Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Dilution, liquid chromatography

Chao M. et al., 2005. Rapid and sensitive quantification of urinary N7-mthelguanine by isotope-dilution liquid chromatography/electrospray ionization tandem mass spectrometry with online solid-phase extraction. Rapid Commun Mass Spectrom 19 2427. [Pg.294]

Hu C. et al., 2006. Clinical-scale high-throughput analysis of urinary 8-oxo-7,8-dihydro-2 -deoxyquanosine by isotope-dilution liquid chromatography-tandem mass spectrometry with online sohd-phase extraction. Clin Chem 52 7. [Pg.295]

Tai SS, Welch MJ. 2000. Determination of ll-nor-delta9-tetrahydrocannabinol-9-carboxylic acid in a urine-based standard reference material by isotope-dilution liquid chromatography-mass spectrometry with electrospray ionization. J Anal Toxicol 24 385. [Pg.175]

Grace, P.B., Taylor, J.I., Bolting, N.P., et al. (2003). Quantification of isoflavones and lignans in serum using isotope dilution liquid chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom., 17, 1350-1357. [Pg.106]

Vanderford BJ, Snyder SA (2006) Analysis of pharmaceuticals in water by isotope dilution liquid chromatography/tandem mass spectrometryf. Environ Sci Technol 40 7312-7320... [Pg.69]

Frederiksen H, Jorgensen N, Andersson AM (2010) Correlations between phthalate metabolites in urine, serum, and seminal plasma from young Danish men determined by isotope dilution liquid chromatography tandem mass spectrometry. J Anal Toxicol 34 400-410... [Pg.295]

Jansen, E. E. W., Gibson, K. M., Shigematsu, Y., Jakobs, C., and Verhoeven, N. M. (2006). A novel, quantitative assay for homocamosine in cerebrospinal fluid using stable-isotope dilution liquid chromatography-tandem mass spectrometry. J. Chromatogr. B Arnlyt. Technol. Biomed. Life Sci. 830,196-200. [Pg.142]

Clarke, D.B., Lloyd, A.S., Botting, N.P., Oldfield, M.F., Needs, P.W., and Wiseman, H., Measurement of intact sulfate and glucuronide phytoestrogen conjugates in human urine using isotope dilution liquid chromatography-tandem mass spectrometry with [13C(3)]isoflavone internal standards, Anal. Biochem., 309, 158, 2002. [Pg.356]

Gellekink H, van Oppenraaij-Emmerzaal D, van Rooij A, Struys EA, den Heijer M, Blom HJ (2005) Stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry method for fast, selective measurement of S-adenosylmethionine and S-adeno-sylhomocysteine in plasma. Clin Chem 51 1487-1492... [Pg.114]

Guo T, Taylor RL, Singh RJ, Soldin SJ (2006) Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry. Clin Chim Acta 372 76-82... [Pg.601]

Rodriguez-Cabaleiro D, van Uytfanghe K, Stove V, Fiers T, Thienpont LM (2007) Pilot study for the standardization of insulin immunoassays with isotope dilution liquid chromatography/ tandem mass spectrometry. Clin Chem 53 1462-1469... [Pg.123]

Thienpont LM, Van Uytfanghe K, Blincko S, Ramsay CS, Xie H, Doss RC et al (2008) State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry. Clin Chem 54 1290-1297... [Pg.124]

Tai SS-C, Xu B, Welch MJ, Phinney KW (2007) Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry. Anal Bioanal Chem 388 1087-1094... [Pg.283]

Daly, J.D., O Hehir, C.M. (2007). A sensitive method for quantitation ofheta-lyase metabolites of sulfur mustard as l,l -sulfonylbis[2-(methylthio)ethane] (SBMTE) in human urine by isotope dilution liquid chromatography-positive ion-electrospray-tandem mass spectrometry. J. Chromatogr. B 850 120-7. [Pg.785]

Ford RE, Magera MJ, Kloke KM, Chezick PA, Fauq A, McConnell JP. Quantitative measurement of porphobilinogen in urine by stable-isotope dilution liquid chromatography-tandem mass spectrometry. Clin Chem 2001 47 1627-32. [Pg.1231]

G Singh, V Arora, PT Fenn, B Mets, IA Blair. A validated stable isotope dilution liquid chromatography tandem mass spectrometry assay for trace analysis of cocaine and its major metabolites in plasma. Anal Chem 71 2021—2027, 1999. [Pg.349]

Cawood, M.L., Field, H.P., Ford, C.G., Gillingwater, S., Kiernan, A., Cowan, D. and Barth, J.H. (2005). Testosterone measurement by isotope-dilution liquid chromatography-tandem mass spectrometry validation of a method for routine clinical practice. Clin. Chem., 51, 1472-1479. [Pg.29]

Mitamura, K., Nagaoka, Y., Shimada, K., Honma, S., Namiki, M., Koh, E. and Mizokami, A. (2003). Simultaneous determination of androstenediol 3-sulfate and dehydroepiandrosterone sulfate in human serum using isotope diluted liquid chromatography-electrospray ionization-mass spectrometry. J. Chromatogr. B, 796, 121-130. [Pg.31]

Ruan, Q., Kim, H. Y, Jiang, H., Penning, T. M., Harvey, R. G., and Blair, I. A. (2006). Quantification of benzo[a]pyrene diol epoxide DNA-adducts by stable isotope dilution liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom 20, 1369—1380. [Pg.189]

