King, 1971 Naphtali and Sandholm, 1971 Newman, 1963 and Tomich, 1970). Moreover the choice of appropriate computation procedures for distillation, absorption, and extraction is highly dependent on the system being separated, the conditions of separation, and the specifications to be satisfied (Friday and Smith, 1964 Seppala and Luus, 1972). The thermodynamic methods presented in Chapters 3, 4, and 5, particularly when combined to... [Pg.110]

Another variable that needs to be set for distillation is refiux ratio. For a stand-alone distillation column, there is a capital-energy tradeoff, as illustrated in Fig. 3.7. As the refiux ratio is increased from its minimum, the capital cost decreases initially as the number of plates reduces from infinity, but the utility costs increase as more reboiling and condensation are required (see Fig. 3.7). If the capital... [Pg.77]

All these arguments can be summarized by a simple statement The appropriate placement for distillation is not across the pinch. ... [Pg.343]

The thermodynamic profile of an evaporator also can be manipulated. The approach is similar to that used for distillation columns, but the degrees of freedom are obviously different. [Pg.356]

For distilled fractions greater than 50% in volume, the two curves are considered identical. For distilled fractions at 30, 10 and 0 volume %, the temperatures are obtained using the following relations (s I J j... [Pg.165]

The material to be steam-distilled (mixed with some water if a solid compound, but not otherwise) is placed in C, and a vigorous current of steam blown in from D. The mixture in C is thus rapidly heated, and the vapour of the organic compound mixed with steam passes over and is condensed in E. For distillations on a small scale it is not necessary to heat C if, however, the flask C contains a large volume of material or material which requires prolonged distillation, it should be heated by a Bunsen burner, otherwise the steady condensation of steam in C will produce too great a volume of liquid. [Pg.33]

It is often advisable to lubricate ground-glass joint surfaces with an extremely thin film of vaseline. This applies particularly to joints employed in assemblies for distillation under reduced pressure. For distillations under greatly reduced pressures or at very high temperatures it is essential to employ a special lubricant, e.g., silicone grease. [Pg.42]

Fig. 23(E) shows a distillation assembly particularly useful for distilling ether from an ethereal extract. When all the ether has distilled over, the drop-ping-funnel may be replaced by a thermometer for distillation of the residual liquid the adaptor A and the receiver B can then be replaced by the simple adaptor shown in Fig. 23(D) and a flask or bottle of suitable size. Fig. 23(E) shows a distillation assembly particularly useful for distilling ether from an ethereal extract. When all the ether has distilled over, the drop-ping-funnel may be replaced by a thermometer for distillation of the residual liquid the adaptor A and the receiver B can then be replaced by the simple adaptor shown in Fig. 23(D) and a flask or bottle of suitable size.
A skilled worker can use a micro-Bunsen burner for most types of heating. Nevertheless, as there is a tendency for a liquid to shoot out of a small test tube when heated, it is preferable to place the tube in a hot water-bath or in a metal heating block. A small glycerol bath is suitable for distillations and heating under reflux, the glycerol being subsequently easily removed from flasks, etc., by washing with water. [Pg.60]

Add 23 g. of powdered (or flake ) sodium hydroxide to a solution of 15 ml. (18 g.) of nitrobenzene in 120 ml. of methanol contained in a 250 ml. short-necked bolt-head flask. Fix a reflux water-condenser to the flask and boil the solution on a water-bath for 3 hours, shaking the product vigorously at intervals to ensure thorough mixing. Then fit a bent delivery-tube to the flask, and reverse the condenser for distillation, as in Fig. 59, p. 100, or Fig. 23(D), p. 45). Place the flask in the boiling water-bath (since methanol will not readily distil when heated on a water-bath) and distil off as much methanol as possible. Then pour the residual product with stirring into about 250 ml. of cold water wash out the flask with water, and then acidify the mixture with hydrochloric acid. The crude azoxybenzene separates as a heavy oil, which when thoroughly stirred soon solidifies, particularly if the mixture is cooled in ice-water. [Pg.212]

