Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Laboratory Set-Up

The materials of the single cell test housing consist of  [Pg.63]

Further, it is possible to study the behavior of the cells to different synthetic fuel mixtures including H2, CO, CO2, N2, CH4, H2O mixtures. The fuel can be [Pg.63]

Milewski et al.. Advanced Methods of Solid Oxide Fuel Cell Modeling, Green Energy and Technology, DOI 10.1007/978-0-85729-262-9 4, [Pg.63]

During testing, cells are placed in an inert ceramic housing consisting of alumina, with alumina flanges for gas distribution, platinum meshes for cathode current collection and nickel meshes for anode current collection. Current collectors are of the double grids mesh type and contact both electrodes directly  [Pg.64]

The experiments were performed on an anode supported planar Solid Oxide Fuel Cell which consists of a 525—610 pm thick anode with two layers (both made of MO/8YSZ cermet functional layer 5—10 pm thick support layer 520—600 p thick) a 4—6 pm thick dense electrolyte Yo,i6Zro.g402 (8YSZ) a 2—4 pm thick barrier layer made of yttria doped ceria (YDC) the cathode consists of a 20—30 pm thick layer made of porous lanthanum strontium cobalt ferrite oxide [Pg.64]


Measurements have been made in a static laboratory set-up. A simulation model for generating supplementary data has been developed and verified. A statistical data treatment method has been applied to estimate tracer concentration from detector measurements. Accuracy in parameter estimation in the range of 5-10% has been obtained. [Pg.1057]

Fig 9 3 A simple laboratory set-up for observing the casting process directly. The mould volume measures about 50 X 50 X 6 mm. The walls are cooled by putting the bottom of the block into a dish of liquid nitrogen. The windows are kept free of frost by squirting them with alcohol from a wash bottle every 5 minutes. [Pg.92]

These apparent restrictions in size and length of simulation time of the fully quantum-mechanical methods or molecular-dynamics methods with continuous degrees of freedom in real space are the basic reason why the direct simulation of lattice models of the Ising type or of solid-on-solid type is still the most popular technique to simulate crystal growth processes. Consequently, a substantial part of this article will deal with scientific problems on those time and length scales which are simultaneously accessible by the experimental STM methods on one hand and by Monte Carlo lattice simulations on the other hand. Even these methods, however, are too microscopic to incorporate the boundary conditions from the laboratory set-up into the models in a reahstic way. Therefore one uses phenomenological models of the phase-field or sharp-interface type, and finally even finite-element methods, to treat the diffusion transport and hydrodynamic convections which control a reahstic crystal growth process from the melt on an industrial scale. [Pg.855]

Fig. 10.7. A complete laboratory set-up of biostat, B. Braun fermenter with external feed pumps and product reservoirs. Fig. 10.7. A complete laboratory set-up of biostat, B. Braun fermenter with external feed pumps and product reservoirs.
This is a 25 to 1 differential. Figure 35 shows one of our technicians in our laboratory setting up and performing the test with a capillary dispenser. [Pg.142]

P 28] A glass interdigital micro mixer was connected to PTFE tubes with an inner diameter of 2 mm which was immersed in an ice-water bath of appropriate temperature (laboratory set-up) [48, 108]. Operation was performed for 5-40 s at temperatures ranging from -12 to 50 °C. [Pg.467]

Figure 4.60 Yield of product and side/consecutive products as a function of flow rate, respectively residence time for the laboratory set-up with an interdigital micro mixer [48],... Figure 4.60 Yield of product and side/consecutive products as a function of flow rate, respectively residence time for the laboratory set-up with an interdigital micro mixer [48],...
OS 40] [R 21] [P 29] A much larger dependence of yield on reaction temperature was observed for the caterpillar mixer-scale-up set-up than for the inter digital mixer-laboratory set-up [48]. At temperatares above ambient, significant decreases in yield of the order of several tens percent were determined. [Pg.469]

The field laboratory set up by the field research group is a key element to completing successful worker exposure/re-entry research. The field laboratory may be set up in close proximity to the treated field, but should be located at a reasonable distance from the treated area to avoid cross-contamination of field samples and field controls. [Pg.993]

