Use the cell-flow technique (32) to determine the inhibition of the receptor. In these experiments, cells containing the uAChR are used. The maximum current amplitude, a measure of the concentration of open receptor-channels, is determined. The experiments are done in the presence of 100 pM carbamoylcholine (a stable analog of acetylcholine) and in the absence and presence of 150 pM cocaine. [Pg.36]

Cell separation techniques that use an inward flow component are referred to as countercurrent separation techniques. The concept of countercurrent separation is compHcated by biological variations of all parameters in equation 4. [Pg.522]

A significant advance in this area was recently made by Li and coworkers [30,31], who developed a laminar flow technique, that allowed the direct contact of two liquids with better-defined mass transport compared to the Lewis cell. Laminar flow of the two phases parallel to the interface was produced through the use of flow deflectors. By forcing flow parallel to, rather than towards, the interface, it was proposed that the interface was less likely to be disrupted. Reactions were followed by sampling changes in bulk solution concentrations. [Pg.336]

As stated earlier, activation of endothelial cells by pro-inflammatory stimuli leads to the expression of cell adhesion molecules and cytokines such as IL-6 and IL-8. The expression and hence modulation of surface expressed adhesion molecules by e.g. targeted delivery of inhibitors of NFkB, can be measured using flow cytometric analysis or whole cell ELISA techniques. Cytokine production can be measured in the supernatant of cultured cells or in biological fluids. Furthermore, competitive or quantitative RT-PCR analysis of mRNA levels of cell adhesion molecules or cytokines, allows the transcriptional activity of the genes of interest to be estimated. [Pg.187]

Isolation of Cells for Transport Studies Use of nonequilibrium thermodynamics in the analysis of transport general flow-force relationships and the linear domain, 171, 397 cell isolation techniques use of enzymes and chelators, 171, 444 cell separation by gradient centrifugation methods, 171, 462 cell separation by elutriation major and minor cell types from complex tissues,... [Pg.450]

While natural heterogeneity of cancer specimens is well documented, and the ability to isolate hundreds to thousands of cells with techniques such as LCM have allowed microarray analysis of more pure populations, the recent re-introduction of the cancer stem cell theory (24,25) has presented an extreme example of the need to isolate rare populations of cells. Cancer stem cells appear to exist at a frequency on the order of 1 in 1000 cells (26). While obtaining completely pure populations of stem cells remains difficult, highly enriched populations of these cells can be isolated using flow cytometry separating on the basis of the presence of certain specific cell markers. [Pg.6]

Calibration and quantification procedures are easier in LA-ICP-MS compared to other solid-state mass spectrometric techniques because the laser ablation and the ICP ion source operate at normal pressure and the laser ablation of solid samples and ionization of analytes are separated in space and time. Therefore the advantage of solution calibration in ICP-MS can be applied in this solid-state analytical technique. The introduction of solution based calibration, which is only possible in LA-ICP-MS, was an innovative step in the development of this sensitive mass spectrometric technique. A number of different calibration approaches using aqueous standard solutions in the dual gas flow technique have been discussed by various authors.74 75 In the dual gas flow injection technique , the nebulized standard solution and the laser ablated sample material are mixed in the -piece and the two gas flows from the nebulizer (e.g. ultrasonic nebulizer) and laser ablation chamber are added. Using solution based calibration with the addition of a standard solution, Leach et alP determined minor elements in steel reference materials with a relative accuracy of a few %. In comparison to the so-called dual gas flow technique proposed in the literature, where the argon flow rates through the nebulizer and ablation cell add up to 11 min-1 (e.g. 0.451 min-1 and... [Pg.201]

Randle, K., and Hartmann, E. H. (1987). Applications of the continuous flow stirred cell (CFSC) technique to adsorption of zinc, cadmium and mercury on humic acids, Geoderma 40, 281-296. [Pg.202]