Place 20 g. of dry powdered benzoic acid in C, add 15 ml. (25 g., i.e., a 30% excess) of thionyl chloride and some fragments of porcelain, and then clamp the apparatus on a boiling water-bath as shown so that no liquid can collect in the side-arm of C. Heat for one hour (with occasional gentle shaking), by which time the evolution of gas will be complete. Cool the flask C, detach the condenser and fit it to the side-arm for distillation, using a 360° thermometer for the neck of C. To the lower end of the condenser fit a small conical flask G (Fig. 67(B)) by a cork carrying also a calcium chloride tube. [Pg.241]

Now disconnect the condenser and re-attach it to the flask by a knee-tube for distillation (Fig. 59, p. 100), unless the apparatus in Fig. 38 has been used. Distil off about 5 ml. of the liquid. [Pg.356]

For distillations conducted at atmospheric pressure, the barometric pressures are rarely exactly 760 mm. and deviations may be as high as 20 mm. To correct the observed boiling point to normal pressiu e (760 mm.), the following approximate expression may be used ... [Pg.2]

Rubber stoppers are frequently employed in the laboratory in vacuum distiUation assemblies (compare Section 11,19) for distillations under atmospheric pressure bark corks are generally used. Many organic liquids and vapours dissolve new rubber stoppers slightly and cause them to swell. In practice, it is found that rubber stoppers which have been previously used on one or two occasions are not appreciably attacked by most organic solvents, owing presumably... [Pg.56]

Fig. 11, 13, 4 shows an assembly which is useful inter alia for distilling off solvents from solutions. The solution is placed in the separatory... [Pg.87]

The theory of, and the apparatus for, distillation with superheated steam are described in Section 1,7. [Pg.149]

Attention is directed to the fact that ether is highly inflammable and also extremely volatile (b.p. 35°), and great care should be taken that there is no naked flame in the vicinity of the liquid (see Section 11,14). Under no circumstances should ether be distilled over a bare flame, but always from a steam bath or an electrically-heated water bath (Fig.//, 5,1), and with a highly efficient double surface condenser. In the author s laboratory a special lead-covered bench is set aside for distillations with ether and other inflammable solvents. The author s ether still consists of an electrically-heated water bath (Fig. 11, 5, 1), fitted with the usual concentric copper rings two 10-inch double surface condensers (Davies type) are suitably supported on stands with heavy iron bases, and a bent adaptor is fitted to the second condenser furthermost from the water bath. The flask containing the ethereal solution is supported on the water bath, a short fractionating column or a simple bent still head is fitted into the neck of the flask, and the stUl head is connected to the condensers by a cork the recovered ether is collected in a vessel of appropriate size. [Pg.165]

Distillation heads (or still heads). Fig. II, 56, 5 is a bend ( knee tube ), which is frequently employed for distillation. Convenient sizes are bottom cone 19, 24, 29 or 34 side cone 19 or 24. [Pg.213]

The swan neck adapter of Fig. II, 56, 12 is useful for distillations as it permits the use of a capillary tube (held in position by a short length of heavy-walled rubber tubing) not sealed to a ground joint. It may also be used for inser tion of a thermometer or a gas-inlet tube in the narrow neck and a reflux condenser into the ground joint this device virtually converts a three-necked into a four-necked flask. Common sizes are cone fil9, 24, 29, or 34 socket 19, 24 or 29. [Pg.215]

Lubrication of all ground glass surfaces is essential for distillations under reduced pressure. Suitable lubricants are Apiezon grease L, M or N and Silicone stopcock grease also Alkathene (a polyethylene plastic), which is especially suitable for high temperatures. [Pg.225]

A set-up for distillation under reduced pressure is shown in Fig. 11,60,3 it is generally more convenient to use a Kon receiver or a Perkin triangle (Fig. 11, 56, 31). The vessel at the side, connected to the assembly by rubber pressure tubing, may be immersed in a Dry Ice-acetone bath and serves as a trap for volatile materials. [Pg.227]

