Spectrometric Analysis. Remarkable developments ia mass spectrometry (ms) and nuclear magnetic resonance methods (nmr), eg, secondary ion mass spectrometry (sims), plasma desorption (pd), thermospray (tsp), two or three dimensional nmr, high resolution nmr of soHds, give useful stmcture analysis information (131). Because nmr analysis of or N-labeled amino acids enables determiaation of amino acids without isolation from organic samples, and without destroyiag the sample, amino acid metaboHsm can be dynamically analy2ed (132). Proteia metaboHsm and biosynthesis of many important metaboUtes have been studied by this method. Preparative methods for labeled compounds have been reviewed (133). [Pg.285]

Brown,]. A., Kunz, F.W., and Belitz, R. K. (1991). Characterization of automotive catalysts using inductively coupled plasma mass spectrometry Sample preparation.J. /4 [Pg.199]

Douglas, D. J. and Kerr, L. A. (1988) Study of solids deposition on inductively coupled plasma mass spectrometry samples and skimmers. J. Anal At. Spectrom., 3,749-52. Rosman, K. J. R. and Taylor, R D. P. (1997) lUPAC Isotopic Composition of the Elements. Available from http //www.iupac.org/reports/1998/7001rosman/iso.pdf. [Pg.431]

Particularly in mass spectrometry, where discharges are used to enhance or produce ions from sample materials, mostly coronas, plasmas, and arcs are used. The gas pressure is normally atmospheric, and the electrodes are arranged to give nonuniform electric fields. Usually, coronas and plasmas are struck between electrodes that are not of similar shapes, complicating any description of the discharge because the resulting electric-field gradients are not uniform between the electrodes. [Pg.38]

If a sample solution is introduced into the center of the plasma, the constituent molecules are bombarded by the energetic atoms, ions, electrons, and even photons from the plasma itself. Under these vigorous conditions, sample molecules are both ionized and fragmented repeatedly until only their constituent elemental atoms or ions survive. The ions are drawn off into a mass analyzer for measurement of abundances and mJz values. Plasma torches provide a powerful method for introducing and ionizing a wide range of sample types into a mass spectrometer (inductively coupled plasma mass spectrometry, ICP/MS). [Pg.87]

To examine a sample by inductively coupled plasma mass spectrometry (ICP/MS) or inductively coupled plasma atomic-emission spectroscopy (ICP/AES) the sample must be transported into the flame of a plasma torch. Once in the flame, sample molecules are literally ripped apart to form ions of their constituent elements. These fragmentation and ionization processes are described in Chapters 6 and 14. To introduce samples into the center of the (plasma) flame, they must be transported there as gases, as finely dispersed droplets of a solution, or as fine particulate matter. The various methods of sample introduction are described here in three parts — A, B, and C Chapters 15, 16, and 17 — to cover gases, solutions (liquids), and solids. Some types of sample inlets are multipurpose and can be used with gases and liquids or with liquids and solids, but others have been designed specifically for only one kind of analysis. However, the principles governing the operation of inlet systems fall into a small number of categories. This chapter discusses specifically substances that are normally liquids at ambient temperatures. This sort of inlet is the commonest in analytical work. [Pg.103]

The nebulization concept has been known for many years and is commonly used in hair and paint spays and similar devices. Greater control is needed to introduce a sample to an ICP instrument. For example, if the highest sensitivities of detection are to be maintained, most of the sample solution should enter the flame and not be lost beforehand. The range of droplet sizes should be as small as possible, preferably on the order of a few micrometers in diameter. Large droplets contain a lot of solvent that, if evaporated inside the plasma itself, leads to instability in the flame, with concomitant variations in instrument sensitivity. Sometimes the flame can even be snuffed out by the amount of solvent present because of interference with the basic mechanism of flame propagation. For these reasons, nebulizers for use in ICP mass spectrometry usually combine a means of desolvating the initial spray of droplets so that they shrink to a smaller, more uniform size or sometimes even into small particles of solid matter (particulates). [Pg.106]

