Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fluorescent preparation

Fig. 1. Examples of fluorescence preparations of Drosophila whole mounts using the protocols is described in this chapter. All confocal images were obtained with a LeicaTCS4D confocal microscope, (a) Confocal optical section of a D. melanogaster embryo whole mount at blastoderm stage double stained with phalloidin—rhodamine (red) and DAPI (blue) to allow simultaneous visualization of nuclei and cortical actin around cell membranes. Anterior is to the left. Fig. 1. Examples of fluorescence preparations of Drosophila whole mounts using the protocols is described in this chapter. All confocal images were obtained with a LeicaTCS4D confocal microscope, (a) Confocal optical section of a D. melanogaster embryo whole mount at blastoderm stage double stained with phalloidin—rhodamine (red) and DAPI (blue) to allow simultaneous visualization of nuclei and cortical actin around cell membranes. Anterior is to the left.
The principle of all contrast enhancement systems is to turn otherwise invisible variations in material (density, polarizing ability, and so forth) into differences in perceived light intensity. For embryological specimens, some kind of contrast enhancement is usually extremely useful. For example, with fluorescent preparations, standard counterstains may either quench fluorescence or be autofluorescent themselves. On occasion, however, a particular contrast enhancement may reduce the information within an image for example, Nomarski optics may make small labeled objects (such as cell nuclei) less easy to see. It is always worth viewing a specimen both with and without contrast enhancement before photographing. The use of three common image enhancement systems is described next. [Pg.756]

The choice between X-ray fluorescence and the two other methods will be guided by the concentration levels and by the duration of the analytical procedure X-ray fluorescence is usually less sensitive than atomic absorption, but, at least for petroleum products, it requires less preparation after obtaining the calibration curve. Table 2.4 shows the detectable limits and accuracies of the three methods given above for the most commonly analyzed metals in petroleum products. For atomic absorption and plasma, the figures are given for analysis in an organic medium without mineralization. [Pg.38]

Figure Al.6,8 shows the experimental results of Scherer et al of excitation of I2 using pairs of phase locked pulses. By the use of heterodyne detection, those authors were able to measure just the mterference contribution to the total excited-state fluorescence (i.e. the difference in excited-state population from the two units of population which would be prepared if there were no interference). The basic qualitative dependence on time delay and phase is the same as that predicted by the hannonic model significant interference is observed only at multiples of the excited-state vibrational frequency, and the relative phase of the two pulses detennines whether that interference is constructive or destructive. Figure Al.6,8 shows the experimental results of Scherer et al of excitation of I2 using pairs of phase locked pulses. By the use of heterodyne detection, those authors were able to measure just the mterference contribution to the total excited-state fluorescence (i.e. the difference in excited-state population from the two units of population which would be prepared if there were no interference). The basic qualitative dependence on time delay and phase is the same as that predicted by the hannonic model significant interference is observed only at multiples of the excited-state vibrational frequency, and the relative phase of the two pulses detennines whether that interference is constructive or destructive.
In addition to tire standard model systems described above, more exotic particles have been prepared witli certain unusual properties, of which we will mention a few. For instance, using seeded growtli teclmiques, particles have been developed witli a silica shell which surrounds a core of a different composition, such as particles witli magnetic [12], fluorescent [13] or gold cores [14]. Anotlier example is tliat of spheres of polytetrafluoroetliylene (PTFE), which are optically anisotropic because tire core is crystalline [15]. [Pg.2670]

One approach is to prepare a sample blank using urine known to be free of quinine. The fluorescent signal for the sample blank is subtracted from the urine sample s measured fluorescence. [Pg.432]

Precision When the analyte s concentration is well above the detection limit, the relative standard deviation for fluorescence is usually 0.5-2%. The limiting instrumental factor affecting precision is the stability of the excitation source. The precision for phosphorescence is often limited by reproducibility in preparing samples for analysis, with relative standard deviations of 5-10% being common. [Pg.432]

Nickel fluoride is used in marking ink compositions (see Inks), for fluorescent lamps (4) as a catalyst in transhalogenation of fluoroolefins (5), in the manufacture of varistors (6), as a catalyst for hydrofluorination (7), in the synthesis of XeF (8), and in the preparation of high purity elemental fluorine for research (9) and for chemical lasers (qv) (10). [Pg.214]

Electron Beam Techniques. One of the most powerful tools in VLSI technology is the scanning electron microscope (sem) (see Microscopy). A sem is typically used in three modes secondary electron detection, back-scattered electron detection, and x-ray fluorescence (xrf). AH three techniques can be used for nondestmctive analysis of a VLSI wafer, where the sample does not have to be destroyed for sample preparation or by analysis, if the sem is equipped to accept large wafer-sized samples and the electron beam is used at low (ca 1 keV) energy to preserve the functional integrity of the circuitry. Samples that do not diffuse the charge produced by the electron beam, such as insulators, require special sample preparation. [Pg.356]

Lithium Borates. Lithium metaborate [13453-69-5], LLBO2 2H20, is prepared from reaction of lithium hydroxide and boric acid. It is used as the fluxing agent for the matrix for x-ray fluorescence analytical techniques and in specialty glasses and enamels. The anhydrous salt melts at 847°C. [Pg.225]