Fit up the apparatus shown in Fig. Ill, 31, 1 the capacity of the Claisen flask should be 100 ml. Place 40 g. (24-6 ml.) of redistilled thionyl chloride in the flask and 60 g. (62 ml.) of dry n-butyl alcohol (b.p. 116-117°) in the dropping funnel. Cool the flask in ice and add the n-butyl alcohol, with frequent shaking, over 1 hour (1). Reflux the mixture gently for 1 hour to complete the reaction and to remove the residual hydrogen chloride. Arrange the apparatus for distillation, and distil under normal pressure until the temperature rises to 120° then distil under diminished pressure (Fig. 11, 20, 1) and collect the di-n-butyl sulphite at 116-118°/20 mm. The yield is 66 g. [Pg.303]

Pinacolone. In a 500 ml. round-bottomed flask carrying a dropping funnel and a connection to a condenser set for distillation, place 50 g. of pinacol hydrate and 130 ml. of QN sulphuric acid. Distil the mixture until the upper layer of the distillate no longer increases in volume (15-20 minutes). Separate the pinacolone layer from the water and return the latter to the reaction flask. Then add 12 ml. of concentrated sulphuric acid to the water, followed by a second 50 g. portion of pinacol hydrate. Repeat the distillation. Repeat the process twice more until 200 g. of pinacol hydrate have been used. [Pg.351]

IsoValeric acid. Prepare dilute sulphuric acid by adding 140 ml. of concentrated sulphuric acid cautiously and with stirring to 85 ml. of water cool and add 80 g. (99 ml.) of redistilled woamyl alcohol. Place a solution of 200 g. of crystallised sodium dicliromate in 400 ml. of water in a 1-litre (or 1-5 litre) round-bottomed flask and attach an efficient reflux condenser. Add the sulphuric acid solution of the isoamyl alcohol in amaU portions through the top of the condenser shake the apparatus vigorously after each addition. No heating is required as the heat of the reaction will suffice to keep the mixture hot. It is important to shake the flask well immediately after each addition and not to add a further portion of alcohol until the previous one has reacted if the reaction should become violent, immerse the flask momentarily in ice water. The addition occupies 2-2-5 hours. When all the isoamyl alcohol has been introduced, reflux the mixture gently for 30 minutes, and then allow to cool. Arrange the flask for distillation (compare Fig. II, 13, 3, but with the thermometer omitted) and collect about 350 ml. of distillate. The latter consists of a mixture of water, isovaleric acid and isoamyl isovalerate. Add 30 g. of potassium not sodium) hydroxide pellets to the distillate and shake until dissolved. Transfer to a separatory funnel and remove the upper layer of ester (16 g.). Treat the aqueous layer contained in a beaker with 30 ml. of dilute sulphuric acid (1 1 by volume) and extract the liberated isovaleric acid with two... [Pg.355]

To obtain a maximum yield of the acid it is necessary to hydrolyse the by-product, iaoamyl iaovalerate this is most economically effected with methyl alcoholic sodium hydroxide. Place a mixture of 20 g. of sodium hydroxide pellets, 25 ml. of water and 225 ml. of methyl alcohol in a 500 ml. round-bottomed flask fitted with a reflux (double surface) condenser, warm until the sodium hydroxide dissolves, add the ester layer and reflux the mixture for a period of 15 minutes. Rearrange the flask for distillation (Fig. II, 13, 3) and distil off the methyl alcohol until the residue becomes pasty. Then add about 200 ml. of water and continue the distfllation until the temperature reaches 98-100°. Pour the residue in the flask, consisting of an aqueous solution of sodium iaovalerate, into a 600 ml. beaker and add sufficient water to dissolve any solid which separates. Add slowly, with stirring, a solution of 15 ml. of concentrated sulphuric acid in 50 ml. of water, and extract the hberated acid with 25 ml. of carbon tetrachloride. Combine this extract with extract (A), dry with a httle anhydrous magnesium or calcium sulphate, and distil off the carbon tetrachloride (Fig. II, 13, 4 150 ml. distiUing or Claisen flask), and then distil the residue. Collect the wovaleric acid 172-176°. The yield is 56 g. [Pg.356]


