Generalized spectrometry

Analysis of such cuts by spectrometry requires a preliminary separation by chemical constituents. The separation is generally done by liquid phase chromatography described in article 3.3.5. [Pg.50]

This is an analysis frequently conducted on oil lubricants. Generally, the additive is known and its concentration can be followed by direct comparison of the oil with additive and the base stock. For example, concentrations of a few ppm of dithiophosphates or phenols are obtained with an interferometer. However, additive oils today contain a large number of products their identification or their analysis by IR spectrometry most often requires preliminary separation, either by dialysis or by liquid phase chromatography. [Pg.62]

A big step forward came with the discovery that bombardment of a liquid target surface by abeam of fast atoms caused continuous desorption of ions that were characteristic of the liquid. Where this liquid consisted of a sample substance dissolved in a solvent of low volatility (a matrix), both positive and negative molecular or quasi-molecular ions characteristic of the sample were produced. The process quickly became known by the acronym FAB (fast-atom bombardment) and for its then-fabulous results on substances that had hitherto proved intractable. Later, it was found that a primary incident beam of fast ions could be used instead, and a more generally descriptive term, LSIMS (liquid secondary ion mass spectrometry) has come into use. However, note that purists still regard and refer to both FAB and LSIMS as simply facets of the original SIMS. In practice, any of the acronyms can be used, but FAB and LSIMS are more descriptive when referring to the primary atom or ion beam. [Pg.17]

Although there has been some controversy concerning the processes involved in field ionization mass spectrometry, the general principles appear to be understood. Firstly, the ionization process itself produces little excess of vibrational and rotational energy in the ions, and, consequently, fragmentation is limited or nonexistent. This ionization process is one of the mild or soft methods available for producing excellent molecular mass information. The initially formed ions are either simple radical cations or radical anions (M ). [Pg.25]

The term nebulizer is used generally as a description for any spraying device, such as the hair spray mentioned above. It is normally applied to any means of forming an aerosol spray in which a volume of liquid is broken into a mist of vapor and small droplets and possibly even solid matter. There is a variety of nebulizer designs for transporting a solution of analyte in droplet form to a plasma torch in ICP/MS and to the inlet/ionization sources used in electrospray and mass spectrometry (ES/MS) and atmospheric-pressure chemical ionization and mass spectrometry (APCI/MS). [Pg.138]

In modem mass spectrometry, ion collectors (detectors) are generally based on the electron multiplier and can be separated into two classes those that detect the arrival of all ions sequentially at a point (a single-point ion collector) and those that detect the arrival of all ions simultaneously (an array or multipoint collector). This chapter compares the uses of single- and multipoint ion collectors. For more detailed discussions of their construction and operation, see Chapter 28, Point Ion Collectors (Detectors), and Chapter 29, Array Collectors (Detectors). In some forms of mass spectrometry, other methods of ion detection can be used, as with ion cyclotron instmments, but these are not considered here. [Pg.211]

Until 1981, mass spectrometry was limited, generally, to the analysis of volatile, relatively low-molecular-mass samples and was difficult to apply to nonvolatile peptides and proteins without first cutting them chemically into smaller volatile segments. During the past decade, the situation has changed radically with the advent of new ionization techniques and the development of tandem mass spectrometry. Now, the mass spectrometer has a well-deserved place in any laboratory interested in the analysis of peptides and proteins. [Pg.287]

This example can be used in reverse to show the usefulness of looking for such isotopes. Suppose there were an unknown sample that had two molecular ion peaks in the ratio of 3 1 that were two mass units apart then it could reasonably be deduced that it was highly likely the unknown contained chlorine. In this case, the isotope ratio has been used to identify a chlorine-containing compound. This use of mass spectrometry is widespread in general analysis of materials, and it... [Pg.339]

Desorption ionization (DI). General term to encompass the various procedures (e.g., secondary ion mass spectrometry, fast-atom bombardment, californium fission fragment desorption, thermal desorption) in which ions are generated directly from a solid or liquid sample by energy input. Experimental conditions must be clearly stated. [Pg.438]

Confirmation of the identities of nitrosamines generally is accompHshed by gas chromatography—mass spectrometry (gc/ms) (46,87). High resolution gc/ms, as well as gc/ms in various single-ion modes, can be used as specific detectors, especially when screening for particular nitrosamines (87) (see Analytical LffiTHODS Trace and residue analysis). [Pg.109]

