Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Detection activation analysis

Because of the increasing emphasis on monitoring of environmental cadmium the detemiination of extremely low concentrations of cadmium ion has been developed. Table 2 Hsts the most prevalent analytical techniques and the detection limits. In general, for soluble cadmium species, atomic absorption is the method of choice for detection of very low concentrations. Mobile prompt gamma in vivo activation analysis has been developed for the nondestmctive sampling of cadmium in biological samples (18). [Pg.393]

The detection and determination of traces of cobalt is of concern in such diverse areas as soflds, plants, fertilizers (qv), stainless and other steels for nuclear energy equipment (see Steel), high purity fissile materials (U, Th), refractory metals (Ta, Nb, Mo, and W), and semiconductors (qv). Useful techniques are spectrophotometry, polarography, emission spectrography, flame photometry, x-ray fluorescence, activation analysis, tracers, and mass spectrography, chromatography, and ion exchange (19) (see Analytical TffiTHODS Spectroscopy, optical Trace and residue analysis). [Pg.371]

Instiximental neutron activation analysis (INAA) is considered the most informative and highly sensitive. Being applied, it allows detecting and determination of 30-40 elements with the sensitivity of 10 -10 g/g in one sample. The evident advantage of INAA is the ability to analyze samples of different nature (filters, soils, plants, biological tests, etc.) without any complex schemes of preliminai y prepai ation. [Pg.77]

Atomic absorption spectroscopy of VPD solutions (VPD-AAS) and instrumental neutron activation analysis (INAA) offer similar detection limits for metallic impurities with silicon substrates. The main advantage of TXRF, compared to VPD-AAS, is its multielement capability AAS is a sequential technique that requires a specific lamp to detect each element. Furthermore, the problem of blank values is of little importance with TXRF because no handling of the analytical solution is involved. On the other hand, adequately sensitive detection of sodium is possible only by using VPD-AAS. INAA is basically a bulk analysis technique, while TXRF is sensitive only to the surface. In addition, TXRF is fast, with an typical analysis time of 1000 s turn-around times for INAA are on the order of weeks. Gallium arsenide surfaces can be analyzed neither by AAS nor by INAA. [Pg.355]

The neutron activation analysis of the polymer reveals that initiation is effected predominantly by chlorine atoms. No retardation or inhibition were detected,... [Pg.249]

In the modern forensic chemistry laboratory (Figure B) arsenic is detected by analysis of hair samples, where the element tends to concentrate in chronic arsenic poisoning. A single strand of hair is sufficient to establish the presence or absence of the element. The technique most commonly used is neutron activation analysis, described in Chapter 19. If the concentration found is greater than about 0.0003%, poisoning is indicated normal arsenic levels are much lower than this. [Pg.573]

Elemental Analysis, 2) Determination of Pellet Weight in Primers, 3) Determination of Gunpowder Residues in Forensic.Investigations, 4) Detection of Explosives in Buried Mines, 5) Detection of Hidden Explosives in Baggage, and 6) Explosives Safety in Neutron Activation Analysis... [Pg.357]

This feasibility study shows that determination of pellet wt by fast neutron oxygen activation analysis can be used for quality assurance inspection of M34 primers. Either direct oxygen analysis, where a comparison standard (such as lucite) is used, or a ratio method, utilizing the Cu in the cup-anvil combination as an internal standard, can be applied. In general, the uniformity of production primers is quite satisfactory, as is usually the case where production procedures are standardized. It seems likely that the light pellet is one which has been improperly manufd and will probably be well below specifications in pellet wt. Production experience with such primers indicates that only one in 3x10s primers is expected to show low pellet wt therefore, one would not expect to find a reject in a small sampling. Nevertheless, detection and rejection of this one bad unit is critical for the prevention of weapon malfunctions and possible injuries to personnel... [Pg.368]

Such techniques imply analysis of chemical products of photolysis. Application of mass-spectrometers of various types is often hampered by a number of circumstances. These difficulties will be discussed later on. The EPR method, which is currently the most extensively employed technique, features low sensitivity and is usually used for analysis of primary fragments of photolysis. For this purpose, the radicals produced are frozen on the walls of a quartz pin and are thus accumulated inside the device. On one hand, this approach allows one to overcome the sensitivity threshold of the device. However, on the other hand, this excludes the possibility of direct kinetic measurements. The SS technique permits the use of weak light sources for detecting active particles under... [Pg.226]

Although following similar nuclear reaction schemes, nuclear analytical methods (NAMs) comprise bulk analysing capability (neutron and photon activation analysis, NAA and PAA, respectively), as well as detection power in near-surface regions of solids (ion-beam analysis, IB A). NAMs aiming at the determination of elements are based on the interaction of nuclear particles with atomic nuclei. They are nuclide specific in most cases. As the electronic shell of the atom does not participate in the principal physical process, the chemical bonding status of the element is of no relevance. The general scheme of a nuclear interaction is ... [Pg.662]

Light-silver-colored element generated from a plutonium isotope (241Pu) by beta decay. Never detected in nature. Chemically similar to Europium. A few tons have been produced throughout the world through regeneration of fuel rods. Americium is a good source of alpha rays. Hence it is suitable to measure thicknesses, as a detector in smoke alarms, and for the activation analysis of the tiniest amounts of substances. [Pg.156]