Detection and quantitation of PAH-derived DNA adducts requires authentic synthetic standards to act as internal standards and therefore a knowledge of adduct structure. Adduct structure can often be used to provide information on the mechanism of PAH activation that must have occurred. Unfortunately, this is quite challenging since PAH-DNA adducts can be difficult to detect and quantitate since they may be present in only 1 108 nucleotides. State-of-the art methods requiring stable isotope dilution liquid chromatography/multiple reaction monitoring/mass spectrometry (LC/MRM/MS) are necessary to provide sufficient sensitivity to detect these adducts reliably. Additionally, PAH-DNA adducts have different rates of repair and yield different rates of mutation. Thus, each adduct must be assessed so that it can be ranked according to its half-life and miscoding potential. [Pg.133]

Kim, M.-J. and Y.-H. Kim Determination of phenols in mainstream cigarette smoke by isotope dilution liquid chromatography/electrospray ionization tandem mass spectrometer 61st Tobacco Science Research Conference, Program Booklet and Abstracts, Vol. 61, Paper No. 20, 2007, pp. 26-27. [Pg.1444]

Doerge, D.R., Burger, M.W. and Bajic, S., Isotope dilution liquid chromatography-mass spectrometry using a particle beam interface, Anal. Chem., 64, 1212-1216 (1992). [Pg.48]

Mohamed R, Hammel YA, LeBreton MH, Tabet JC, Jullien L, Guy PA, Evaluation of atmospheric pressure ionization interfaces for quantitative measurement of sulfonamides in honey using isotope dilution liquid chromatography coupled with tandem mass spectrometry techniques, J. Chromatogr. A 2007 1160(l-2) 194-205. [Pg.223]

Mottier P, Hure I, Gremaud E, Guy P, Analysis of four 5-nitroimidazoles and their corresponding hydroxylated metabolites in egg, processed egg, and chicken meat by isotope dilution liquid chromatography tandem mass spectrometry, J. Agric. Food Chem. 2006 54 2018-2026. [Pg.257]

Ciccimaro E, Hanks SK, Yu KH, Blair lA. Absolute quantification of phosphorylation on the kinase activation loop of cellular focal adhesion kinase by stable isotope dilution liquid chromatography/mass spectrometry. Anal Chem 2009 81 3304—3313. [Pg.674]

Zhu P, Oe T, Blair lA. Determination of cellular redox status by stable isotope dilution liquid chromatography/mass spectrometry analysis of glutathione and glutathione disulfide. Rapid Commun. Mass Spectrom 2008 22 432-440. [Pg.684]

Jung, P.G. Kim, B. Park, S.R. So, H.Y. Shi, L.H. Kim, Y. Determination of serum cortisol using isotope dilution-liquid chromatography-mass spectrometry as a candidate reference method. Anal. Bioanal. Chem. 2004, 380 (5-6), 782-788. [Pg.231]

Maunsell, Z. Wrighf D.J. Rainbow, SJ. Routine isotope-dilution liquid chromatography tandem mass spectrometry assay for simultaneous measurement of the 25-hydroxy metabolites of vitamins D2 and D3. CHn. Chem. 2005, 51 (9), 1683-1690. [Pg.232]

Ren, Y. P., Zhang, Y., Jiao, J. J., and Cai, Z. X. 2006. Sensitive isotope dilution liquid chromatography/electrospray ionization tandem mass spectrometry method for the determination of acrylamide in chocolate. FoodAddit. Contam. 23 228-36. [Pg.83]

Holder, C. L., Preece, S. W., Conway, S. C., Pu, Y. M., and Doerge, D. R. 1997. Quantification of heterocyclic amine carcinogens in cooked meats using isotope dilution liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry. Rapid Commun. Mass Spectrom. 11 1667-1672. [Pg.170]

Riediker, S., and Stadler, R. H. 2003. Analysis of acrylamide in food using isotope-dilution liquid chromatography coupled with electrospray ionization tandem mass spectrometry, J. Chrom. A., 1020 121—130. [Pg.356]

Zhang, Y, Ren, Y, Zhao, H., and Zhang, Y. 2007. Determination of acrylamide in Chinese traditional carbohydrate-rich foods using gas chromatography with microelectron capture detector and isotope dilution liquid chromatography combined with electrospray ionization tandem mass spectrometry. Anal. Chim. Acta. 584 322-332. [Pg.357]

Jung, M., Kim, B., Boo, D.W., and So, H.-Y., 2007. Development of isotope dilution-liquid chromatography/tandem mass spectrometry as a candidate reference method for the determination of folic acid in infant milk formula. Bulletin of the Korean Chemical Society. 2007 745-750. [Pg.448]

Mitamura K et al (2007) Determination of digoxin in human serum using stable isotope dilution liquid chromatography/electrospray ionization-tandem mass spectrometry. Biol Pharm Bull 30 1653-1656... [Pg.14]

Lim YO, Kim B, Ahn S, Kim J. Improvement of accuracy for the determination of vitamin A in infant formula by isotope dilution—liquid chromatography/tandem mass spectrometry. Food Chem 2011 126 1393—8. [Pg.515]

Phinney KW, Rimmer CA, Thomas JB, Sander LC, Sharpless KE, Wise SA. Isotope dilution liquid chromatography—mass spectrometry methods for fat- and water-soluble vitamins in nutritional formulations. Anal Chem 2001 83 92-8. [Pg.517]


See other pages where Dilution, liquid chromatography is mentioned: [Pg.316]   
See also in sourсe #XX -- [ Pg.264 ]




SEARCH



Chromatography dilution

Isotope dilution with liquid chromatography mass

Liquid chromatography dilution assays

© 2024 chempedia.info