Atomic Absorption/Emission Spectrometry. Atomic absorption or emission spectrometric methods are commonly used for inorganic elements in a variety of matrices. The general principles and appHcations have been reviewed (43). Flame-emission spectrometry allows detection at low levels (10 g). It has been claimed that flame methods give better reproducibiHty than electrical excitation methods, owing to better control of several variables involved in flame excitation. Detection limits for selected elements by flame-emission spectrometry given in Table 4. Inductively coupled plasma emission spectrometry may also be employed. [Pg.243]

Environment. Detection of environmental degradation products of nerve agents directly from the surface of plant leaves using static secondary ion mass spectrometry (sims) has been demonstrated (97). Pinacolylmethylphosphonic acid (PMPA), isopropylmethylphosphonic acid (IMPA), and ethylmethylphosphonic acid (EMPA) were spiked from aqueous samples onto philodendron leaves prior to analysis by static sims. The minimum detection limits on philodendron leaves were estimated to be between 40 and 0.4 ng/mm for PMPA and IMPA and between 40 and 4 ng/mm for EMPA. Sims analyses of IMPA adsorbed on 10 different crop leaves were also performed in order to investigate general apphcabiflty of static sims for... [Pg.247]

Searching. A tmncation feature ( ) that allows word variation, eg, "mass spectrometry or mass spectroscopy" is used. Tide searching is accomphshed by using the added modifier "/ti" to bring up only tides. Commands to retrieve information generally use a protocol such as type-set number/format choice/number of records. [Pg.458]

Oils are mixtures of mixed esters with different fatty acids distributed among the ester molecules. Generally, identification of specific esters is not attempted instead the oils are characterized by analysis of the fatty acid composition (8,9). The principal methods have been gas—Hquid and high performance Hquid chromatographic separation of the methyl esters of the fatty acids obtained by transesterification of the oils. Mass spectrometry and nmr are used to identify the individual esters. It has been reported that the free fatty acids obtained by hydrolysis can be separated with equal accuracy by high performance Hquid chromatography (10). A review of the identification and deterrnination of the various mixed triglycerides is available (11). [Pg.260]

The oceurrence of a large number of pyrazines as flavouring or aroma eonstituents and as pheromones in extremely low coneentrations has led to mass spectrometry being the method of ehoiee for determining the gross struetural details of a pyrazine nueleus. The method appears to be generally applieable and relatively specifie and sensitive. [Pg.162]

The use of UV spectroscopy as an identification method is continuously decreasing in relative importance compared to the use of NMR or mass spectrometry. However, due to the general validity of Beer s law, it continues to be an appropriate method for quantitative studies such as the measurement of ionization constants (Section 4.04.2.1.3(iv) and (v)) and the determination of tautomeric equilibrium constants (Section 4.04.4.1.5). [Pg.197]

GENERALIZED DESCRIPTION OF POWDER AND POWDER SLURRY-LIKE MATERIALS IN X-RAY FLUORESCENCE SPECTROMETRY... [Pg.113]

Although XRF is generally the X-ray spectrometry method of choice for analysis of major and trace elements in bulk specimens, useful PIXE measurements can be made. A detailed review of the main considerations for thick-target PEXE provides guidance for trace analysis with known and unknown matrices and bulk analysis when the constituents are unknown. Campbell and Cookson also discuss the increased importance of secondary fluorescence and geometrical accuracy for bulk measurements. [Pg.363]


See other pages where Generalized spectrometry is mentioned: [Pg.73]    [Pg.76]    [Pg.77]    [Pg.73]    [Pg.76]    [Pg.77]    [Pg.11]    [Pg.873]    [Pg.1823]    [Pg.2390]    [Pg.2725]    [Pg.134]    [Pg.195]    [Pg.245]    [Pg.343]    [Pg.212]    [Pg.191]    [Pg.198]    [Pg.199]    [Pg.201]    [Pg.172]    [Pg.171]    [Pg.400]    [Pg.313]    [Pg.243]    [Pg.214]    [Pg.205]    [Pg.358]    [Pg.418]    [Pg.489]    [Pg.490]    [Pg.533]    [Pg.622]    [Pg.624]    [Pg.634]   
See also in sourсe #XX -- [ Pg.97 ]




SEARCH



General Properties of Chromatography-Mass Spectrometry Coupling

Isotope ratio mass spectrometry general

Mass spectrometry (General)

Mass spectrometry general applications

Mass spectrometry general features

Quadrupole mass, generally spectrometry

Small-molecule , generally mass spectrometry

Tandem mass spectrometry general principle

Tandem mass spectrometry techniques, generally

The general status of mass spectrometry in peptide analysis