Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Detection optical

Optical detection of the Rydberg atoms is a very attractive technique simply because the dominant fluorescence for two states that are nearly degenerate ( 1 cm apart) can be red for one state and blue for the other. Consequently it is a straightforward matter to distinguish between two states, and optical detection has been used successfully with several alkali atoms, Li, Na, and A typical experiment is the study of the Cs [Pg.143]

There are certain limitations to this technique that are worth noting. First, if the rf is on continuously, the size of the resonance signal S, the fraction of atoms that decay detectably from the final state, is related to the decay rates of the two states by [Pg.143]

Absorbance. The detection of substrate depletion or product accumulation through the measurement of visible or UV fight absorbance is based on the Beer-Lambert law, which directly relates absorbance at a given wavelength to concentration  [Pg.47]

Serum alkaline phosphatase, which is an important metabolic indicator, is generally quantitated by absorbance methods. Alkaline phosphatase catalyzes the dephosphorylation of NADP+ and a variety of other substrates in vivo, but in vitro, the synthetic substrate / -nitrophenyIphosphate (Eq. 3.20) can be used. [Pg.48]

The product, nitrophenol, absorbs at 405 nm10 with s = 1.85 x 104M-1cm-1. When a diluted semm sample is subjected to saturating concentrations of p-nitro-phenylphosphate, and incubated at room temperature for 15 min, and absorbance [Pg.48]

A cascade amplification method has been proposed for improving the detection limit of the alkaline phosphatase assay, and involves a different synthetic substrate (Eq. 3.21), (oxotrifluorobutyl)phenylphosphate 11 [Pg.49]

When this substrate is dephosphorylated, its product acts as an inhibitor of a second enzyme, rabbit liver esterase. Thus, as alkaline phosphatase activity increases, there is a corresponding increase in the concentration of inhibitor produced, and consequently a decrease in the activity of the esterase. A second synthetic substrate was prepared for the (relatively nonselective) esterase, so that the indicator reaction is as shown in Eq. 3.22 below  [Pg.49]


D. Royer and E. Dieulesaint, Optical detection of sub-angstrom transient mechanical displacements , IEEE Ultrasonics Symposium Proceedings, 1986. [Pg.699]

Ribbe A E 1997 Laser scanning confocal microscopy in polymer science Trends Polym. Sc/. 5 333-7 Oliveira M J and Hemsiey D A 1996 Optical microscopy of polymers Sonderb. Prakt. Metallogr. 27 13-22 Nie Sh and Zare R N 1997 Optical detection of single molecules Ann. Rev. Biophys. Biomol. Struct. 26 567-96 Masters B R 1994 Confocal redox imaging of cells Adv. Mol. Cell Biol. 8 1-19... [Pg.1675]

To measure friction and shear response, one has to laterally drive one surface and simultaneously measure the response of a lateral spring mount. A variety of versions have been devised. Lateral drives are often based on piezoelectric or bimorph deflection [13, 71] or DC motor drives, whereas the response can be measured via strain gauges, bimorphs, capacitive or optical detection. [Pg.1738]

The first half of this section discusses the use of the crossed beams method for the study of reactive scattering, while the second half describes the application of laser-based spectroscopic metliods, including laser-mduced fluorescence and several other laser-based optical detection teclmiques. Furtlier discussion of both non-optical and optical methods for the study of chemical reaction dynamics can be found in articles by Lee [8] and Dagdigian [9]. [Pg.2061]

Laser photolysis of a precursor may also be used to generate a reagent. In a crossed-beam study of the D + FI2 reaction [24], a hypertliennal beam of deuterium atoms (0.5 to 1 eV translational energy) was prepared by 248 mn photolysis of DI. This preparation method has been widely used for the preparation of molecular free radicals, both in beams and in experiments in a cell, with laser detection of the products. Laser photolysis as a method to prepare reagents in experiments in which the products are optically detected is fiirtlier discussed below. [Pg.2066]

Skinner J L 1997 Theoretical models for the spectral dynamics of individual molecules in solids Single Molecule Optical Detection, Imaging and Spectroscopy ed T Basche, W E Moerner, M Orrit and U P Wild (Weinheim VCFI)... [Pg.2507]

