Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mass spectrometry information

In many cases, it may not be necessary to directly detect the radiation being given off at this instant, but rather to just determine the isotopic ratio of an element present in a sample. This can be done using techniques borrowed from analytical chemistry, such as mass spectrometry. Information on the isotopic ratio present, along with knowl-... [Pg.157]

In contrast to IR and NMR spectroscopy, the principle of mass spectrometry (MS) is based on decomposition and reactions of organic molecules on theii way from the ion source to the detector. Consequently, structure-MS correlation is basically a matter of relating reactions to the signals in a mass spectrum. The chemical structure information contained in mass spectra is difficult to extract because of the complicated relationships between MS data and chemical structures. The aim of spectra evaluation can be either the identification of a compound or the interpretation of spectral data in order to elucidate the chemical structure [78-80],... [Pg.534]

As we have just seen interpreting the fragmentation patterns m a mass spectrum m terms of a molecule s structural units makes mass spectrometry much more than just a tool for determining molecular weights Nevertheless even the molecular weight can provide more information than you might think... [Pg.573]

Section 13 22 Mass spectrometry exploits the information obtained when a molecule is ionized by electron impact and then dissociates to smaller fragments Pos itive ions are separated and detected according to their mass to charge (m/z) ratio By examining the fragments and by knowing how classes of molecules dissociate on electron impact one can deduce the structure of a compound Mass spectrometry is quite sensitive as little as 10 g of compound is sufficient for analysis... [Pg.577]

Present day techniques for structure determination in carbohydrate chemistry are sub stantially the same as those for any other type of compound The full range of modern instrumental methods including mass spectrometry and infrared and nuclear magnetic resonance spectroscopy is brought to bear on the problem If the unknown substance is crystalline X ray diffraction can provide precise structural information that m the best cases IS equivalent to taking a three dimensional photograph of the molecule... [Pg.1052]

Nd in samples. Unfortunately, mass spectrometry is not a selective technique. A mass spectrum provides information about the abundance of ions with a given mass. It cannot distinguish, however, between different ions with the same mass. Consequently, the choice of TIMS required developing a procedure for separating the tracer from the aerosol particulates. [Pg.8]

A further important use of El mass spectrometry lies in measuring isotope ratios, which can be used in estimating the ages of artifacts, rocks, or fossils. Electron ionization affects the isotopes of any one element equally, so that the true isotope ratio is not distorted by the ionization step. Further information on isotopes can be found in Chapter 46. [Pg.16]

Although there has been some controversy concerning the processes involved in field ionization mass spectrometry, the general principles appear to be understood. Firstly, the ionization process itself produces little excess of vibrational and rotational energy in the ions, and, consequently, fragmentation is limited or nonexistent. This ionization process is one of the mild or soft methods available for producing excellent molecular mass information. The initially formed ions are either simple radical cations or radical anions (M ). [Pg.25]

Aerosols can be produced as a spray of droplets by various means. A good example of a nebulizer is the common household hair spray, which produces fine droplets of a solution of hair lacquer by using a gas to blow the lacquer solution through a fine nozzle so that it emerges as a spray of small droplets. In use, the droplets strike the hair and settle, and the solvent evaporates to leave behind the nonvolatile lacquer. For mass spectrometry, a spray of a solution of analyte can be produced similarly or by a wide variety of other methods, many of which are discussed here. Chapters 8 ( Electrospray Ionization ) and 11 ( Thermospray and Plasmaspray Interfaces ) also contain details of droplet evaporation and formation of ions that are relevant to the discussion in this chapter. Aerosols are also produced by laser ablation for more information on this topic, see Chapters 17 and 18. [Pg.138]

Metastable ions yield valuable information on fragmentation in mass spectrometry, providing insight into molecular structure. In electron ionization, metastable ions appear naturally along with the much more abundant normal ions. Abundances of metastable ions can be enhanced by collisionally induced decomposition. [Pg.229]

The previous discussion has centered on how to obtain as much molecular mass and chemical structure information as possible from a given sample. However, there are many uses of mass spectrometry where precise isotope ratios are needed and total molecular mass information is unimportant. For accurate measurement of isotope ratio, the sample can be vaporized and then directed into a plasma torch. The sample can be a gas or a solution that is vaporized to form an aerosol, or it can be a solid that is vaporized to an aerosol by laser ablation. Whatever method is used to vaporize the sample, it is then swept into the flame of a plasma torch. Operating at temperatures of about 5000 K and containing large numbers of gas ions and electrons, the plasma completely fragments all substances into ionized atoms within a few milliseconds. The ionized atoms are then passed into a mass analyzer for measurement of their atomic mass and abundance of isotopes. Even intractable substances such as glass, ceramics, rock, and bone can be examined directly by this technique. [Pg.284]

Plasma torches and thermal ionization sources break down the substances into atoms and ionized atoms. Both are used for measurement of accurate isotope ratios. In the breakdown process, all structural information is lost, other than an identification of elements present (e.g., as in inductively coupled mass spectrometry, ICP/MS). [Pg.285]

