Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fluorescence analytical techniques

Lithium Borates. Lithium metaborate [13453-69-5], LLBO2 2H20, is prepared from reaction of lithium hydroxide and boric acid. It is used as the fluxing agent for the matrix for x-ray fluorescence analytical techniques and in specialty glasses and enamels. The anhydrous salt melts at 847°C. [Pg.225]

Fluorescence and phosphorescence are types of luminescence, ie, emission attributed to selective excitation by previously absorbed radiation, chemical reaction, etc, rather than to the temperature of the emitter. Laser-iaduced and x-ray fluorescence are important analytical techniques (see... [Pg.310]

Fluorescence. The fluorescence detection technique is often used in clinical chemistry analyzers for analyte concentrations that are too low for the simpler absorbance method to be appHed. Fluorescence measurements can be categorized into steady-state and dynamic techniques. Included in the former are the conventional simultaneous excitation-emission method and fluorescence polarization. [Pg.394]

The very low Hg concentration levels in ice core of remote glaciers require an ultra-sensitive analytical technique as well as a contamination-free sample preparation methodology. The potential of two analytical techniques for Hg determination - cold vapour inductively coupled plasma mass spectrometry (CV ICP-SFMS) and atomic fluorescence spectrometry (AFS) with gold amalgamation was studied. [Pg.171]

The most common detectors in HPLC are ultraviolet, fluorescence, electrochemical detector and diffractometer. However, despite all improvements of these techniques it seems necessary to have a more selectivity and sensitivity detector for the purposes of the medical analysis. It should be therefore improvements to couple analytical techniques like infrared IR, MS, nuclear magnetic resonance (NMR), inductively coupled plasma-MS (ICP-MS) or biospecific detectors to the LC-system and many efforts have been made in this field. [Pg.342]

The principal limitation in the use of electrophoretic techniques is the lack of availability of suitable detection systems for quantitative analysis and unequivocal identification of pesticide analytes. Traditionally, either ultraviolet/visible (UVA IS) or fluorescence detection techniques have been used. However, as with chromatographic techniques, MS should be the detection system of choice. A brief comparison of the numbers of recent papers on the application of GC/MS and LC/MS with capillary elec-trophoresis/mass spectrometery (CE/MS) demonstrates that interfaces between CE... [Pg.744]

CE is also potentially a useful alternative analytical tool for monitoring of chemicals (dyes, flame retardants and lubricants) involved in various steps of the textile fibre manufacturing process. In this area, CE compares favourably with existing techniques. CZE-MSn was used for the analysis of sulfonated azo dyes [942]. A variety of fluorescent analytes including thiazole orange dyes have been characterised by CE-FLNS [943]. [Pg.278]

Given these requirements, it emerges that a suitable analytical technique for studying provenance should provide relatively rapid results and preferably be nondestructive, enabling determination of each element, and differentiation among a large number of elements in relatively short periods of time. Techniques that fulfill these conditions for studying the provenance of pottery include several spectroscopic techniques, neutron activation and X-rays fluorescence (see Textbox 10). [Pg.284]

Chemical Analysis. The chemical composition of ancient objects is important for their authentication. The nature as well as the relative amounts of major, minor, and trace elements in any object are of use for determining the authenticity or otherwise of ceramics, glass, or alloys. A wide range of analytical techniques, depending on the nature of the material studied, have been used for this purpose, including X-rays fluorescence analysis, mass spectrometry, atomic absorption spectroscopy, and neutron activation analy-... [Pg.463]

As opposed to conventional analytical techniques, optical sensors and biosensors, particularly those employing absorption and fluorescence-based sensing materials potentially allow for measurement through transparent or semi-transparent materials in a non-destructive fashion4, 5> 9 10. Chemical sensor technology has developed rapidly over the past years and a number of systems for food applications have been introduced and evaluated with foods. [Pg.502]

Also in the literature, there is little discussion of the accuracy or reproducibility of the analytical technique used for determining the corresponding matrix and particle composition [37, 38], Various analytical methods that have been used to determine the particle concentration in the deposit include gravimetric analysis [29, 31, 39], x-ray fluorescence [5], atomic absorption spectroscopy [33, 40, 41-43], and micro-... [Pg.198]