Flow and Circulation Cells. Voltammetric techniques can be used to monitor a flowing stream continuously for example, the effluent from an ion exchange column. Of course, the material whose detection is sought must be electroactive. An effective cell design has been described (Figure 6.20) that employs a vertical-orifice dropping mercury electrode.65 The cell possesses a low holdup time, a small volume, and a low flushout time, all of which ensure rapid... [Pg.283]

For compounds that nitrate rapidly at room temperature, two methods may be used. The substrate may be dissolved in sulfuric acid of appropriate strength and introduced into one limb of a two-limbed flask. A solution of nitric acid in sulfuric acid is introduced into the other limb, the flask is thermostatted, and the reaction started by vigorously shaking the flask. Aliquots are then withdrawn and quenched as before. However, by far the most convenient method is to carry out the kinetics directly in the thermostatted spectrophotometric cell and this would now be the method of choice in view of the automatic monitoring facilities currently available on spectrophotometers. For very fast reactions, stopped-flow techniques have been used. [Pg.44]

The ESR method combined with a flow system should be very powerful for studying short lived transient radicals during vinyl polymerization in solutions. As will be made clear later, however, the conditions for the reaction occurring in the flow cell are quite different from the conventional solution polymerization studied during a steady-state process. Nevertheless, the hyperfine structure of the ESR spectra observed by the flow technique, can provide straightforward information on the structure, concentration, reactivity, and even the steric conformation of the transient radicals involved, particularly at the initial stage of the polymerization. [Pg.143]

Researchers should be familiar with basic sterile cell culture techniques, the ability to grow, passage, and plate cells. All work is conducted in a laminar flow biosafety cabinet using sterilized reagents and equipment. [Pg.56]

Microfiltration. Microfiltration, the use of tangential flow anisotropic membranes to permeate the product of choice while retaining solids, can be an attractive cell separation technique because it does not require the use of flocculants or filter aids. It is, in principle, a more technically sophisticated version of classic dead-end filtration processes. Microfiltration yields can be low due to progressive fouling of membranes. Advanced engineering has overcome many of the early... [Pg.1332]

If one of the species is predominantly hydrated (e.g. the quinazoline cation ), then, by using the rapid-reaction apparatus and allowing an acid solution of the substance and a near-neutral buffer to run through the cell continuously [continuous-flow technique ), the spectrum of the predominantly hydrated (unstable) neutral species can be obtained. This is possible if the newly formed species is not too unstable. [Pg.15]

Because stopped-flow techniques are widely used with optical detection, samples should be prepared in solution and produce detectable signal changes after mixing into the cell. In some situations, if the reaction of some samples is very rapid and complete within the dead time of the stopped-flow instruments, the majority and indeed the entire kinetic time course may be lost. Selected adjustment of concentration, solution conditions, temperature, and so on, may be able to slow the reaction into an accessible time range, but this is not always possible or desirable. Such systems are not amenable to the stopped-flow technique. In general, other techniques will have to be used, and these will be... [Pg.6313]

Scenario RayRay s House of Hair is a new chain of beauty salons that aims to reduce customer wait and servicing time. Let s see how RayRay uses the Work Cell Design technique to optimize the flow of the hair-cutting process. [Pg.296]


See other pages where Cell-flow technique is mentioned: [Pg.21]    [Pg.21]    [Pg.338]    [Pg.591]    [Pg.805]    [Pg.453]    [Pg.143]    [Pg.818]    [Pg.39]    [Pg.395]    [Pg.182]    [Pg.324]    [Pg.332]    [Pg.87]    [Pg.261]    [Pg.36]    [Pg.111]    [Pg.127]    [Pg.198]    [Pg.509]    [Pg.182]    [Pg.324]    [Pg.332]    [Pg.145]    [Pg.268]    [Pg.442]    [Pg.74]    [Pg.250]    [Pg.285]    [Pg.431]    [Pg.201]    [Pg.139]    [Pg.197]   