However, interpretation of, or even obtaining, the mass spectrum of a peptide can be difficult, and many techniques have been introduced to overcome such difficulties. These techniques include modifying the side chains in the peptide and protecting the N- and C-terminals by special groups. Despite many advances made by these approaches, it is not always easy to read the sequence from the mass spectrum because some amide bond cleavages are less easy than others and give little information. To overcome this problem, tandem mass spectrometry has been applied to this dry approach to peptide sequencing with considerable success. Further, electrospray ionization has been used to determine the molecular masses of proteins and peptides with unprecedented accuracy. [Pg.333]

Peptides and proteins can be analyzed by mass spectrometry. Molecular mass information can be obtained particularly well by MALDI and ESI. [Pg.417]

Tandem mass spectrometry (MS/MS) produces precise structural or sequence information by selective and specific induced fragmentation on samples up to several thousand Daltons. For samples of greater molecular mass than this, an enzyme digest will usually produce several peptides of molecular mass suitable for sequencing by mass spectrometry. The smaller sequences can be used to deduce the sequence of the whole protein. [Pg.417]

JICST/JOIS. The Japan Information Center for Science and Technology (fICST) Mass Spectral Database is accessible to users in Japan through the JICST Eactual Database System (fOlS-E). The database uses the NIST/EPA/ MSCD data collection supplemented by spectra from the Mass Spectrometry Society of Japan (84). [Pg.122]

Ideally, a mass spectmm contains a molecular ion, corresponding to the molecular mass of the analyte, as well as stmcturaHy significant fragment ions which allow either the direct deterrnination of stmcture or a comparison to Hbraries of spectra of known compounds. Mass spectrometry (ms) is unique in its abiUty to determine direcdy the molecular mass of a sample. Other techniques such as nuclear magnetic resonance (nmr) and infrared spectroscopy give stmctural information from which the molecular mass may be inferred (see Infrared technology and raman spectroscopy Magnetic spin resonance). [Pg.539]

Gas Chromatography (gc). A principal advantage of gas chromatography has been the faciUty with which it can be combined with mass spectrometry for amino acid identification and confirmation of purity. The gc-mass spectrometry combination offers the advantage of obtaining stmctural information rather than the identification by retention time in hplc. [Pg.284]

Spectrometric Analysis. Remarkable developments ia mass spectrometry (ms) and nuclear magnetic resonance methods (nmr), eg, secondary ion mass spectrometry (sims), plasma desorption (pd), thermospray (tsp), two or three dimensional nmr, high resolution nmr of soHds, give useful stmcture analysis information (131). Because nmr analysis of or N-labeled amino acids enables determiaation of amino acids without isolation from organic samples, and without destroyiag the sample, amino acid metaboHsm can be dynamically analy2ed (132). Proteia metaboHsm and biosynthesis of many important metaboUtes have been studied by this method. Preparative methods for labeled compounds have been reviewed (133). [Pg.285]

Multidimensional or hyphenated instmments employ two or more analytical instmmental techniques, either sequentially, or in parallel. Hence, one can have multidimensional separations, eg, hplc/gc, identifications, ms/ms, or separations/identifications, such as gc/ms (see CHROMATOGRAPHY Mass spectrometry). The purpose of interfacing two or more analytical instmments is to increase the analytical information while reducing data acquisition time. For example, in tandem-mass spectrometry (ms/ms) (17,18), the first mass spectrometer appHes soft ionization to separate the mixture of choice into molecular ions the second mass spectrometer obtains the mass spectmm of each ion. [Pg.394]

Among the modem procedures utilized to estabUsh the chemical stmcture of a molecule, nuclear magnetic resonance (nmr) is the most widely used technique. Mass spectrometry is distinguished by its abiUty to determine molecular formulas on minute amounts, but provides no information on stereochemistry. The third most important technique is x-ray diffraction crystallography, used to estabUsh the relative and absolute configuration of any molecule that forms suitable crystals. Other physical techniques, although useful, provide less information on stmctural problems. [Pg.306]


See other pages where Mass spectrometry information is mentioned: [Pg.36]    [Pg.837]    [Pg.1190]    [Pg.765]    [Pg.116]    [Pg.36]    [Pg.837]    [Pg.1190]    [Pg.765]    [Pg.116]    [Pg.535]    [Pg.540]    [Pg.586]    [Pg.4]    [Pg.29]    [Pg.136]    [Pg.160]    [Pg.240]    [Pg.245]    [Pg.253]    [Pg.261]    [Pg.277]    [Pg.314]    [Pg.397]    [Pg.449]    [Pg.475]    [Pg.475]    [Pg.478]    [Pg.198]    [Pg.349]    [Pg.545]    [Pg.84]    [Pg.172]    [Pg.400]   
See also in sourсe #XX -- [ Pg.16 , Pg.21 ]




SEARCH



Extracting Information from Hydrogen Exchange Mass Spectrometry Data

Mass spectrometry information obtainable

Structural information sources mass spectrometry

Tandem mass spectrometry structural information obtained from

© 2024 chempedia.info