Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mass spectrometry, chemical ionization

Harrison A G 1992 Chemical Ionization Mass Spectrometry (Boca Raton, FL Chemloal Rubber Company)... [Pg.1358]

Diphenylthiirene 1-oxide and several thiirene 1,1-dioxides show very weak molecular ions by electron impact mass spectrometry, but the molecular ions are much more abundant in chemical ionization mass spectrometry (75JHC21). The major fragmentation pathway is loss of sulfur monoxide or sulfur dioxide to give the alkynic ion. High resolution mass measurements identified minor fragment ions from 2,3-diphenylthiirene 1-oxide at mje 105 and 121 as PhCO" and PhCS, which are probably derived via rearrangement of the thiirene sulfoxide to monothiobenzil (Scheme 2). [Pg.135]

C. Aguilar, I. Feirer, R Bonnll, R. M. Marce and D. Barcelo, Monitoring of pesticides in river water based on samples previously stored in polymeric cartridges followed by on-line solid-phase extraction-liquid cliromatography-diode array detection and confirmation by atmospheric pressure chemical ionization mass spectrometry . Anal. Chim. Acta 386 237-248 (1999). [Pg.374]

S. Lacorte and D. Barcelo, Determination of parts per trillion levels of organophospho-rus pesticides in groundwater by automated on-line liquid- solid extraction followed by liquid chr omatography/atmospheric pressure chemical ionization mass spectrometry using positive and negative ion modes of operation . Anal. Chem. 68 2464- 2470 (1996). [Pg.374]

I. Eeirer, V. Pichon, M. C. Hennion and D. Barcelo, Automated sample preparation with exti action columns by means of anti-isoproturon immunosorbents for the determination of phenylurea herbicides in water followed by liquid chi omatography diode array detection and liquid clrromatogi aphy-atmospheric pressure chemical ionization mass spectrometry , 7. Chromatogr. Ill 91-98 (1997). [Pg.375]

Chemical ionization mass spectrometry has rapidly found extensive application to many substances (Refs 15, 23 28). Of particular importance is identification of complex and... [Pg.41]

Figure 3.2 Piocesses occurring in chemical ionization mass spectrometry using methane as the reagent gas. Figure 3.2 Piocesses occurring in chemical ionization mass spectrometry using methane as the reagent gas.
GC/MS has been employed by Demeter et al. (1978) to quantitatively detect low-ppb levels of a- and P-endosulfan in human serum, urine, and liver. This technique could not separate a- and P-isomers, and limited sensitivity confined its use to toxicological analysis following exposures to high levels of endosulfan. More recently, Le Bel and Williams (1986) and Williams et al. (1988) employed GC/MS to confirm qualitatively the presence of a-endosulfan in adipose tissue previously analyzed quantitatively by GC/ECD. These studies indicate that GC/MS is not as sensitive as GC/ECD. Mariani et al. (1995) have used GC in conjunction with negative ion chemical ionization mass spectrometry to determine alpha- and beta-endosulfan in plasma and brain samples with limits of detection reported to be 5 ppb in each matrix. Details of commonly used analytical methods for several types of biological media are presented in Table 6-1. [Pg.249]

ZEEB D J, NELSON B c, ALBERT K and DALLUGE J J (2000) Separation and identification of twelve catechins in tea using liquid chromatography/atmospheric pressure chemical ionization-mass spectrometry , Chem, 72, 5020-26. [Pg.159]

Van Breemen, R.B. et al.. Liquid chromatography/mass spectrometry of carotenoids using atmospheric pressure chemical ionization, J. Mass Spectrom., 31, 975, 1996. Tian, Q., Duncan C.J.G., and Schwartz S. J., Atmospheric pressure chemical ionization mass spectrometry and in-source fragmentation of lutein esters, J. Mass Spectrom., 38, 990, 2003. [Pg.477]

Kohler M, NV Heeb (2003) Determination of nitrated phenolic compounds in rain by liquid chromatography/ atmospheric pressure chemical ionization mass spectrometry. Anal Chem 75 3115-3121. [Pg.43]

Roussis SG, JW Fedora (1997) Determination of alkenes in hydrocarbon matrices by acetone chemical ionization mass spectrometry. Anal Chem 69 1550-1556. [Pg.643]

HRCIMS High-resolution chemical ionization mass spectrometry... [Pg.212]

Crescenzi et al. developed a multi-residue method for pesticides including propanil in drinking water, river water and groundwater based on SPE and LC/MS detection. The recoveries of the pesticides by this method were >80%. Santos etal. developed an on-line SPE method followed by LC/PAD and LC/MS detection in a simultaneous method for anilides and two degradation products (4-chloro-2-methylphenol and 2,4-dichlorophenol) of acidic herbicides in estuarine water samples. To determine the major degradation product of propanil, 3,4-dichloroaniline, the positive ion mode is needed for atmospheric pressure chemical ionization mass spectrometry (APCI/MS) detection. The LOD of 3,4-dichloroaniline by APCI/MS was 0.1-0.02 ng mL for 50-mL water samples. [Pg.341]

A. G. Harrison, "Chemical Ionization Mass Spectrometry", CRC Press, Boca Raton, FL, 1983. [Pg.1013]

McClure, TD and Liebler, DC, 1995. Electron capture negative chemical ionization mass spectrometry and tandem mass-spectrometry analysis of beta-carotene, alpha-tocopherol and their oxidation products. J Mass Spectrom 30, 1480-1488. [Pg.347]

Desai,M.J., Armstrong, D.W. (2004). Analysis of native amino acid and peptide enantiomers by high-performance liquid chromatography/atmospheric pressure chemical ionization mass spectrometry. J. Mass. Spec. 39, 177-187. [Pg.340]

W.E. Neff, W.C. Byrdwell, Characterization of model triacylglycerol (triolein, trilinolein and trilinolenin) autoxidation products via high performance liquid chromatography coupled with atmospheric pressure chemical ionization mass spectrometry, Journal of Chromatography A, 818, 169 186 (1998). [Pg.29]

E. Ribechini, F. Modugno, M.P. Colombini, Direct exposure (chemical ionization) mass spectrometry for a rapid characterization of raw and archaeological diterpenoid resinous substances, Microchimica Acta, 162, 405 413 (2008). [Pg.34]


See other pages where Mass spectrometry, chemical ionization is mentioned: [Pg.190]    [Pg.147]    [Pg.156]    [Pg.282]    [Pg.135]    [Pg.42]    [Pg.173]    [Pg.184]    [Pg.197]    [Pg.339]    [Pg.52]    [Pg.63]    [Pg.147]    [Pg.525]    [Pg.420]    [Pg.1142]    [Pg.989]    [Pg.989]    [Pg.60]    [Pg.72]    [Pg.33]   
See also in sourсe #XX -- [ Pg.740 ]

See also in sourсe #XX -- [ Pg.589 , Pg.617 ]




SEARCH



Chemical ionization

Chemical mass spectrometry

Chemical spectrometry

Ionized chemical

Mass chemical ionization

Mass spectrometry ionization

Mass spectrometry ionized

© 2024 chempedia.info