Knoche W and Wiese G 1976 Pressure-jump relaxation techniques with optical detection Rev. Sc/. Instrum.47 220-1... [Pg.2969]

Quednau J and Schneider G M 1989 A new high-pressure cell for differential pressure-jump experiments using optical detection Rev. Sc/. Instnim. 60 3685-7... [Pg.2969]

Finished zinc and zinc aHoys are usuaHy analyzed for metals other than zinc by emission spectroscopy and the zinc determined by difference. ASTM method E 27 describes a technique using a dissolved sample and photographic detection. The internal standard is the zinc line at 267.0 nm. However, procedures using soHd samples are generaHy preferred and photoelectric detection often replaces optical detection. Samples are cast and machined on the surface where the arc is stmck. Up to 15 elements can be determined in a few minutes by modem automatic spectrometers. ASTM gives wet chemical methods for metals other than zinc (79). [Pg.410]

In some systems, known as continuous-flow analy2ers, the reaction develops as the sample —reagent mixture flows through a conduit held at constant temperature. In such systems, the reaction cuvettes are replaced by optical reading stations called flow cells. In most analy2ers, whether of discrete- or continuous-flow type, deterrnination of electrolyte tests, eg, sodium and potassium levels, is done by a separate unit using the technique of ion-selective electrodes (ISE) rather than optical detection. [Pg.392]

Fig. 3. Schematic of optical detection methods, (a) absorbance or colorimetric (b) turbidimetric and (c) nephelometric. Fig. 3. Schematic of optical detection methods, (a) absorbance or colorimetric (b) turbidimetric and (c) nephelometric.
Although the presence of condensate can be detected electrically, the original and most often used method is the optical detection of... [Pg.765]

Explosion Suppression With explosion suppression, an incipient explosion is detected and—within a few milhseconds—a suppressant is discharged into the exploding medium to stop combustion. Pressure and optical detection systems are used suppressors are pressurized and release the suppressants when actuated by an electroexplosive device. [Pg.2318]

Monitor exterior wall temperature with infrared optical detection system, and operating instructions for operator response if high temperature signal occurs... [Pg.58]

For IBSCA analysis, standard HV or, better, UHV-equipment with turbomolecular pump and a residual gas pressure of less than 10 Pa is necessary. As is apparent from Fig. 4.46, the optical detection system, which consists of transfer optics, a spectrometer, and a lateral-sensitive detector, is often combined with a quadrupole mass spectrometer for analysis of secondary sputtered particles (ions or post-ionized neutrals). [Pg.242]

Optical detection of magnetic resonance (ODMR) was attempted for measurements of the pH effects on the triplet state of purine to investigate the protonation site of purine at low temperatures (78JA7131). The ODMR spectrum did not show the presence of more than one triplet state at liquid helium temperatures. Since the protonated tautomers 1H,9H (3a) and H,1H (3b) have similar bond structures, their triplets should have similar zero-field parameters and are thus not easy to distinguish by ODMR. [Pg.54]

Optically detected magnetic resonance (ODMR) has yielded valuable information about dynamics of long-lived pholoexcitations of conjugated polymers. The technique relies upon the paramagnetic interaction of excitations with an applied magnetic field. For a particle with non-zero spin, placed in a magnetic field, the Hamiltonian is ... [Pg.424]

The reactants are then mixed in various proportions, and the sedimentation ratio (scompiex/smucin)—the ratio of the sedimentation coefficient of the complex to that of the pure mucin itself—is used as the measure for mucoad-hesion. The ultra-violet absorption optics on the XL-A or XL-1 ultracentrifuge have been used as the main optical detection system. Although the polysaccharide is generally invisible in the near UV ( 280 nm), at the concentrations normally employed the mucin—in uncomplexed and complexed form—is detectable. [Pg.244]

Glasbeek M (2001) Excited State Spectroscopy and Excited State Dynamics of Rh(III) and Pd(II) Chelates as Studied by Optically Detected Magnetic Resonance Techniques. 213 95-142 Glass RS (1999) Sulfur Radical Cations. 205 1-87 Gobbi L, see Diederich F (1999) 201 43-129... [Pg.233]


