Rapid-Scan Corrosion Behavior Diagram (CBD) Basically, all the same equipment used in the conductance of an ASTM G5 slow-scan polarization study is used for rapid-scan CBDs (that is, a standard test cell, potentiostat, voltmeters, log converters, X-Y recorders, and electronic potential scanning devices). The differences... [Pg.2431]

With increasing distance from the crossing or the proximity of the tramway rails, the stray currents absorbed in the pipeline emerge again. The current exit occurs mainly at crossings with other tramway tracks. In addition to potentiostatic control, a basic current adjustment is necessary. [Pg.362]

The potentiostatic technique discussed here involves the polarisation of a metal electrode at a series of predetermined constant potentials. Potentio-stats have been used in analytical chemistry for some time Hickling was the first to describe a mechanically controlled instrument and Roberts was the first to describe an electronically controlled instrument. Greene has discussed manual instruments and basic instrument requirements. [Pg.1107]

Fig. 19.36 Basic circuit for a poiemiostat. (a) Basic circuit for a potentiostat and electrochemical cell, (b) Equivalent circuit, (c) Circuit of a basic potentiostat. A.E. is the auxiliary electrode, R.E. the reference electrode and W.E. the working electrode (6 and c are from Polen-tiostat and its Applications by J. A. von Fraunhofer and C. H. Banks, Butlerworths (1972))... Fig. 19.36 Basic circuit for a poiemiostat. (a) Basic circuit for a potentiostat and electrochemical cell, (b) Equivalent circuit, (c) Circuit of a basic potentiostat. A.E. is the auxiliary electrode, R.E. the reference electrode and W.E. the working electrode (6 and c are from Polen-tiostat and its Applications by J. A. von Fraunhofer and C. H. Banks, Butlerworths (1972))...
Figure 19.36c shows a basic circuit of a potentiostat in which the difference between the desired potential (Fj) and the actual potential of the working... [Pg.1108]

The basic instrumentation required for controlled-potential experiments is relatively inexpensive and readily available commercially. The basic necessities include a cell (with a three-electrode system), a voltammetric analyzer (consisting of a potentiostatic circuitry and a voltage ramp generator), and an X-Y-t recorder (or plotter). Modem voltammetric analyzers are versatile enough to perform many modes of operation. Depending upon the specific experiment, other components may be required. For example, a faradaic cage is desired for work with ultramicroelectrodes. The system should be located in a room free from major electrical interferences, vibrations, and drastic fluctuations in temperature. [Pg.100]

Two transient techniques (galvanostatic and potentiostatic) have been presented in each of these either current or potential, respectively, is kept constant during the observed variation of the other. It is hardly surprising, therefore, to discover that, since the 1950s, it has been the practice of many electrochemists to vary current and potential at the same time. The basic technique is called linear... [Pg.705]

As will be seen, the rate at which the potential is changed (i.e., the sweep rate) becomes veiy important. For complex reactions, it may have to be so slow (0.01 mV s 1) that cyclic voltammetry approaches a potentiostatic (rather than a potentiody-namic) technique. On the other hand, too large a sweep rate may yield parameters that are not those of the steady state and hence are difficult to fit into a mechanism of consecutive reactions in which the attainment of a steady state (d6/dt = 0) at each potential is a basic assumption. Thus, determining the mechanisms of reactions that are to function in steady-state devices such as fuel cells or reactors is more likely to... [Pg.709]

The potential step provides the theoretical background for any potentiostatic regulation experiment and a basic understanding is necessary for the mathematical solution of any controlled potential, nonsteady-state voltammetric response, such as LSV, pulse or a.c. experiments. At a stationary electrode, the current response to a potential step is described by the Cottrell equation [eqn. (83)] but at hydro-dynamic electrodes, it needs to be modified to take account of forced convection. [Pg.427]

The arrival of large-scale integrated circuits in the last 20 years has revolutionized chemical instrumentation just as it has kitchens, automobiles, and television sets. With respect to electrochemistry, the microprocessor has been incorporated in signal generation and data processing, while the basic instrumentation (e.g., potentiostat and current-to-voltage converter) remains as described in earlier sections of this chapter. Microprocessor instruments provide flexibility... [Pg.189]

Instrumentation for selected aspects of electroanalytical chemistry is covered in Chapters 6-8. Although computers have made a tremendous impact on electroanalytical instrumentation, many aspects of these chapters are timeless. The basic configurations of a potentiostat have not changed since the early 1960s, although the electronic components themselves are dramatically different Learn to build your own potentiostat in Chapter 6, then see how to fine-tune it in Chapter 7. [Pg.966]

Figure 1 shows a schematic diagram of the basic SECM instrument employing an amperometric microprobe. An UME tip is attached to a three-dimensional (3D) piezo positioner controlled by a computer, which is also used for data acquisition. A bipotentiostat (i.e., a four-electrode potentiostat) controls the potentials of the tip and/or the substrate versus the reference electrode and... [Pg.179]

