Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Limits of use

Maximum Service Temperature. Because the cellular materials, like their parent polymers (204), gradually decrease in modulus as the temperature rises rather than undergoing a sharp change in properties, it is difficult to precisely define the maximum service temperature of cellular polymers. The upper temperature limit of use for most cellular polymers is governed predominantly by the plastic phase. Fabrication of the polymer into a... [Pg.414]

Meridional circulation in two-dimensional stratospheric models has been specified based on observations or general circulation model calculations recendy efforts have been undertaken to calculate circulations from first principles, within the stratospheric models themselves. An important limitation of using models in which circulations are specified is that these caimot be used to study the feedbacks of changing atmospheric composition and temperature on transport, factors which may be important as atmospheric composition is increasingly perturbed. [Pg.386]

In 1958 the Supreme Court ruled that under the 1938 law, the FDA did not have the authority to estabHsh limits of use for colorants and that they were obligated to decertify or deHst a color if any quantity of it caused harm even though lesser amounts were perfectiy safe (19). The FDA s hands were tied (20). A review of the remaining colors was started and soon several more were deHsted, including FD C YeUow Nos. 1—4. It became obvious that the existing law on certifiable colors was unworkable. [Pg.432]

The basic assumptions of fracture mechanics are (1) that the material behaves as a linear elastic isotropic continuum and (2) the crack tip inelastic zone size is small with respect to all other dimensions. Here we will consider the limitations of using the term K = YOpos Ttato describe the mechanical driving force for crack extension of small cracks at values of stress that are high with respect to the elastic limit. [Pg.494]

This requirement was addressed above but note that the marking has to be permanent and therefore has to be durable under the anticipated conditions of use. It would be wise to seek guidance from the customer if you are in any doubt as to where to place the marking or how to apply it. Metal identification plates stamped with the customer s identity, date of supply, contract, and limitations of use are durable and permanent. [Pg.337]

Parts that could not be examined Quantitative values where possible Description of any defects Statement of any limitations of use Repairs required and a limiting period for their execution... [Pg.146]

For alkaline duty, steel can sometimes be used up to approximately pH 11. Zinc, aluminum and similar metals and their alloys have limited use in alkaline conditions because they dissolve, giving complex anions. Iron and steel react in this way above about pH 12. Approximate limits of use for zinc are pH 6-12 and aluminum alloy pH 4-8. Stainless steels, including the lower grades, can be used even in the presence of chloride ions at pH levels of approximately In the absence of halides they can be used up to about pH 13. [Pg.899]

Fig. 3.63 Limits of use of silicon irons for handling hydrochloric acid solutions (former Ministry of Supply data) for Fe-18Si and Fe-14-5Si alloys... Fig. 3.63 Limits of use of silicon irons for handling hydrochloric acid solutions (former Ministry of Supply data) for Fe-18Si and Fe-14-5Si alloys...
Fig. 3.6S Limits of use of silicon iron for handling sulphuric acid solutions... Fig. 3.6S Limits of use of silicon iron for handling sulphuric acid solutions...
Based on the limitations of using human subjects, simple alternative in vitro models were developed to investigate mechanisms involved in the intestinal absorption process of a compound of interest and to screen the relative bioavailability of a compound from various food matrices. However, the data generated from in vitro approaches must be taken with caution because they are obtained under relatively simplified and static conditions compared to dynamic physiological in vivo conditions. Indeed, the overall bioavailability of a compound is the result of several complex steps that are influenced by many factors including factors present in the gastrointestinal lumen and intestinal cells as described later. Nevertheless, these in vitro approaches are useful tools for guiding further smdies in humans. [Pg.152]

The limitation of using such a model is the assumption that the diffusional boundary layer, as defined by the effective diffusivity, is the same for both the solute and the micelle [45], This is a good approximation when the diffusivities of all species are similar. However, if the micelle is much larger than the free solute, then the difference between the diffusional boundary layer of the two species, as defined by Eq. (24), is significant since 8 is directly proportional to the diffusion coefficient. If known, the thickness of the diffusional boundary layer for each species can be included directly in the definition of the effective diffusivity. This approach is similar to the reaction plane model which has been used to describe acid-base reactions. [Pg.143]

Equation (87) and analogous equations for AG , AHm, and for surface tensions apply to molten salt mixtures in which the interaction potential can be classed as conformal. These relations may also be used to test whether the ionic interaction potential in aqueous solutions may be considered as conformal. Thus, as will be shown in one simple example, the limits of usefulness of some interionic interaction potentials may be tested in ranges of concentration of salts in water too high to obtain absolute values for the partition functions. A similar test may be made for associations in salt vapors such as... [Pg.106]

