Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Field operator

The general task is to trace the evolution of the third order polarization of the material created by each of the above 12 Raman field operators. For brevity, we choose to select only the subset of eight that is based on two colours only—a situation that is connnon to almost all of the Raman spectroscopies. Tliree-coloiir Raman studies are rather rare, but are most interesting, as demonstrated at both third and fifth order by the work in Wright s laboratory [21, 22, 23 and 24]- That work anticipates variations that include infrared resonances and the birth of doubly resonant vibrational spectroscopy (DOVE) and its two-dimensional Fourier transfomi representations analogous to 2D NMR [25]. [Pg.1186]

Checking field operating conditions 26/841 List of formulae used 26/843... [Pg.827]

Field Operations and Enforcement Manual for Air Pollution Control," Vol. B, "Control Technology and General Source Inspection," APTD-1101. U.S. Environmental Protection Agency, Research Triangle Park, NC, 1972. [Pg.487]

This graphical method was developed for field operations personnel. It is designed for sour natural gas at 100 to 4,000 psia up to 50% H2S or sweet gas with C3 up to 10%. [Pg.364]

The operational test of the lube system is, as the name implies, a functional test to check as many of the features as practical under running conditions. The first and last step is a demonstration of the cleanliness of the system. This is followed by a running test of a four-hour duration. The test should simulate the field operation with the compressor in every way practical. All equipment to be furnished with the lube system should be used in the test, including the standby pump start and trip switches. All other instruments should be used to demonstrate their operation. Prior to starting the four-hour run, the system should be thoroughly inspected for leaks and the leaks corrected. If no steam is available for a steam turbine (if one is used), the four-hour run can be made on the electric pump. However, every effort should be made to use an alternate source of energy such as compressed air, to operate the steam turbine. [Pg.415]

The advent of ISO 9000 certification has helped bring the quality issue to a focus. While ISO 9000 emphasis is on documentation of methodology and performance to the documented methods, the discipline that results is a direct step toward improvements in reliability. Out of this seems to come a goal of continuous improvement. This is a sharp contrast to the high growth era that took place in the early 1980s when poor quality on the part of the equipment suppliers was a significant factor in the lack of reliability at the field operation level. [Pg.488]

Database for management of sanitary and storm wastewater collection systems. Maintains field operations data including safety history, engineering data, inspection recoids, and work orders. Requires 640K memory and hard disk. [Pg.300]

BPCS/SIS functions that produce a trend analysis of input and output functions. Graphic video displays set-up to indicate process conditions and valve positions assure that the status of the process conditions is announced to the board operator, who may then verify the conditions with the field operator. [Pg.82]

Any site-related activities such as bench-scale laboratory and R D activities should comply with the OSHA Laboratory Standard (29 CER 1910.1450). R D activities involving pilot- or full-scale field operations should comply with HAZWOPER when there is reasonable possibility for worker exposure to hazardous wastes or substances or emergency response. [Pg.20]

This section addresses aspects of the task which influence human reliability in both control-room and field operation situations. It includes the physical equipment to be used, control panels, job-aids and procedures, and the type of training provided. [Pg.119]

The experienced field operator has observed water and gas being emitted from the hydrocarbon vent at the cooling tower. The field operator shouts over the radio that a propane vapor cloud appears to be forming and moving towards the control room. [Pg.231]

The control room operator has directed the field operator to isolate the failed condenser as quickly as possible so that a imit shutdown will not be necessary. [Pg.231]

The field operator has correctly identified the condenser with the failed tube by the sound of the expanding propane and the visible condensation/frost on the shell. [Pg.231]

There is a field operation method by which the fracture pressure gradient can be experimentally verified. Such tests are known as leak-off tests. The leak-off test will be discussed in Chapter 4. [Pg.266]

This chapter describes the various auxiliary equipment that are important to the function of oil field activities. This equipment is used in drilling, well completion, production, and related operations. The discussions that follow will concentrate on the basic operation characteristics and specifications required by a user. The aim is to give the user the information needed to ascertain whether the equipment available for a particular field operation is adequate, or if the equipment available is not adequate, how to specify what equipment will be necessary. [Pg.393]

The API standards describe the method used in rating engines and the recommended practice for engine installation, maintenance, and operation [2,3]. In oil field operations the API rating standards are most frequently used. [Pg.395]

When a wire rope is operated close to the minimum design factor, the rope and related equipment should be in good operating condition. At all times, the operating personnel should minimize shock, impact, and acceleration or deceleration of loads. Successful field operations indicate that the following design factors should be regarded as minimum ... [Pg.584]

Okpobiri, G. A., C. J. Machado, and C. U. Ikoku, Minimum Volumetric Requirements in Aerated Drilling A Field Operations Manual, U.S. Department of Energy Report No. DOE/BC/10079-49, December 1982. [Pg.1377]

Vennett, R. M., Corrosion Monitoring in Oil Field Operations Using a Vacuum Hydrogen Probe , Materials Performance, 16, 8, 31-41 (1977)... [Pg.1150]

The covariant amplitudes describing one-, two-, etc., particle systems can be defined in terms of the Heisenberg field operators (x) as follows oonsider a one-particle system described by the state vector IT) Since it describes a one-particle system, it has the property that... [Pg.511]

For a discussion of the transformation of the field operators under improper Lorentz transformations and discrete symmetry operations such as charge conjugation, see ... [Pg.547]

Quantization of the Electromagnetic Field.—Instead of proceeding as in the previous discussion of spin 0 and spin particles, we shall here adopt essentially the opposite point of view. Namely, instead of formulating the quantum theory of a system of many photons in terms of operators and showing the equivalence of this formalism to the imposition of quantum rules on classical electrodynamics, we shall take as our point of departure certain commutation rules which we assume the field operators to satisfy. We shall then show that a... [Pg.560]

We postulate the equal time commutation rules for the field operators to be... [Pg.562]

In a manner similar to the above, one verifies that the commutation rules (9-587) and (9-588) guarantee that P as given by Eq. (9-581) is the generator for an infinitesimal spatial translation in the sense that Eq. (9-583) is satisfied for the field operators. Similarly, one verifies that the three components of the vector operator... [Pg.563]

We next investigate the representation of the field operators in terms... [Pg.574]

If if>ln(x), to(x) are the fermion field operators discussed at length above, then... [Pg.607]

In the Heisenberg picture the electromagnetic field operators satisfy the equations of motion... [Pg.642]

If we decompose the electric field operator into a transverse and longitudinal part... [Pg.642]


See other pages where Field operator is mentioned: [Pg.610]    [Pg.237]    [Pg.238]    [Pg.329]    [Pg.394]    [Pg.841]    [Pg.81]    [Pg.300]    [Pg.598]    [Pg.400]    [Pg.476]    [Pg.254]    [Pg.139]    [Pg.110]    [Pg.668]    [Pg.396]    [Pg.145]    [Pg.47]    [Pg.587]    [Pg.608]    [Pg.609]   
See also in sourсe #XX -- [ Pg.269 ]

See also in sourсe #XX -- [ Pg.22 , Pg.25 ]

See also in sourсe #XX -- [ Pg.2 , Pg.351 , Pg.443 ]




SEARCH



© 2024 chempedia.info