The electrical distribution system design and equipment selection must consider requirements of the utility company for protection and metering. Available short circuit currents from the utility distribution network to the primary of the facility s main transfoiTner must be considered in selecting circuit protection devices for the facility distribution system. [Pg.495]

NFPA 70 National Fire Protection Association 70 is also known as the National Electric Code (NEC). Revisions and addendum s to the code are currently being developed that specifically address fuel cells. Article 690 - Solar Photovoltaic Systems has been targeted for revision to include fuel cells and alternate energy sources systems. This proposal is not expected to be approved since the technological and operational differences between fuel cells and photovoltaic systems is considerable. A new article, currently identified and Article 691, has been proposed and applies to fuel cells for buildings or residential dwellings. This standard addresses the electrical interface between the fuel cell system and a building s electrical distribution panel. [Pg.337]

Electric power distribution Fuel oil and fuel gas facilities Water supply and disposal Plant air systems Fire protection systems... [Pg.309]

The evaluation of field of current density is essential in problems of galvanic corrosion. In many cases the direct measurement of current density is not feasible, while the electric potential can be obtained from experimental measurements. This is particularly true in case of cathodic protection systems in general, where many surveying techniques (for example DCVG and CIS for underground structures) rely in potential measurements at different points at the electrolyte in order to identify the current distribution along the metallic structures. [Pg.173]

Electrical Distribution Systems. Starting at the source of power supply, the basic electrical system includes transmission, substation, transformation, switching, distribution by feeders, the items of use, and protective safety equipment. Electrical flow sheets are prepared, using... [Pg.421]

Electrical Equipment Protection. Equipment must be constantly protected against excessively high currents from short circuits or faulty operation. Circuit breakers which open the circuit automatically on overload are sized and installed throughout the entire distribution system, including both primary and secondary systems. The design philosophy is to confine the interruption to the piece of equipment or circuit at fault, thereby avoiding interruption of an entire plant. [Pg.424]

Recloser (Fig. 4) is a modem power switching component, capable of breaking short-circuit currents and earth fault currents, based on data obtained from an adequate and comprehensive protection system. The utilization of Reclosers causes acceleration in handling and thus shortening of duration of a fault in the electrical distribution networks and leads to improved rehabihty of electrical energy supply. As the funds provided for replacement of section switches for Reclosers are often limited, it is necessary to proceed with replacement at the most needed places of distribution network. [Pg.154]

Electricity distribution system - Low voltage (LV) overhead lines - Medium voltage (MV) overhead lines - High voltage (FTV) overhead lines - MV/LV substations - HV/MV primary substations - Protection and control equipment... [Pg.385]

Compared with present-day LWR plants, the electric power supply systems of PIUS have been simplified significantly. The main reason for that is obviously the "inherent" self-protective functions of PIUS that eliminate many traditional safety-grade systems or reduce their importance to such extent that they can be declassified. Thus, a "two trmn" electrical supply system structure has been found fully acceptable with respect to safety and plant availability concerns. In order to improve the reliability of the power supply for important process functions, e.g. for protection of the capital investment, low voltage diesel generators are provided in the PIUS plant, but they are not safety-grade. The elimination of most of the DC distributions represents another major simplification of the electrical power supply system. [Pg.242]

Control of External Corrosion on Underground or Submerged Metallic Piping Systems Design, Installation, Operation, and Maintenance of Impressed Current Deep Groundbeds Corrosion Control of Electric Underground Residential Distribution Systems Design, Installation, Operation, and Maintenance of Internal Cathodic Protection Systems in Oil... [Pg.859]

The available short-circuit current at any point in an electrical system is the worst-case or maximum short-circuit current that can flow under fault conditions. To safely apply overcurrent devices within their interrupting ratings, it is necessary to calculate the available short circuit currents at various points of application in an electrical distribution system.The procedure to calculate the magnitude of the fault current is described in various publications available from circuit protective device manufacturers. [Pg.666]