See other pages where For distillation is mentioned: [Pg.111]    [Pg.348]    [Pg.349]    [Pg.484]    [Pg.89]    [Pg.90]    [Pg.116]    [Pg.118]    [Pg.223]    [Pg.529]    [Pg.16]    [Pg.73]    [Pg.86]    [Pg.88]    [Pg.97]    [Pg.103]    [Pg.273]    [Pg.274]    [Pg.301]    [Pg.314]    [Pg.321]    [Pg.323]    [Pg.351]    [Pg.368]    [Pg.375]   
See also in sourсe #XX -- [ Pg.233 ]




SEARCH



Adapter for steam distillation

Apparatus for continuous column distillation

Apparatus for distillation and refluxing

Apparatus for distillation and refluxing typical assemblies)

Apparatus for distillation of solids

Apparatus for fractional distillation

Apparatus for partial condensation during distillation

Apparatus for steam distillation

Apparatus, adapter for steam distillations

Apparatus, adapter for steam distillations Claisen flask modified with column

Apparatus, adapter for steam distillations bain-marie ware

Apparatus, adapter for steam distillations continuous extractor

Apparatus, adapter for steam distillations distillation

Apparatus, adapter for steam distillations enameled steel pots

Azeotropic Distillation Method for Moisture

Azeotropic Distillation Method for Moisture Determination

Baths for distillation

Boiling point distillation for

Bubble point calculation for a batch distillation column

CONTROL OF REACTIVE DISTILLATIONS FOR ACETIC ACID ESTERIFICATION

Calculated azeotropic distillation results compared for

Calculation of Distillation at Minimum Reflux for Ideal Mixtures

Capillary, for distillation

Capillary, for distillation melting point tubes

Cascades for multicomponent mixture separation via distillation

Choice of Sequence for Simple Nonintegrated Distillation Columns

Column for Batch Distillation

Control Scheme for a Distillation Column

Diagrams of Extractive Reversible Distillation for Three-Component Mixtures

Distillate scheme for

Distillation equipment for

Distillation procedure for

Distillation sequencing, heuristics for

Distillation system for the separation

Distillation under diminished pressure manometers for

Distillation under diminished pressure manostats for

Distillation under diminished pressure preparation of capillaries for

Distillation, assemblies of apparatus for

Electric heating mantles (for use in fractional distillation, etc

Energy optimization for distillation system

Energy requirements for distillation

Equipment for separation by fractional distillation

Flasks for distilling solids under reduced

For distillation of solids

For fractional distillation

Fractional distillation efficient units for

Fractional distillation improved apparatus for

Fractional distillation simple apparatus for

Fractional distillation still-heads for

Fractional distillation under diminished flasks for

Fractional distillation under diminished receivers for

Guides for Emergency Response Chemical Agent or Weapon Distilled Mustard (H, HD)

Hand Calculations for Distillation Towers

How to assemble the apparatus for a simple distillation

Hybrid Model Development for Pilot Batch Distillation Column

Importance of Reaction Kinetics for Catalytic Distillation Processes

Improve the 5 Distillation Point for an Individual Cut

Instructions for the calculation of distillation conditions

Internals for Reactive Distillation

Methods for determining the plate number in batch distillation arithmetically

Molecular distillation still for

Multicomponent distillation short-cut methods for stage and reflux requirements

NET Equations for Distillation Columns

PACKED COLUMNS FOR DISTILLATION

Plantwide Control Issues for Distillation Columns

Process synthesis for distillation

Sequencing for Azeotropic Distillation

Skill 4.1e-Describe various methods for separation of solutions (e.g., chromatography, distillation)

Test Method for Distillation Range of Volatile Organic Liquids

Test Method for Distillation of Crude Petroleum (15-Theoretical Plate Column)

Test Method for Distillation of Industrial Aromatic Hydrocarbons and Related Materials

Test Method for Water in Crude Oil by Distillation

The Best Distillation Complex for Petroleum Refining

Typical assemblies of apparatus for distillation and refluxing

Unstructured Catalytic Packing for Reactive Distillation Processes

Use of Continuous Columns for Batch Distillation