peaks at 531.6 (MgO), 529.6 (CaO), and 528.5 (BaO) eV. Immediately after hydration, a second series of peaks at 533.7 (MgO), 532.2 (CaO), and 532.1 (BaO) eV were observed, which progressively disappeared as the dehydration temperature increased these were assigned to OH- ions. In addition, peaks at 532.1 (CaO) and 530.6 (BaO) eV which appeared during dehydration were assigned to O- ions formed from the following reaction ... [Pg.109]

These tests check the integrity of measurement chains between the sensor and the equipment as well as along the measurement chain. For example, a temperature signal carried over by a current loop is checked against the exact temperature level and the exact conversion levels on the current loop. However, if the temperature sensor contains its own local temperature indicator, this indication will be compared to the temperature available on the control system. [Pg.426]

This instrument utilises a silver block chamber with an external heater. The chamber contains a constantan disc with raised platforms for the sample and reference containers. The temperature difference between sample and reference is monitored by area thermocouples formed by the constantan disc and chromel wafers under the platforms. Amplification and electronic compensation of the differential temperature signal provides a linear calorimetric response over a wide temperature range. The theory of this instrument is discussed by Lee and Levy 6). Other available examples of... [Pg.113]

Figure 6.9 shows an ordinary thermowell-and-thermocouple assembly. The thermocouple junction consists of two wires of different metals. When this junction of the wires is heated, a small electric current, proportional to the junction temperature, is produced. Different metal wires make up the three most common junctions J, H, and K. It is not uncommon for a thermocouple, regardless of the type of junction, to generate too low a temperature signal. [Pg.70]

If two temperature readings from the same point in the process disagree, the chances are that a temperature indication is more accurate than a temperature-control signal. The temperature signal used for control has usually been converted from its direct milliamp output to operate a control station. The temperature indication is generated right from the junction of the thermocouple, and hence there is less chance for error. [Pg.72]

Fig. 46. 19F NMR signals of 1,1-difluorocyclohexane at various temperatures signals of a equatorial and b axial fluorine atoms... Fig. 46. 19F NMR signals of 1,1-difluorocyclohexane at various temperatures signals of a equatorial and b axial fluorine atoms...
One important difficulty is that the noise of the temperature signal in the industrial environment is amplified by the derivation, which is at the cost of the accuracy of the method. These criteria give an alarm between 20 and 60 minutes before mnaway [16], which is a short time, that is, the runaway is well-developed when the alarm is activated. [Pg.251]

Strong A.E. Kearns E.J. and Gjovig K.K. (2000). Sea surface temperature signals from satellites update. Geophys. Res. Lett., 27(11), 1667-1670. [Pg.553]

By diluting a reactive sample powder with an inert powder (e.g. AI2O3), the heat capacity of the sample can be made to match more closely that of the reference, hence baseline float can be dampened. This is a useful technique for reactions of significant thermal effect, e.g. combustion, since sample dilution diminishes the intensity of the differential temperature signal. Since the diluent adds a thermal resistance between the reaction zones and the temperature measuring device, the onset of reactions will shift to higher temperatures. [Pg.75]

The plant is equipped with an Eurotherm T100 process control system. 21 control circuits, 44 temperature signals, 4 level indications, 4 pressure signals, 4 mass flow indications, 4 pumps and 12 control valves are processed, regulated and indicated with a computer system. Samples can be withdrawn from all important pipes and all column insertion sections. [Pg.625]

Interpret the two 13C EXSY spectra on the following page. The solutions only differ significantly in their temperature. Signals from free ligand are marked L, and those from the complex are marked C. [Pg.41]

Most recently an analysis technique was developed which allows measurement of tablet temperature directly after ejection of the tablet on the machine (Figure 11) by an infrared sensor [85], The temperature signal can be directly related to force and displacement measurement. [Pg.1069]

In attempts to overcome the problem of flat temperature profiles, differential temperature has been used in some systems. Looking at the difference in temperature between two trays helps to reduce the influence of pressure on the temperature signals. However, it does not handle changes in pressure drop. [Pg.213]

Standard RTD Serial Number standard RTD Temperature Signal Output (mA) Temp. Output Equiv. (°C) Error (T) Pass/Fail... [Pg.260]

At low temperatures, signals at 1.15 and 1.30 ppm (overlappedwith the T7 CH, and T3 CH, peaks) attributable to the methyl groups from the free ligand and bound ligand, respectively, are distinguishable. As the temperature is increased, a broad peak appears between these two signals (at — 1.22 ppm). At the lower temperatures < (vg - i/p), so that... [Pg.542]


See other pages where Temperature signal is mentioned: [Pg.549]    [Pg.192]    [Pg.123]    [Pg.230]    [Pg.308]    [Pg.301]    [Pg.198]    [Pg.894]    [Pg.193]    [Pg.257]    [Pg.86]    [Pg.39]    [Pg.139]    [Pg.80]    [Pg.339]    [Pg.356]    [Pg.83]    [Pg.1609]    [Pg.201]    [Pg.246]    [Pg.127]    [Pg.108]    [Pg.258]    [Pg.214]    [Pg.2146]   