Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Elemental activation analysis

The method yields only gross sample elemental abundances and by itself does not permit distinguishing between different chemical states of an element in mixtures. For many elements, activation analysis is the most sensitive analytical technique available. It is the purpose of this paper to show that recent advances in instrumentation now make possible accurate, rapid, and often non-destructive determinations of elemental abundances by this technique and that it should be included among the routine analytical tools available in any modem analytical facility. [Pg.50]

Biologkal Trace Elements, Activation Analysis of (Leddicotte). 19 345... [Pg.250]

Lux, F. and Zeisler, R. (1974) Investigations of the corrosive deposition of components of metal implants and of the behavior of biologic trace elements in metallosis tissue by means of instrumental, multi-element activation analysis. J. Radiol. Anal Chem., 19, 289-297. [Pg.541]

Neutron Activation Analysis Few samples of interest are naturally radioactive. For many elements, however, radioactivity may be induced by irradiating the sample with neutrons in a process called neutron activation analysis (NAA). The radioactive element formed by neutron activation decays to a stable isotope by emitting gamma rays and, if necessary, other nuclear particles. The rate of gamma-ray emission is proportional to the analyte s initial concentration in the sample. For example, when a sample containing nonradioactive 13AI is placed in a nuclear reactor and irradiated with neutrons, the following nuclear reaction results. [Pg.645]

Trace-element analysis of metals can give indications of the geographic provenance of the material. Both emission spectroscopy (84) and activation analysis (85) have been used for this purpose. Another tool in provenance studies is the measurement of relative abundances of the lead isotopes (86,87). This technique is not restricted to metals, but can be used on any material that contains lead. Finally, for an object cast around a ceramic core, a sample of the core material can be used for thermoluminescence dating. [Pg.421]

Elemental chemical analysis provides information regarding the formulation and coloring oxides of glazes and glasses. Energy-dispersive x-ray fluorescence spectrometry is very convenient. However, using this technique the analysis for elements of low atomic numbers is quite difficult, even when vacuum or helium paths are used. The electron-beam microprobe has proven to be an extremely useful tool for this purpose (106). Emission spectroscopy and activation analysis have also been appHed successfully in these studies (101). [Pg.422]

Trace-element analysis, using emission spectroscopy (107) and, especially, activation analysis (108) has been appHed in provenance studies on archaeological ceramics with revolutionary results. The attribution of a certain geographic origin for the clay of an object excavated elsewhere has a direct implication on past trade and exchange relationships. [Pg.422]

MetaUic impurities in beryUium metal were formerly determined by d-c arc emission spectrography, foUowing dissolution of the sample in sulfuric acid and calcination to the oxide (16) and this technique is stUl used to determine less common trace elements in nuclear-grade beryUium. However, the common metallic impurities are more conveniently and accurately determined by d-c plasma emission spectrometry, foUowing dissolution of the sample in a hydrochloric—nitric—hydrofluoric acid mixture. Thermal neutron activation analysis has been used to complement d-c plasma and d-c arc emission spectrometry in the analysis of nuclear-grade beryUium. [Pg.69]

Instiximental neutron activation analysis (INAA) is considered the most informative and highly sensitive. Being applied, it allows detecting and determination of 30-40 elements with the sensitivity of 10 -10 g/g in one sample. The evident advantage of INAA is the ability to analyze samples of different nature (filters, soils, plants, biological tests, etc.) without any complex schemes of preliminai y prepai ation. [Pg.77]

CONTENTS OF ELEMENTS IN DRIED GRAPE RAW, MEASURED BY GAMMA-ACTIVATION ANALYSIS... [Pg.441]

The chemical composition of particulate pollutants is determined in two forms specific elements, or specific compounds or ions. Knowledge of their chemical composition is useful in determining the sources of airborne particles and in understanding the fate of particles in the atmosphere. Elemental analysis yields results in terms of the individual elements present in a sample such as a given quantity of sulfur, S. From elemental analysis techniques we do not obtain direct information about the chemical form of S in a sample such as sulfate (SO/ ) or sulfide. Two nondestructive techniques used for direct elemental analysis of particulate samples are X-ray fluorescence spectroscopy (XRF) and neutron activation analysis (NAA). [Pg.205]

Atomic absorption spectroscopy of VPD solutions (VPD-AAS) and instrumental neutron activation analysis (INAA) offer similar detection limits for metallic impurities with silicon substrates. The main advantage of TXRF, compared to VPD-AAS, is its multielement capability AAS is a sequential technique that requires a specific lamp to detect each element. Furthermore, the problem of blank values is of little importance with TXRF because no handling of the analytical solution is involved. On the other hand, adequately sensitive detection of sodium is possible only by using VPD-AAS. INAA is basically a bulk analysis technique, while TXRF is sensitive only to the surface. In addition, TXRF is fast, with an typical analysis time of 1000 s turn-around times for INAA are on the order of weeks. Gallium arsenide surfaces can be analyzed neither by AAS nor by INAA. [Pg.355]