From point of service to point of use, electric power is directed, protected, and modified by segments of the system whose function, performance, and efficiency are vital to the utilizing equipment. To operate and maintain an industrial electric distribution system properly and to understand system planning fully, it is necessary to comprehend the function of each system component and its place in the overall system. Continued reference to Fig. 5.147, the one-line diagram, will aid in putting the various elements of the system into proper perspective. [Pg.702]

From the electric point of view, designing cathodic protection installations is based on the determination of the spatial distribution of the electric field intensity between anodes and the protected structure as the cathode. Classic cathodic protection systems operate in ohmic control conditions (Morgan, 1987 Benedict, 1986). This means that the resistance magnitude between anodes and the protected structure is a factor affecting the distribution of electric field force lines. The transfer resistance between the anode and the electrolytic environment connected with electrochemical reactions, and the transfer resistance between the electrolytic environment and the cathode, are usually insignificantly small in relation to the... [Pg.448]

Security is defined as a system of measures, forms, and methods for protection against destructive effects on human and material values. This is mostly initiated by man. Man affects an object, material, and environment with the aim to cause intentional loss through these subjects Civil security also includes minimizing the consequences of risks that occur as a result of major industrial accidents, or negative events that may seriously threaten third parties, for example, the failure of energy distribution media (gas pipeline, oil pipeline, electricity distribution system, etc.). [Pg.163]

In a cathodic protection system, in electrically non-conductive material, such as a coating, plastic sheet or pipe, that is placed between an anode and an adjacent cathode to avoid current wastage and to improve current distribution, usually on the cathode. [Pg.480]

Electrical. The plant electrical system is sometimes more important than the steam system. The electrical system consists of the utihty company s entry substation, any ia-plant generating equipment, primary distribution feeders, secondary substations and transformers, final distribution cables, and various items of switch-gear, protective relays, motor starters, motors, lighting control panels, and capacitors to adjust power factor. [Pg.227]

Now let us consider utility failure as a cause of overpressure. Failure of the utility supphes (e.g., electric power, cooling water, steam, instrument air or instrument power, or fuel) to refinery plant facihties wiU in many instances result in emergency conditions with potential for overpressuring equipment. Although utility supply systems are designed for reliability by the appropriate selection of multiple generation and distribution systems, spare equipment, backup systems, etc., the possibility of failure still remains. Possible failure mechanisms of each utility must, therefore, be examined and evaluated to determine the associated requirements for overpressure protection. The basic rules for these considerations are as follows ... [Pg.125]

See also-. Climatic Effects Consumption Domestic Energy Use Electric Motor Systems Electric Power, Generation of Electric Power, System Protection, Control, and Monitoring of Electric Power Substations Electric Power Transmission and Distribution Systems Government and the Energy Marketplace Regulation and Rates for Electricity. [Pg.427]

Function and Scope of IC Packaging. The package of an electronic system performs several functions. The package must mechanically support the ICs, protect the ICs from adverse environmental effects, distribute electrical power, remove heat from the chips, and provide signal interconnections between the ICs and the rest of the system. [Pg.451]


See other pages where Electricity distribution protection systems is mentioned: [Pg.476]    [Pg.288]    [Pg.157]    [Pg.173]    [Pg.331]    [Pg.360]    [Pg.118]    [Pg.90]    [Pg.154]    [Pg.221]    [Pg.347]    [Pg.458]    [Pg.409]    [Pg.964]    [Pg.402]    [Pg.1]    [Pg.72]    [Pg.479]    [Pg.215]    [Pg.240]    [Pg.214]    [Pg.955]    [Pg.227]    [Pg.17]    [Pg.499]    [Pg.308]    [Pg.413]    [Pg.250]   


SEARCH



Distribution system

Electric distribution

Electrical protection

Electrical system

Electricity distribution protection systems applications

Protection systems

Protection systems, electrical

Protective systems

© 2024 chempedia.info