Connectors type

Template defines protocol of actions between components that use this connector type... [Pg.55]

These are examples you can define your own kinds of connectors to meet the needs of your enterprise. Being able to separately and explicitly define connector types lets us further decouple intercomponent dependencies from the component implementations and better abstract the structure of components when they are composed later. [Pg.435]

Big components are made by connecting smaller ones. In this section we explain how the connector types in our example architecture support composition. [Pg.448]

Component (type or instance) Connector Type implied by arrow,... [Pg.475]

Which of the following connector types are not typically associated with mice ... [Pg.892]

The third part, titled specific information, could be quite lengthy, and no specific length limitations should be imposed. In this part, short summaries of information acquired from individual sources should be provided. It is important to write these summaries in such a form that it will be easy later to find major concepts and known realization of these concepts (which will be related to symbolic attributes). The identified concepts will eventually lead us to symbolic attributes, while examples of realizations will provide information about the feasible values of these symbolic attributes. For example, in the case of joints in timber floor trusses, we may identify such concepts as truss joint or joint plate and such examples of realizations as steel joint plate or nails. These concepts may lead to such symbolic attributes as joint type, joint plate material, and connectors type. ... [Pg.149]

The first symbolic attribute, joint type, may have such values as hinged or rigid, and the second attribute may have such values as steel, aluminum, or copper. The third attribute, connectors type, may have such values as nails, adhesive, or no individual connectors. ... [Pg.150]

Fraction of sites with crystallographic folds Fraction of sites with loose folds Length factor for free ends s Length factor for loose folds s Relative probability of connector types ... [Pg.344]

Connector Type DC Test Voltage (kW) Peak Power (kW)... [Pg.316]

FIGURE 9.39 Common fiber optic connector types, (a) FC, (b) SC, (c) ST-compatiable, (d) FDDI, (e) MTRJ, (f) LC-compatible. (Courtesy of Corning Cable Systems LLC and Corning Inc.)... [Pg.933]

The Swiss company, WW Fischer, offers PTFE (Teflon PTFE or Hostaflon), PBT (Celanex, Crastin, Ultradur or Valox) or PEEK (Victrex) insulator material options in its 405 series of cylindrical connectors according to the requirements of working temperature and other criteria. PEEK is an expensive polymer which tends to be employed when other materials fail to meet the specification requirements of the application. Other Fischer connector types use polyamide-imide (Torlon) or POM (Celcon, Delrin or Hostaform). Elastomeric seals used by Fischer in conjunction with their connectors are made from acrylonitrile-butadiene rubber (NBR N BUNA) or to MIL-P-25732, fluoroelastomer (FPM VITON), polychloroprene elastomer (CR Neoprene), ethylene-propylene diene elastomer (EPDM) and styrene-ethylene-butadiene-styrene thermoplastic elastomer (TPE-S or TPE-O) where each compound is followed by its trade name. Fischer s Swiss competitor, Lemo, manufactures a similar range of connectors including the Redel types which have a plastic body. [Pg.34]

PIO generate inteirupts Interrupt priority level PIO port direaion PIO connector type PIO Connector size PIO port drive SIO... [Pg.109]

CONNECTOR-SIZE = 9 pins CONNECTOR-TYPE = MALE ... [Pg.117]

Union Connectors. CoUar and cone-type connectors (Figs. 26a and b) are nearly always used to connect smaU bore tubes at pressures up to about 400 MPa (140). The included angle of the end of the tube is 55—57° and that of the seat 60—61° so that when the gland nut is tightened into the connector a metal-to-metal seal is formed along a narrow band of contact between the end of the tube and the connector. Union connectors for smaU bore tubes at pressures of 500 MPa and above usuaUy employ lens rings. [Pg.94]

Great care is needed in the design of autoclaves and sterilization cycles because of the requirement for the presence of moisture. The autoclave must be loaded to allow complete steam penetration to occur in all parts of the load before timing of the sterilization cycle commences. The time required for complete penetration, the so-called heat-up time, varies with different autoclave constmction and different types of loads and packaging materials. The time may not exceed specific limits in order to guarantee reproducibility and, for porous loads, saturated steam. The volume of each container has a considerable effect on the heatup time whenever fluids are sterilized. Thermocouples led into the chamber through a special connector are often employed to determine heatup times and peak temperatures. The pressure is refleved at the end of each sterilization cycle. Either vented containers must be used or... [Pg.407]

Fig. lab. Some types of electronic connectors, (a) Receptacle for dual-in-line package (DIP) semiconductor integrated circuit, (b) Connectors for printed circuit boards having edge contacts two-piece connectors have male and female connector halves, one of which is attached to the printed circuit board. [Pg.23]

Another type of electronic connector joins coaxial conductors. These have a soHd or stranded center-conductor surrounded by a dielectric. The dielectric is covered with a conductive shield made of metal braid or tape and with a layer of insulation. Coaxial cable connectors terminate the center-conductor and the shield. These are used primarily in radio frequency circuits. The shape, dimensions, and materials of an electronic connector shell or stmcture may have to be designed to shield the connection from electromagnetic and radio frequency interferences in many appHcations. [Pg.26]

Fig. 12. Typical connectors for power distribution cable, (a) Aluminum sleeve barrel for uninsulated cable, (b) Clamp-type terminal connector for insulated... Fig. 12. Typical connectors for power distribution cable, (a) Aluminum sleeve barrel for uninsulated cable, (b) Clamp-type terminal connector for insulated...
Type of Treatment Items Treated Splashers or Spray Nozzles Stairway and Handrail Structural Connectors Ring Joint Connectors Bolts, Nuts, Washers Anchor Connectors Nails Mechanical Equipment Support Anchor Bolts—Material Furnished by Cold Water Basin—Material Furnished by Basin Accessories, by Mfg. ... [Pg.420]

It is good practice to use a different type of connector on each type of service point. [Pg.99]

The hose was fixed to the connector or to the plant by a screwed clip of the type used for automobile hoses (Jubilee clips). These are unsuitable for industrial use. Bolted clamps should be used. [Pg.150]

For lower pressure systems of approximately 150 psig at 400°F or 225 psig at 100°F, and w here sanitary precautions (food products or chemicals used in food products) or some corrosion resistance is necessary, tubing is used. It is joined together by butt welds (Figure 2-8) or special compression or hub-type end connectors. This style of piping is not too common in the... [Pg.59]

Avoid the use of shrink-type tool joints on drillpipes and drill collars (connectors, in this case). Flash-welded tool joints for drillpipes and integral drill-collar joints should be used. [Pg.1340]


See other pages where Connectors type is mentioned: [Pg.73]    [Pg.435]    [Pg.739]    [Pg.67]    [Pg.861]    [Pg.203]    [Pg.119]    [Pg.73]    [Pg.435]    [Pg.739]    [Pg.67]    [Pg.861]    [Pg.203]    [Pg.119]    [Pg.338]    [Pg.327]    [Pg.12]    [Pg.319]    [Pg.526]    [Pg.331]    [Pg.464]    [Pg.303]    [Pg.23]    [Pg.25]    [Pg.27]    [Pg.28]    [Pg.114]    [Pg.138]    [Pg.192]    [Pg.160]    [Pg.226]    [Pg.1166]   
See also in sourсe #XX -- [ Pg.523 , Pg.524 ]