Note This series of steps is rather difficult, but once a competent chemist has his laboratory set up properly, it is not as hard as it looks. The small scale at which these steps are designed is overcome by the potency of the drug. Some sources say the racemic versions are not as potent as the 1-forms. You can make either, by obtaining the reference that gave me this formula above JACS, 80, 1186(1958). [Pg.94]

The experimental batch reactor is usually operated isothermally and at constant volume because it is easy to interpret the results of such runs. This reactor is a relatively simple device adaptable to small-scale laboratory set-ups, and it needs but little auxiliary equipment or instrumentation. Thus, it is used whenever possible for obtaining homogeneous kinetic data. This chapter deals with the batch reactor. [Pg.38]

At both the Universal Oil research laboratory and the Ipatieff Catalytic Laboratory at Northwestern (an extension of the original laboratory set up by Ipatieff) Dr Ipatieff was active almost to, the time of his death Ref Anon, Chem Engr News 30, 5300 (1952)... [Pg.397]

Electro-osmotic oscillation (first observed by Teorell [1]—[4] in a laboratory set-up devised to mimic nerve excitation) may likely represent a common source of oscillations in various natural or synthetic electrokinetic systems such as solid microporous filters, synthetic ion-exchange membranes or their biological counterparts. The original experimental set-up, which contained all essential elements to look for when the electro-osmotic oscillations are suspected in a natural system, is schematically as follows. [Pg.203]

Hess s law can be used to calculate reaction enthalpies for hypothetical processes that can t be carried out in the laboratory. Set up a Hess s law cycle that will let you calculate A H° for the conversion of methane to ethylene ... [Pg.338]

Hugh Huffman left Cal Tech during the Second World War and was an important scientist at a national laboratory set up to provide technical information to support the war effort. He left a legacy of high precision experimental techniques that yielded high-quality thermodynamic data on a wide variety of substances, including simple biological molecules. [Pg.229]

Such an evolution is dangerous for several reasons. Despite its attractiveness as a practical tool in a given laboratory set-up there are potential dangers to rely on a method such as this for certification. The problems can be summarised as follows ... [Pg.38]

As with chemical weapons ingredients, the chemical equipment needed to make chemical warfare agents is commercially available just about anywhere. Certainly, to set up a full-scale poison gas production line, terrorists would need reactors and agitators, chemical storage tanks, containers, receivers, condensers for temperature control, distillation columns to separate chemical compounds, valves and pumps to move chemicals between reactors and other containers. Additionally, ideally the equipment would be corrosion-resistant. For a full-scale mustard gas production plant the price tag would be between 2.5 and 5 million. Approximately 10 million would be required to set up a plant to manufacture tabun, sarin or soman.47 Terrorists, however, can be assumed to forego the scale and the safety precautions that most governments would consider essential for a weapons programme. In fact, standard process equipment or a laboratory set-up of beakers and... [Pg.144]

SF If one had a laboratory set up for radiation genetics and one decided to study chemical mutagens, what kind of changes would have to take place ... [Pg.161]

Picture 1. OPCW mobile laboratory set up during an IAU exercise... [Pg.38]

Waysbort, D., E. Manisterski, H. Leader, B. Manisterski, and Y. Ashani. 2004. Laboratory set-up for long-term monitoring of the volatilization of hazardous materials Preliminary tests of O-ethyl S-2- (N,N-diisopropylamino)ethyl methylphosphonothiolate on asphalt. Environmental Science and Technology 38(7) 2217-2223. [Pg.75]

However, that is not to say the art was no longer practiced Charles II had an alchemical laboratory set up beneath the royal bedchamber, and Robert Boyle, although publicly repudiating alchemy in his book The Sceptical Chymist, still practised the art in secret. And in 1672, there was elected to the Royal Society a man who has come to be regarded as the greatest scientist of all time, yet who was also a practising alchemist Sir Isaac Newton. [Pg.76]