Antioxidants that may be used in foods that are subject to a standard of identity are laid down in the relevant standard (Table 12.9). In the case of food that is not subject to a standard of identity, additives must be used in accordance with the conditions or limits of use specified in regulations.9 For some types of foodstuffs which have standards of identity, the use of antioxidants is not permitted. No antioxidants may be used, for instance, in dairy products, ices, and egg products. [Pg.292]

A variety of cell culture systems for the modelling of the tracheo-bronchial epithelium are available. These include primary cultures and cell lines of human and animal origins, plus airway cells with characteristics of lung disease such as CF. The advantages and limitations of using a simple culture system compared to one that recreates to a greater extent the epithelial structure and function in vitro should be considered according to the pre-clinical application required. However, this choice is complicated by the lack of comparative data, both between the different cell systems and for in vitro-in vivo correlation, upon which to base such decisions. [Pg.249]

Clearly, a balanced program that gives careful consideration to the limitations of using CROs — to run the studies, provide the statistical analyses, monitor the processes, and even, coordinate the studies performed outside the United States — needs to be evaluated against the more traditional approaches to drug development. The CRO in clinical research is discussed in detail in Chapter 21. [Pg.557]

Non-linear concentration/response relationships are as common in pesticide residue analysis as in analytical chemistry in general. Although linear approximations have traditionally been helpful the complexity of physical phenomena is a prime reason that the limits of usefulness of such an approximation are frequently exceeded. In fact, it should be regarded the rule rather than the exception that calibration problems cannot be handled satisfactorily by linear relationships particularly as the dynamic range of analytical methods is fully exploited. This is true of principles as diverse as atomic absorption spectrometry (U. X-ray fluorescence spectrometry ( ), radio-immunoassays (3), electron capture detection (4) and many more. [Pg.167]

Limitations of using alkaline reflux, as saliva, food, dental infections, etc. can interfere with results. [Pg.106]

Sharratt, M. 1988. Assessing risks from data on other exposure routes. Possibilities and limitations of using toxicity data derived from one exposure route in assessing risks from other exposure routes. Regul. Toxicol. Pharmacol. 8 399 07. [Pg.295]

Well-behaved numerical methods of this type will give more accurate results as the number of discrete points used in the sum is made larger. In the limit of using a very large number of points, these numerical methods converge to the exact result for the integral. [Pg.55]

It is useless for a non-toxic agent. There are few adequate studies on the matter with the limitation of using undifferentiated poisoned subjects and hence the value for lavage and its outcome are controversial. There is some evidence to suggest that it is effective and better than ipecac-induced emesis. [Pg.281]

B. The purpose of this question is to clarify the uses and limitations of use of the COX-2 selective inhibitor celecoxib. Celecoxib, by inhibiting COX-2 reversibly, will block the activity of both injury-... [Pg.328]

J. Legros, B. Crousse, D. Bonnet-Delpon, J.P. Begue, M. Maruta, Trifluoromethylcy-clohexane as a new solvent Limits of use, Tetrahedron 58 (2002) 4067-4070. [Pg.614]


See other pages where Limits of use is mentioned: [Pg.32]    [Pg.433]    [Pg.270]    [Pg.931]    [Pg.412]    [Pg.1]    [Pg.202]    [Pg.72]    [Pg.412]    [Pg.235]    [Pg.369]    [Pg.292]    [Pg.146]    [Pg.418]    [Pg.142]    [Pg.53]    [Pg.181]    [Pg.92]    [Pg.17]    [Pg.348]    [Pg.250]    [Pg.325]    [Pg.50]    [Pg.34]    [Pg.261]    [Pg.110]    [Pg.115]   
See also in sourсe #XX -- [ Pg.157 ]




SEARCH



Advantages and limitations of using multifunctional rare earth organic inhibitors for corrosion protection

Limitations and perspectives in the use of Flash Profile

Limitations of Gas Separations Using Polymer Membranes

Limitations of Polymer Using in Gas Sensors

Limitations of Use

Limitations of Use

Limitations to the use of potentiometric devices

Limited use

Monitoring of Membrane Processes Using Fluorescence Techniques Advances and Limitations

Necessary treatment and possible limitations for external re-use of solid residues

Surface Charge Characteristics of Blood Cells Using Mainly Electrophoresis and to a Limited Extent Sedimentation Potential Techniques

Technical advantages and limitations of using HR

The Meaning and Use of Exposure Limits

Useful Properties of Laplace Transform limit functions

Using the Macrofluid Model to Calculate Limits of Performance

© 2024 chempedia.info