A variety of analytical techniques are used to measure PCP, including gas chromatography-mass spectrometry (GC-MS), which has a detection limit of 7.6 pg/kg honey (Muino and Taiza.no 1991), liquid chromatography with fluorescence detection (de Ruiter et al. 1990), and liquid chromatography-electrochemistry (LC-ED) procedures (Butler and Pont 1992). At present, GC-MS is the most accurate, but LC-ED is used most frequently (Butler and Pont 1992). [Pg.1200]

ABSTRACT The aim of this study was to test portable infrared spectroscopy for non-destructive analysis of ancient construction mortar. Mortar samples from the House of the Vestals, in Pompeii, Italy, were initially examined with traditional analytical techniques, including X-ray fluorescence, X-ray diffraction and thin section analysis. These techniques were used to establish mineralogical and chemical profiles of the samples and to verify the results of experimental field methods. Results showed the lime-based binder was composed of calcite, and the volcanic sand aggregate contained clinopyroxene, plagioclase, sanidine and olivine crystals. [Pg.303]

Emission-Excitation Matrix (EEM) fluorescence spectroscopy as a nondestructive and sensitive analytical technique was successfully applied in this study to characterize DOM in landfill leachte. The DOM is composed of complex mixture of organic compounds with different fluorescence properties. In particular, the EEM profiles of DOM show two well-defined peaks at Ex/Em=320-350 /400-420 nm, Ex/Em=320-350 /420-450 nm reasonably due to the presence of two different groups of fluorophores. An additional and less intense band at Ex/Em=280-290 /320-350 nm can be assigned to aromatic amino acids and phenol-like compounds. [Pg.308]

Three analytical techniques which differ in how the primary vacancies are created share the use of such X-rays to identify the elements present. In X-ray fluorescence, the solid sample is irradiated by an X-ray beam (called the primary beam), which interacts with the atoms in the solid to create inner shell vacancies, which then de-excite via the emission of secondary or fluorescent X-rays - hence the name of the technique. The second uses a beam of electrons to create the initial vacancies, giving rise to the family of techniques known collectively as electron microscopy. The third and most recently developed instrumentation uses (usually) a proton beam to cause the initial vacancies, and is known as particle- (or proton-) induced X-ray emission (PIXE). [Pg.38]

An introductory manual that explains the basic concepts of chemistry behind scientific analytical techniques and that reviews their application to archaeology. It explains key terminology, outlines the procedures to be followed in order to produce good data, and describes the function of the basic instrumentation required to carry out those procedures. The manual contains chapters on the basic chemistry and physics necessary to understand the techniques used in analytical chemistry, with more detailed chapters on atomic absorption, inductively coupled plasma emission spectroscopy, neutron activation analysis, X-ray fluorescence, electron microscopy, infrared and Raman spectroscopy, and mass spectrometry. Each chapter describes the operation of the instruments, some hints on the practicalities, and a review of the application of the technique to archaeology, including some case studies. With guides to further reading on the topic, it is an essential tool for practitioners, researchers, and advanced students alike. [Pg.407]


See other pages where Fluorescence analytical techniques is mentioned: [Pg.223]    [Pg.305]    [Pg.223]    [Pg.305]    [Pg.177]    [Pg.177]    [Pg.772]    [Pg.78]    [Pg.2]    [Pg.144]    [Pg.533]    [Pg.181]    [Pg.366]    [Pg.179]    [Pg.79]    [Pg.91]    [Pg.313]    [Pg.589]    [Pg.60]    [Pg.418]    [Pg.740]    [Pg.48]    [Pg.51]    [Pg.370]    [Pg.7]    [Pg.434]    [Pg.334]    [Pg.374]    [Pg.298]    [Pg.378]    [Pg.85]    [Pg.207]    [Pg.234]    [Pg.108]    [Pg.347]    [Pg.216]    [Pg.520]   
See also in sourсe #XX -- [ Pg.15 ]

See also in sourсe #XX -- [ Pg.15 ]




SEARCH



Analyte fluorescence

Analytical techniques

Fluorescence techniques

Fluorescent technique