In most electrochemical measurements of corrosion kinetics a potentiostat is used. This description will cover the rudimentary operation of a potentiostat using the concept of an ideal operational amplifier (op amp) as a basis. An op amp is a three-terminal device as shown in Fig. 16 with two input terminals and one output terminal. A perfect op amp follows five basic rules (19) ... [Pg.30]

Although electrochemical characterizations have recently been performed on single intercalation particles, in most cases composite powdery electrodes containing a mixture of intercalation particles, electrically conductive additives (e.g., carbon black) and PVDF binder have also been used. In order to obtain consistent results and to reach comprehensible intercalation mechanisms in these electrodes, basic electroanalytical characterizations such as slow-scan rate -> cyclic voltammetry (SSCV), -> potentiostatic intermittent titration (PITT) (or -> galvanostatic intermittent titration, GITT), and -> electrochemical impedance spectroscopy (EIS) should be applied in parallel or in a single study. [Pg.354]

Basically, experimental approaches to ion transfer kinetics rely on classical galvanostatic [152] or potentiostatic [146] techniques, such as chronopotentiometry [118, 138], chronocoulometry [124], cyclic voltammetry [146], convolution potential sweep voltammetry [147], phase selective ac voltammetry [142], or equilibrium impedance measurements [148]. These techniques were applied mostly to liquid-liquid interfaces with a macroscopic area (typically around 0.1 cm ). However, microelectrode methodology has been successfully introduced into liquid-liquid electrochemistry as a novel electroanalytical tool by Senda and coworkers [153] and... [Pg.329]

The reactions observed for the dimer complex adsorbed in a Nafion film coated on an ITO electrode at different pH by in situ absorption spectral measurements are summarized as shown in Fig. 11. At higher positive potentials and at potentiostatic conditions, a band at around 450 nm was observed indicating the formation of H20-Ru "-Ru -OH2 at acidic conditions and formation of H20-Ru" "-Ru -OH at basic conditions in addition to the absorbance at 655 nm. This shows that during the catalytic water oxidation process, the diaquo dimer complex exists as an intermediate. In a Nafion polymer membrane, the metal complex is isolated and experiences a micro-heterogeneous environment imposed by hydrophobic fluorocarbon moiety and... [Pg.232]

The study of aqueous corrosion of ion-bombarded samples requires electrochemical equipment. The basic technique is the measurement of potentiostatic current-potential relations. A more elaborate set-up allows potentiostatic and galva-nostatic measurements and also investigations with very short current pulses. Fig. 26 shows a schematic lay-out of a rather universal arrangement... [Pg.44]

A basic voltametric instrument consists of a cell, a potentiostat, and a recorder. Chemical reactions are caused by applying a potential to an electrode in a cell. The current, which flows under the experimental conditions, is monitored with the recorder. The cell generally consists of three electrodes placed in seawater (1) the working electrode, usually a hanging drop of Hg or a Hg-plated graphite or glassy-carbon surface (2) the reference electrode, made of either calomel or Ag wire anodized to form AgCl and (3) a counterelectrode made of pure Pt wire. [Pg.140]

Yet when applied to current reversal techniques, such as double-step chronampero-metry of cyclic voltammetry, these methods require that an appreciable current be observed during the backward perturbation, that is, for t > 0, in potentiostatic methods or after the potential scan inversion in cyclic voltammetry. This requires that the characteristic time 0 of the method is adjusted to match the half-life ti/2 of the electrogenerated intermediate. Today, owing to the recent development of ultramicroelectrodes, 0 can be routinely varied from a few seconds to a few nanoseconds [102]. Yet with basic standard electrochemical equipment, 0 is usually restricted from the second to the low millisecond range. Thus for experimental situations involving faster chemical reactions, current rever-... [Pg.88]

Remember 6.2 A basic potentiostat can consist of two operational amplifiers one to control potential and one to follow current. [Pg.103]

Remember 6.3 A basic potentiostat for impedance measurements requires a voltage adder to superimpose the sinusoidal signal onto an imposed potential. [Pg.104]

Vesala, A., and Saloma, E., 1977, Determination of basicity constants by potentiostatic titration Finnish Chemical Letters, p. 160-163. [Pg.466]

The basic components of a modem electroanalytical system for voltammetry are a potentiostat, computer, and the electrochemical cell. In some cases, the potentiostat and the computer are bundled into one package, whereas in other systems the computer and the A/D and D/A converters and microcontroller are separate, and the potentiostat can operate independently. [Pg.267]


See other pages where Potentiostat basics is mentioned: [Pg.2431]    [Pg.91]    [Pg.16]    [Pg.20]    [Pg.79]    [Pg.12]    [Pg.330]    [Pg.42]    [Pg.47]    [Pg.398]    [Pg.730]    [Pg.176]    [Pg.94]    [Pg.294]    [Pg.142]    [Pg.367]    [Pg.12]    [Pg.2186]    [Pg.536]    [Pg.136]    [Pg.1517]    [Pg.86]    [Pg.2696]   