Highly sensitive determination of "Tc is possible using today s advanced mass spectroscopic methods. However, orthodox determination methods of "Tc involving radiometric techniques or even activation analysis are still used because they are simple and can be done without expensive machines. The detection limits of typical analytical methods are listed in Table 1. [Pg.24]

To date, a few methods have been proposed for direct determination of trace iodide in seawater. The first involved the use of neutron activation analysis (NAA) [86], where iodide in seawater was concentrated by strongly basic anion-exchange column, eluted by sodium nitrate, and precipitated as palladium iodide. The second involved the use of automated electrochemical procedures [90] iodide was electrochemically oxidised to iodine and was concentrated on a carbon wool electrode. After removal of interference ions, the iodine was eluted with ascorbic acid and was determined by a polished Ag3SI electrode. The third method involved the use of cathodic stripping square wave voltammetry [92] (See Sect. 2.16.3). Iodine reacts with mercury in a one-electron process, and the sensitivity is increased remarkably by the addition of Triton X. The three methods have detection limits of 0.7 (250 ml seawater), 0.1 (50 ml), and 0.02 pg/l (10 ml), respectively, and could be applied to almost all the samples. However, NAA is not generally employed. The second electrochemical method uses an automated system but is a special apparatus just for determination of iodide. The first and third methods are time-consuming. [Pg.81]

Various other techniques have been used to determine molybdenum, including adsorption voltammetry [510], electron-paramagnetic resonance spectrometry [512], and neutron activation analysis [513,514]. EPR spectrometry is carried out on the isoamyl alcohol soluble Mo(SCN)s complex and is capable of detecting 0.46 mg/1 molybdenum in seawater. Neutron activation is carried out on the /J-naphlhoin oxime [514] complex and the pyrrolidone dithiocar-bamate and diethyldithiocarbamate complex [513]. The neutron activation analysis method [514] was capable of determining down to 0.32 xg/l of molybdenum in seawater. [Pg.206]

Holzbecker and Ryan [825] determined these elements in seawater by neutron activation analysis after coprecipitation with lead phosphate. Lead phosphate gives no intense activities on irradiation, so it is a suitable matrix for trace metal determinations by neutron activation analysis. Precipitation of lead phosphate also brings down quantitatively the insoluble phosphates of silver (I), cadmium (II), chromium (III), copper (II), manganese (II), thorium (IV), uranium (VI), and zirconium (IV). Detection limits for each of these are given, and thorium and uranium determinations are described in detail. Gamma activity from 204Pb makes a useful internal standard to correct for geometry differences between samples, which for the lowest detection limits are counted close to the detector. [Pg.282]

Lieser et al. [628] studied the application of neutron activation analysis to the determination of trace elements in seawater, with particular reference to the limits of detection and reproducibility obtained for different elements when comparing various preliminary concentration techniques such as adsorption on charcoal, cellulose, and quartz, and complexing agents such as dithizone and sodium diethyldithiocarbamate. [Pg.284]

May et al. [73] used neutron activation analysis to determine 237neptunium in waste waters. The determination used the 237Np(rc,y)238Np reaction. The detection limit was 5 x 10 6 xg of 237neptunium, which corresponds to 2.5 x 10 6 xg/kg for 200 ml seawater samples. [Pg.354]

In Gubbio, Italy, a 1 cm layer of clay between extensive limestone formations marks the boundary between the Cretaceous and Tertiary Periods. This clay layer was known to have been deposited about 65 million years ago when many life forms became extinct, but the length of time associated with the deposition was not known. In an attempt to measure this time with normally deposited meteoritic material as a clock, extensive measurements of iridium abundances (and those of many other elements) were made on the Gubbio rocks. Neutron activation analysis was the principal tool used in these studies. About 50 elements were searched for in materials like the earth s crust, about 40 were detected and about 30 were measured with useful precision [26-28]2. [Pg.397]

This method has not been used so far for olefin polymerisations, but in fact the only difficulty in its application is that Q must be such that it can be detected in the very low concentrations (10 6 to 10"9 M) which x is believed to have in these reactions, for instance by activation analysis. [Pg.423]

Until it was known that the half-life of Tc is much shorter than 10 years Herr looked for technetiimi-98 in a munber of minerals from Norway and South Africa by neutron activation analysis. This most sensitive method was also used by Alperovitch et al. and Anders et al. to detect this isotope in nature. According to the nuclear reaction... [Pg.112]


See other pages where Detection activation analysis is mentioned: [Pg.526]    [Pg.320]    [Pg.244]    [Pg.323]    [Pg.288]    [Pg.671]    [Pg.236]    [Pg.356]    [Pg.355]    [Pg.356]    [Pg.143]    [Pg.91]    [Pg.63]    [Pg.112]    [Pg.207]    [Pg.234]    [Pg.664]    [Pg.666]    [Pg.67]    [Pg.443]    [Pg.24]    [Pg.26]    [Pg.237]    [Pg.5]    [Pg.340]    [Pg.61]    [Pg.200]    [Pg.379]    [Pg.319]   
See also in sourсe #XX -- [ Pg.778 ]




SEARCH



Activation analysis detection limits

Active detection

Detection neutron activation analysis

Neutron activation analysis detection levels

© 2024 chempedia.info