See other pages where Detection optical is mentioned: [Pg.1063]    [Pg.2071]    [Pg.2081]    [Pg.2483]    [Pg.2497]    [Pg.2871]    [Pg.3039]    [Pg.274]    [Pg.513]    [Pg.391]    [Pg.392]    [Pg.396]    [Pg.397]    [Pg.531]    [Pg.245]    [Pg.198]    [Pg.286]    [Pg.12]    [Pg.110]    [Pg.131]    [Pg.230]    [Pg.422]    [Pg.424]    [Pg.585]    [Pg.93]    [Pg.314]    [Pg.16]   
See also in sourсe #XX -- [ Pg.141 , Pg.145 ]

See also in sourсe #XX -- [ Pg.271 ]

See also in sourсe #XX -- [ Pg.89 ]

See also in sourсe #XX -- [ Pg.416 ]

See also in sourсe #XX -- [ Pg.533 , Pg.539 ]

See also in sourсe #XX -- [ Pg.120 , Pg.171 , Pg.195 ]

See also in sourсe #XX -- [ Pg.97 , Pg.103 ]

See also in sourсe #XX -- [ Pg.38 ]

See also in sourсe #XX -- [ Pg.416 ]

See also in sourсe #XX -- [ Pg.228 ]




SEARCH



A Optical Detection of Blood Gases

Absorbance optical detection systems

Atomic force microscopy optical detection mechanism

Atomic optical spectrometry detection limits

Biosensors with optical detection

Breast cancer detection, optical

Chemiluminescence optical detection systems

Confocal optical detection channel

Detecting The Optical Signature

Detection limits atomic optical

Detection mechanism optical devices

Detection optical absorbance

ENDOR optically detected

Electrochemiluminescence optical detection systems

Enzyme-Based Biosensors With Optical Detection

Enzyme-based biosensor with optical detection

Field Optical Microscope Designs for Plasmon Resonant Particle (PRP) Detection

Fluorescence detection integrated optics

Fluorescent detection, instrument optical filter

Glucose, optical detection

Inductively coupled plasma optical emission detection limits

Limits of optical detection

Mesophase optical texture detected

ODMR (optically detected magnetic

On-Chip Detection Using Optical Fibers

On-Chip Micro-optical Detection

Optical Absorption Detection

Optical Detection of Coherent Phonons

Optical Detection of Transients

Optical Detection on Centrifugal Microfluidic

Optical Filters for Head-On Fluorescence Detection

Optical Single-Molecule Detection at Room Temperature (Meixner)

Optical absorbance detection limits

Optical absorbance detection limits improving

Optical activity detecting

Optical activity detection

Optical arrangements, for single molecule detection

Optical detected ESR

Optical detection devices

Optical detection methods

Optical detection of liquid-state NMR

Optical detection of magnetic resonance

Optical detection of magnetic resonance ODMR)

Optical detection of neutral molecules

Optical detection protocol

Optical detection sensitivity

Optical detection systems

Optical detection systems Raman spectroscopy

Optical detection systems detector cell types used

Optical detection systems laser-induced fluorescence

Optical detection systems surface plasmon resonance

Optical detection, use

Optical heterodyne detection

Optical multichannel detection

Optical rotation detection

Optical-based detections, amplification

Optically detected magnetic

Optically detected magnetic resonance

Optically detected magnetic resonance ODMR)

Optically detected magnetic resonance ODMR) studies

Optically detected magnetic resonance absorbance

Optically detected magnetic resonance apparatus

Optically detected magnetic resonance complexes

Optically detected magnetic resonance fluorescence

Optically detected magnetic resonance instrumentation

Optically detected magnetic resonance line widths

Optically detected magnetic resonance phosphorescence

Optically detected magnetic resonance sensitivity

Optically detected magnetic resonance spectra

Optically detected magnetic resonance tryptophan

Optically detected magnetic resonance zero-field splitting

Picosecond spectroscopy optical detection

Porphyrins optical detection

Principle of Optically Detected Magnetic Resonance

Pulse optical detection

Radical pair optical absorption detection

Reagentless detection, optical

Refractive index optical detection systems

Refractive optical detection method

Thermo-optical absorbance detection

Viscosity measurement optical detection

Zero-Field Optically Detected Magnetic Resonance (ODMR)

© 2024 chempedia.info