In many industrial halls, conduction inro the ground is a major factor for heat loss. Therefore, an adequate modeling of the floor slab and the underlying, thermally active, soil is very crucial for reliable simulation resuirs. In this case, the soil model in the TRNSYS model was established using results from an additionally performed finite-element program analysis. [Pg.1078]

Nitronium tetrafluoroborate is very hygroscopic. It is stable as long as it is anhydrous, but it is decomposed by moisture, and all transfers should be in a dry box. Its purity can be checked by conventional elemental analysis. However, because of the hygroscopic nature of the salt, the submitters have found it convenient to use neutron activation analysis (B, F, N, O) of samples... [Pg.59]

In the modern forensic chemistry laboratory (Figure B) arsenic is detected by analysis of hair samples, where the element tends to concentrate in chronic arsenic poisoning. A single strand of hair is sufficient to establish the presence or absence of the element. The technique most commonly used is neutron activation analysis, described in Chapter 19. If the concentration found is greater than about 0.0003%, poisoning is indicated normal arsenic levels are much lower than this. [Pg.573]

H. Kramer, S. Semel J.E. Abel, Trace Elemental Survey Analysis of Trinitrotoluene , PATR 4767 (1975) (An evaluation of the applicability of spark source mass spectrometry and thermal neutron activation for the detn of origin-related trace elemental impurities in TNT) 10) C. Ribando J. Haber-man, Origin-Identification of Explosives Via Their Composite Impurity Profiles I. The... [Pg.141]

G.J. McCallum, Determination of Trace Elements by Activation Analysis With Charged Particles , JSci 12 (3), 470-5 (1969) CA 70, 97975 (1969) 52) Anon, Analysis of... [Pg.303]

Nuclear activation analysis (NAA) is a method for qualitatively and quantitatively detg elemental compn by means of nuclear transmutations. The method involves the irradiation or bombardment of samples with nuclear particles or high-energy electromagnetic radiation for the specific purpose of creating radioactive isotopes from the stable or naturally-occurring elements present. From the numbers, types and quantities of radioactive elements or radionuclides, it is possible to deduce information about the elemental compn of the original sample... [Pg.356]

This can result in a radioactive product from the A(n, t)A reaction where A is the stable element, n is a thermal neutron, A is the radioactive product of one atomic mass unit greater than A, and y is the prompt gamma ray resulting from the reaction. A is usually a beta and/or gamma emitter of reasonably long half-life. Where access to a nuclear reactor has been convenient, thermal neutron activation analysis has proven to be an extremely valuable nondestructive analytical tool and in many cases, the only method for performing specific analyses at high sensitivities... [Pg.356]

Individual sources of 252Cf are currently available in quantities up to 10—50mgs of the element. Such sources, when contained in a suitable hydrogenous moderator, can provide thermal neutron outputs adequate for the activation analysis of many elements in the fraction of a percent wt range... [Pg.357]

Elemental Analysis, 2) Determination of Pellet Weight in Primers, 3) Determination of Gunpowder Residues in Forensic.Investigations, 4) Detection of Explosives in Buried Mines, 5) Detection of Hidden Explosives in Baggage, and 6) Explosives Safety in Neutron Activation Analysis... [Pg.357]

The apphed pretreatment techniques were digestion with a combination of acids in the pressurized or atmospheric mode, programmed dry ashing, microwave digestion and irradiation with thermal neutrons. The analytical methods of final determination, at least four different for each element, covered all modern plasma techniques, various AAS modes, voltammetry, instrumental and radiochemical neutron activation analysis and isotope dilution MS. Each participating laboratory was requested to make a minimum of five independent rephcate determinations of each element on at least two different bottles on different days. Moreover, a series of different steps was undertaken in order to ensure that no substantial systematic errors were left undetected. [Pg.65]

Certification of Element Contents by Neutron Activation Analysis... [Pg.66]

Byrne AR, Deemelj M, Kosta L, and Tusek-Znidaric M (1984) Radiochemical neutron activation analysis in standardization of trace elements in biological reference materials at the nanogram level. Mikrochim Acta [Wien] 1 119-126. [Pg.102]

Delfanti R, Di Casa M, Gallorini M, and Orvini E (1984) Five years activity in determining trace elements for the certification of standard reference materials by neutron activation analysis. Mikrochim Acta [Wien] L239-250. [Pg.103]

Heydorn K (1984) Neutron Activation Analysis for Chemical Trace Element Research. CRC Press, Boca Raton, Florida. [Pg.104]

Kucera j (1995) Elemental characterization of new Polish and US NIST geological, environmental and biological reference materials by neutron activation analysis and comments on the methodology of interlaboratory comparisons. Chem Anal (Warsaw) 40 405-421. [Pg.106]


See other pages where Elemental activation analysis is mentioned: [Pg.28]    [Pg.28]    [Pg.14]    [Pg.209]    [Pg.423]    [Pg.244]    [Pg.425]    [Pg.205]    [Pg.441]    [Pg.51]    [Pg.671]    [Pg.236]    [Pg.516]    [Pg.292]    [Pg.4]    [Pg.66]    [Pg.68]    [Pg.70]   
See also in sourсe #XX -- [ Pg.773 ]