Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Phase special

Again, helium degassing as described above is an appropriate way to remove oxygen, especially when combined with heating (40 to 50°C) of the mobile phase. Special care must be taken that oxygen cannot diffuse back into the mobile phase replace PTFE tubing by steel tubing between mobile phase container and pump, and between column and detector. [Pg.49]

The progression of the cell cycle is regulated by interconversion processes, in each phase, special Ser/Thr-specific protein kinases are formed, which are known as cyclin-depen-dent kinases (CDKs). This term is used because they have to bind an activator protein (cyclin) in order to become active. At each control point in the cycle, specific CDKs associate with equally phase-specific cyclins. if there are no problems (e.g., DNA damage), the CDK-cyclin complex is activated by phosphorylation and/or dephosphorylation. The activated complex in turn phosphorylates transcription factors, which finally lead to the formation of the proteins that are required in the cell cycle phase concerned (enzymes, cytoskeleton components, other CDKs, and cyclins). The activity of the CDK-cyclin complex is then terminated again by proteolytic cyclin degradation. [Pg.394]

Analysis of variance (ANOVA) analyses were performed using the general statistical package StatView 5.01 (SAS Institute, Cary, NC, USA). The ANOVAs were calculated as repeated-measures ANOVAs with wells as within factor for phase 1 and with plates as within factor for subsequent phases. Specialized statistics, such as comparison of fits of different calibration curves, were calculated in MATLAB 5.1 (MathWorks, Natick, MA, USA) using custom routines. [Pg.43]

In summary, an attempt has been made in sections 5.2 and 5.3 to provide a number of formulations for the thermodynamic properties of surface phases. Special emphasis has been placed on the key role of the Gibbs adsorption equation as a link between the experimentally available isotherm data, and the determination of molar or differential entropies, enthalpies,... [Pg.482]

The columns used for the separation of phenolic acids are mainly reversed phase (RP), other sihca-based chemically bound phases, and non-silica polymers or mixed inorganic-organic phases. Special silica sorbents with reduced metallic residue contents and minimum residual silanol groups on the surface could positively influence peak symmetry without the strict demands for the successful separation of acidic analytes. Almost exclusively, RP C18 phases ranging from 100 to 250 mm in length and usually with an internal diameter of 3.9 to 4.6 mm are recommended. Particle sizes are in the range of 3-10 pm. Short 50- 100-mm columns with 3-pm particles have also been tested for fast phenolic acid separations. Narrow bore columns (internal diameter 2 mm) are recommended especially for HPLC-MS applications.Some problems could arise with the applications of narrow or microbore columns in the direct injections of plant extracts there is the possibility of plugging the column after repeated injections. In these cases, an additional clean-up step has to be applied instead of just the simple extraction... [Pg.1165]

The chapter is organized to cover all important processes leading to deactivation of an excited state in a condensed phase. Special attention has been given to the various fullerenes because of the exceptionally high interest paid to these compounds over the last few years. Other sections consider theoretical concepts, instrumental methods for monitoring photophysical processes, and applications. [Pg.17]

C. J. Welch, M. N. Protopopova and G. A. Baht, Microscale synthesis and screening of combinatorial libraries of new chromatographic stationary phases (Special Publication), Royal Society of Chemistry, 235 (1999), 129-138. [Pg.282]

Acids The column is less critical compared to bases, a good (not endcapped) Cjg would be adequate Note. Many stationary phases specially produced for bases are not suitable for use with acids. Acetate, perchloric acid, phosphoric acid or phosphate buffer pH 2 3, PIC A reagents. [Pg.120]

The natural choioe of a sqMuation technique for both inorganic cations and anions is icm-exdiangB duomatography. The standard detection technique for these analytes is conductivity detection. This requires a low background conductance of the mol phase. Special techniques have been developed under the name of i< i diromatograpby that combine spedal low-capadty ion exchangers with special mobile phases. For many analytical proble cookbook methods have been worked out by the su q>Iiers of ion-chromatography equipment Therdore there is usually little need to develop new methods. [Pg.75]

QA is responsible for auditing computer-related systems that are used in GxP environments in order to assess adherence to policies and procedures. The frequency of the audits should preferably be related to experiences during previous audits (in the same discipline and/or of the same or similar systems). For systems in the operational phase, special attention should be given to the change control process, including the relevant documentation and training. [Pg.373]

The follow-up should be focused on the possible complications and clinical outcome (Table 4.3). In the acute and immediate post-procedural phase, special attention should be directed to the early detection of sequelae of non-target embolization, which can often result in major complications. It is a good practice to routinely conduct a telephone interview with the patient no later than a week after the procedure. Modern interventionists are clinical providers and an interventional clinic followup at an appropriate period of time following a major embolization procedure is not an option but a required minimal standard of practice. [Pg.45]

The chromatographic system should comprise a precolumn located between the pump and the injector, packed with silica gel, in order to saturate the mobile phase with silicic acid, thus increasing the lifetime of the analytical column. Caution must be taken to insure that the steady-state condition required for reproducible chromatography is reached. Before the sample is injected into the chromatograph, the system must be equilibrated with the micellar mobile phase. Special care is required to work with micellar mobile phases such as those given in Chapter 4 (Section IV). [Pg.344]

Table 3 OH-terminated silphenylene/siloxane copolymer phases, specially designed for high-temperature work... Table 3 OH-terminated silphenylene/siloxane copolymer phases, specially designed for high-temperature work...
Manufacturing History. As pointed out in Sec. 6.1.4, because of the high viscosity and high volatility of silica (SiOj) at the temperatures needed to melt its crystalline phases, specialized techniques are required to prepare silica glass products. Some key highlights in process evolution include ... [Pg.439]


See other pages where Phase special is mentioned: [Pg.139]    [Pg.184]    [Pg.204]    [Pg.128]    [Pg.162]    [Pg.35]    [Pg.83]    [Pg.132]    [Pg.1801]    [Pg.2070]    [Pg.1759]    [Pg.7962]    [Pg.604]    [Pg.525]    [Pg.30]    [Pg.471]    [Pg.548]   


SEARCH



Mobile phase special additives

Special Additives in Mobile Phase

Special LDA-Systems for Two-Phase Flow Studies

Special Polymer Melt Phase Distributions

© 2024 chempedia.info