Samples to be examined by inductively coupled plasma and mass spectrometry (ICP/MS) are commonly in the form of a solution that is transported into the plasma flame. The thermal mass of the flame is small, and ingress of excessive quantities of extraneous matter, such as solvent, would cool the flame and might even extinguish it. Even cooling the flame reduces its ionization efficiency, with concomitant effects on the accuracy and detection limits of the ICP/MS method. Consequently, it is necessary to remove as much solvent as possible which can be done by evaporation off-line or done on-line by spraying the solution as an aerosol into the plasma flame. [Pg.137]

The previous discussion has centered on how to obtain as much molecular mass and chemical structure information as possible from a given sample. However, there are many uses of mass spectrometry where precise isotope ratios are needed and total molecular mass information is unimportant. For accurate measurement of isotope ratio, the sample can be vaporized and then directed into a plasma torch. The sample can be a gas or a solution that is vaporized to form an aerosol, or it can be a solid that is vaporized to an aerosol by laser ablation. Whatever method is used to vaporize the sample, it is then swept into the flame of a plasma torch. Operating at temperatures of about 5000 K and containing large numbers of gas ions and electrons, the plasma completely fragments all substances into ionized atoms within a few milliseconds. The ionized atoms are then passed into a mass analyzer for measurement of their atomic mass and abundance of isotopes. Even intractable substances such as glass, ceramics, rock, and bone can be examined directly by this technique. [Pg.284]

All three types of discharge involve the formation of ions as part of the process. For various reasons, most of the ions are positive. The ions can be examined by mass spectrometry. If small amounts of a sample substance are introduced into a corona or plasma or arc, ions are formed by the electrons present in the discharge or by collision with ions of the discharge gas. [Pg.388]

Samples to be examined by inductively coupled plasma and mass spectrometry (ICP/MS) are frequently in the form of a solution of an analyte in a solvent that may be aqueous or organic. [Pg.399]

Gold is a useflil caUbration standard for this method (see Radioactive tracers). Whereas similar sensitivities can be achieved by inductively coupled plasma mass spectrometry (qv), the latter requires more extensive sample preparation to overcome interference by other metals such as copper (64). [Pg.381]

Analyses of alloys or ores for hafnium by plasma emission atomic absorption spectroscopy, optical emission spectroscopy (qv), mass spectrometry (qv), x-ray spectroscopy (see X-ray technology), and neutron activation are possible without prior separation of hafnium (19). Alternatively, the combined hafnium and zirconium content can be separated from the sample by fusing the sample with sodium hydroxide, separating silica if present, and precipitating with mandelic acid from a dilute hydrochloric acid solution (20). The precipitate is ignited to oxide which is analy2ed by x-ray or emission spectroscopy to determine the relative proportion of each oxide. [Pg.443]

The very low Hg concentration levels in ice core of remote glaciers require an ultra-sensitive analytical technique as well as a contamination-free sample preparation methodology. The potential of two analytical techniques for Hg determination - cold vapour inductively coupled plasma mass spectrometry (CV ICP-SFMS) and atomic fluorescence spectrometry (AFS) with gold amalgamation was studied. [Pg.171]

The complex of the following destmctive and nondestmctive analytical methods was used for studying the composition of sponges inductively coupled plasma mass-spectrometry (ICP-MS), X-ray fluorescence (XRF), electron probe microanalysis (EPMA), and atomic absorption spectrometry (AAS). Techniques of sample preparation were developed for each method and their metrological characteristics were defined. Relative standard deviations for all the elements did not exceed 0.25 within detection limit. The accuracy of techniques elaborated was checked with the method of additions and control methods of analysis. [Pg.223]

The liquid chromatography - tandem mass spectrometry (LC/MS/MS) technique was proposed for the determination of corticosteroids in plasma and cerebrospinal fluid (CSF, liquor) of children with leucosis. Preliminai y sample prepai ation included the sedimentation of proteins, spinning and solid-phase extraction. MS detection was performed by scanning selected ions, with three chai acteristic ions for every corticosteroids. The limit of detection was found 80 pg/ml of plasma. [Pg.351]