Barchusen was one of the last chemists to exhibit an interest in alchemy, and worked from a laboratory set up in the city walls of Utrecht. His book Elementa Chemiae is full of alchemical illustrations. [Pg.140]

Figure 4.5 Schematic diagram of typical SCCO2 laboratory set-up for reactions. Inset left, cylinder, circulating chilling unit and syringe pump. Inset right, typical pressure vessel. Figure 4.5 Schematic diagram of typical SCCO2 laboratory set-up for reactions. Inset left, cylinder, circulating chilling unit and syringe pump. Inset right, typical pressure vessel.
Batch precipitate flotation with dispersed [10, 11] and dissolved [12 ]air has been carried out on a conventional laboratory set-up microflotation, adopting the procedures described earlier. The air flow rate in the flotation with dispersed air was 3 dm /h... [Pg.312]

Five different mixtures of primary microbio logically treated oil refinery (R) and municipal (M) wastewaters in the volume ratios R/M = 85/15, 70/30, 50/50, 30/70, and 15/85 were subjected to the treatment. Bilogical treatment was carried out on a laboratory set-up by the activated sludge procedure. Four different flow rates in the range of 5.7-45.7 (dm /day) were employed for all water mixtures. [Pg.557]

The FDA considers LDTs medical devices subject to FDA regulatory oversight, but witli very few exceptions has not executed this authority the high complexity laboratories that develop LDTs are regulated by the Center for Medicare and Medicaid Services under the provisions of the Chnicai Laboratory Improvement Act [CLIA] of 1988). With the ASR category, the FDA shifted its focus from the laboratory to the manufacturers of reagents, and proposed controls and restrictions to ensure their quality and consistency, and to clarify that a laboratory setting up these tests is responsible for the tests performance. [Pg.1556]

In order to test class identification based on multi-color native fluorescence we have measured LIF spectra for representative bio-agent simulants in solution for various classes of bio-molecules (i.e., toxins, viruses and bacteria) with a conventional laboratory set-up. For a proof-of-concept, the library of spectra was subjected to a mathematical procedure to extract and evaluate distinguishing features of the analytes. In a second step, the extracted distinguishing features were used to teach a multidimensional classifying... [Pg.43]

I resisted growing the psilocybians for over twenty years. Sterile procedure is essential, and having worked as a lab assistant, I know how easy it is for contamination to occur even after taking the most stringent precautions. I believed it had to be more trouble than it was worth unless you had access to an expensive laboratory set-up - surely nobody could have much success doing this in their kitchen. Then one day a friend gave me three sealed petri dishes containing Psilocybe cubensis... [Pg.199]

Size-exclusion chromatography is an important separation method. It provides an easy way of solving many types of problem and as such should form an integral part of any HPLC laboratory set-up. There are four main areas of application ... [Pg.244]

This laboratory set-up permitted accurate variations of both the angle of incidence (0) and the scattering angle ((()). The test panels were mounted magnetically and could be shifted two-dimen-sionally to allow scanning of their entire surface. [Pg.95]

Based on the experience gained with the laboratory set-up, a prototype instrument was then built, the Shell "Blushmeter" (Fig. U). A 2 mW He-Ne laser is used and the optical arrangement is essentially the same as described above, with <() and 0 fixed at 70 and 60°, respectively. Flat test panels are clamped magnetically onto a horizontal sample table which can be displaced (at 0.2 cm/s) in the X and Y directions by means of two electric stepping motors. Digital read-out of the actual position permits accurate and reproducible scanning of the entire panel surface. [Pg.95]


See other pages where Laboratory Set-Up is mentioned: [Pg.143]    [Pg.467]    [Pg.518]    [Pg.72]    [Pg.125]    [Pg.136]    [Pg.59]    [Pg.701]    [Pg.159]    [Pg.17]    [Pg.140]    [Pg.212]    [Pg.12]    [Pg.23]    [Pg.79]    [Pg.253]    [Pg.397]    [Pg.139]    [Pg.21]    [Pg.93]   


SEARCH



Laboratory setting

© 2024 chempedia.info