For either the in-line or hybrid analyzers, the ions injected into the TOF section must all begin their flight down the TOF tube at the same instant if arrival times of ions at a detector are to be used to measure m/z values (see Chapter 26, TOF Ion Optics ). For the hybrid TOF instruments, the ion detector is usually a microchannel plate ion counter (see Chapter 30, Comparison of Multipoint Collectors (Detectors) of Ions Arrays and MicroChannel Plates ). [Pg.153]

An AutoSpec-TOF mass spectrometer has a magnetic sector and an electron multiplier ion detector for carrying out one type of mass spectrometry plus a TOF analyzer with a microchannel plate multipoint ion collector for another type of mass spectrometry. Either analyzer can be used separately, or the two can be run in tandem (Figure 20.4). [Pg.154]

Comparison of Multipoint Collectors (Detectors) of Ions Arrays and MicroChannel Plates... [Pg.211]

In modem mass spectrometry, ion collectors (detectors) are generally based on the electron multiplier and can be separated into two classes those that detect the arrival of all ions sequentially at a point (a single-point ion collector) and those that detect the arrival of all ions simultaneously (an array or multipoint collector). This chapter compares the uses of single- and multipoint ion collectors. For more detailed discussions of their construction and operation, see Chapter 28, Point Ion Collectors (Detectors), and Chapter 29, Array Collectors (Detectors). In some forms of mass spectrometry, other methods of ion detection can be used, as with ion cyclotron instmments, but these are not considered here. [Pg.211]

A multipoint ion collector (also called the detector) consists of a large number of miniature electron multiplier elements assembled, or constructed, side by side over a plane. A multipoint collector can be an array, which detects a dispersed beam of ions simultaneously over a range of m/z values and is frequently used with a sector-type mass spectrometer. Alternatively, a microchannel plate collector detects all ions of one m/z value. When combined with a TOP analyzer, the microchannel plate affords an almost instantaneous mass spectrum. Because of their construction and operation, microchannel plate detectors are cheaper to fit and maintain. Multipoint detectors are particularly useful for situations in which ionization occurs within a very short space of time, as with some ionization sources, or in which only trace quantities of any substance are available. For such fleeting availability of ions, only multipoint collectors can measure a whole spectrum or part of a spectrum satisfactorily in the short time available. [Pg.217]

Recording of a dispersed ion beam can take place either at a point (see Chapter 28, Point Ion Collectors ) or across a plane, as in the multipoint collectors discussed here. [Pg.409]

A multipoint collector is an assembly (array) of single-point collectors (elements), packed closely together in a plane. [Pg.409]

Ions arrive at one end of each element of a multipoint collector and trigger a cascade of electrons, which moves toward the opposite end and is detected electronically. The resulting electric current corresponds to the ion current. [Pg.409]

In a mass spectrometer, ions can arrive at a multipoint collector as a spatially dispersed beam. This means that all ions of different m/z values arrive simultaneously but separated in space according to each m/z value. Each element of the array, depending on its position in space, detects one particular m/z value (see Chapter 29, Array Collectors ). [Pg.410]

Alternatively, the ions in a mass spectrometer can also arrive at a multipoint collector as a temporally dispersed beam. Therefore, at any point in time, all ions of the same m/z value arrive simultaneously, and different m/z values arrive at other times. Ail elements of this collector detect the arrival of ions of one m/z value at any one instant of time. This type of detector, which is also an array, is called a microchannel plate collector of ions. [Pg.410]

To differentiate tteir functions and modes of operation, the array collector of spatially dispersed m/z values is still called an array collector for historical reasons, but the other multipoint detector of a temporally dispersed range of m/z values is called a microchannel plate (typically used in time-of-flight instruments). [Pg.410]

After the analyzer of a mass spectrometer has dispersed a beam of ions in space or in time according to their various m/z values, they can be collected by a planar assembly of small electron multipliers. There are two types of multipoint planar collectors an array is used in the case of spatial separation, and a microchannel plate is used in the case of temporal separation. With both multipoint assemblies, all ions over a specified mass range are detected at the same time, or apparently at the same time, giving these assemblies distinct advantages over the single-point collector in the analysis of very small quantities of a substance or where ions are produced intermittently during short time intervals. [Pg.410]