Inductively coupled plasma-mass spectrometry (ICP-MS) is a multielement analytical method with detection limits which are, for many trace elements, including the rare earth elements, better than those of most conventional techniques. With increasing availability of ICP-MS instalments in geological laboratories this method has been established as the most prominent technique for the determination of a large number of minor and trace elements in geological samples. [Pg.454]

GC/MS has been employed by Demeter et al. (1978) to quantitatively detect low-ppb levels of a- and P-endosulfan in human serum, urine, and liver. This technique could not separate a- and P-isomers, and limited sensitivity confined its use to toxicological analysis following exposures to high levels of endosulfan. More recently, Le Bel and Williams (1986) and Williams et al. (1988) employed GC/MS to confirm qualitatively the presence of a-endosulfan in adipose tissue previously analyzed quantitatively by GC/ECD. These studies indicate that GC/MS is not as sensitive as GC/ECD. Mariani et al. (1995) have used GC in conjunction with negative ion chemical ionization mass spectrometry to determine alpha- and beta-endosulfan in plasma and brain samples with limits of detection reported to be 5 ppb in each matrix. Details of commonly used analytical methods for several types of biological media are presented in Table 6-1. [Pg.249]

Determined by inductively coupled plasma-mass spectrometry of acid digested catalyst samples Calculated from X-ray diffraction peak broadening at (101) foranatase and (110) formtile TiOa Mean particle diameter measured from transmission electron microscopy pictures of gold catalysts... [Pg.414]

Moens L, Verreft P, Boonen S, Vanhaecke F and Dams R (1995) Solid sampling electrothermal vaporization for sample introduction in inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry. Spectrochim Acta 508 463-475. Mooijman KA, In t Veld PH, Hoekstra JA, Heisterkamp SH, Havelaar AH, Notermans SHW, Roberts D, Griepink B, Maier E (1992) Development of Microbiological Reference Materials. European Commission Report EUR 14375 EN, Community Bureau of Reference, Brussels. [Pg.46]

In contrast to thermal ionization methods, where the tracer added must be of the same element as the analyte, tracers of different elemental composition but similar ionization efficiency can be utilized for inductively coupled plasma mass spectrometry (ICPMS) analysis. Hence, for ICPMS work, uranium can be added to thorium or radium samples as a way of correcting for instrumental mass bias (e g., Luo et al. 1997 Stirling et al. 2001 Pietruszka et al. 2002). The only drawback of this approach is that small inter-element (e g., U vs. Th) biases may be present during ionization or detection that need to be considered and evaluated (e.g., Pietruszka et al. 2002). [Pg.27]

Becker JS, Pickhardt C, Dietze H-J (2000) Laser ablation inductively coupled plasma mass spectrometry for the trace, ultratrace and isotope analysis of long-lived radionuclides in solid samples. Inti J Mass Spectrom 202 283-297... [Pg.55]

Gray AL (1985). Solid sample introduction by laser ablation for inductively coupled plasma source mass spectrometry. Analyst 110 551-556... [Pg.56]


See other pages where Mass spectrometry samples plasma is mentioned: [Pg.132]    [Pg.308]    [Pg.464]    [Pg.29]    [Pg.97]    [Pg.353]    [Pg.397]    [Pg.549]    [Pg.395]    [Pg.85]    [Pg.317]    [Pg.323]    [Pg.46]    [Pg.529]    [Pg.530]    [Pg.530]    [Pg.622]    [Pg.625]    [Pg.634]    [Pg.147]    [Pg.71]    [Pg.138]    [Pg.113]    [Pg.4]    [Pg.39]   
See also in sourсe #XX -- [ Pg.359 , Pg.361 ]




SEARCH



Mass plasma

Plasma mass spectrometry

Plasma spectrometry)

Sample mass

Sample mass spectrometry

Sample spectrometry

© 2024 chempedia.info