Polymer—Cp—MCl complexes have been formed with the Cp-group covalendy bound to a polystyrene bead. The metal complex is uniformly distributed throughout the bead, as shown by electron microprobe x-ray fluorescence. Olefin hydrogenation catalysts were then prepared by reduction with butyl hthium (262). [Pg.441]

Cadmium Silicates. Cadmium orthosihcate [15857-59-2] Cd2SiO, (mp 1246°C d = 5.83 g/ inL) and cadmium metasihcate [13477-19-5] CdSiO, are both prepared by direct reaction of CdO and Si02 at 390°C under 30.4 MPa (300 atm) or at 900°C and atmospheric pressure ia steam. The materials are phosphors whea activated with Mn (IT) ioa and are both fluorescent and phosphorescent. [Pg.395]

There are many references in the patent literature to azo dyes prepared from 4- and 5-aminoisothiazoles, 3-, 5- and 7-amino-1,2-benzisothiazoles, and their quaternized derivatives. These are particularly useful in the dyeing of synthetic fibres. Isothiazole compounds have also been suggested for other industrial purposes, such as corrosion inhibitors, fireproofing agents, additives in rubber vulcanization, photographic chemicals and fluorescent whiteners in detergents. [Pg.175]

At X-ray fluorescence analysis (XRF) of samples of the limited weight is perspective to prepare for specimens as polymeric films on a basis of methylcellulose [1]. By the example of definition of heavy metals in film specimens have studied dependence of intensity of X-ray radiation from their chemical compound, surface density (P ) and the size (D) particles of the powder introduced to polymer. Have theoretically established, that the basic source of an error of results XRF is dependence of intensity (F) analytical lines of determined elements from a specimen. Thus the best account of variations P provides a method of the internal standard at change P from 2 up to 6 mg/sm the coefficient of variation describing an error of definition Mo, Zn, Cu, Co, Fe and Mn in a method of the direct external standard, reaches 40 %, and at use of a method of the internal standard (an element of comparison Ga) value does not exceed 2,2 %. Experiment within the limits of a casual error (V changes from 2,9 up to 7,4 %) has confirmed theoretical conclusions. [Pg.104]

The very low Hg concentration levels in ice core of remote glaciers require an ultra-sensitive analytical technique as well as a contamination-free sample preparation methodology. The potential of two analytical techniques for Hg determination - cold vapour inductively coupled plasma mass spectrometry (CV ICP-SFMS) and atomic fluorescence spectrometry (AFS) with gold amalgamation was studied. [Pg.171]

The complex of the following destmctive and nondestmctive analytical methods was used for studying the composition of sponges inductively coupled plasma mass-spectrometry (ICP-MS), X-ray fluorescence (XRF), electron probe microanalysis (EPMA), and atomic absorption spectrometry (AAS). Techniques of sample preparation were developed for each method and their metrological characteristics were defined. Relative standard deviations for all the elements did not exceed 0.25 within detection limit. The accuracy of techniques elaborated was checked with the method of additions and control methods of analysis. [Pg.223]

The performance of microwave-assisted decomposition of most difficult samples of organic and inorganic natures in combination with the microwave-assisted solution preconcentration is illustrated by sample preparation of carbon-containing matrices followed by atomic spectroscopy determination of noble metals. Microwave-assisted extraction of most dangerous contaminants, in particular, pesticides and polycyclic aromatic hydrocarbons, from soils have been developed and successfully used in combination with polarization fluoroimmunoassay (FPIA) and fluorescence detection. [Pg.245]


See other pages where Fluorescent preparation is mentioned: [Pg.373]    [Pg.234]    [Pg.377]    [Pg.205]    [Pg.205]    [Pg.373]    [Pg.234]    [Pg.377]    [Pg.205]    [Pg.205]    [Pg.394]    [Pg.1666]    [Pg.1770]    [Pg.1976]    [Pg.1978]    [Pg.1990]    [Pg.2482]    [Pg.2487]    [Pg.2496]    [Pg.2671]    [Pg.431]    [Pg.457]    [Pg.400]    [Pg.406]    [Pg.441]    [Pg.417]    [Pg.115]    [Pg.71]    [Pg.294]    [Pg.148]    [Pg.33]    [Pg.62]    [Pg.282]    [Pg.292]    [Pg.537]    [Pg.68]    [Pg.90]    [Pg.234]    [Pg.378]   
See also in sourсe #XX -- [ Pg.134 , Pg.135 , Pg.136 , Pg.137 , Pg.138 , Pg.139 , Pg.140 , Pg.141 , Pg.142 , Pg.143 ]




SEARCH



Atomic fluorescence sample preparation

Fluorescence detection, material preparation

Fluorescence measurements preparation

Fluorescence microscopy sample preparation

Fluorescence microscopy specimen preparation

Fluorescence spectrometry preparation

Fluorescence spectroscopy sample preparation

Fluorescent bioconjugates preparation

Fluorescent probe medium, preparation

Pharmaceutical preparation fluorescence detection

Preparation of Fluorescent Silica Nanoparticles

Preparation of Fluorescently Labeled (Strept)avidin

Preparation of samples for single molecule fluorescence spectroscopy

Sample Preparation and Fluorescent Labeling

Sample preparation fluorescence experiments

Single molecule fluorescence spectroscopy sample preparation

© 2024 chempedia.info