Dabsyl Chloride (4-dimethyl-aminoazobenzene-4-sulfonyl chloride) Aabs = 420 nm. Derivatives are very stable (days) and can be formed from both primary and secondary amino acids. Detection is by absorption only. Detection limits are in the high picomole range. Reaction time is typically around 10 minutes at 70°C. Completeness of reaction can be adversely affected by the presence of high levels of various salts. Because reaction efficiency is highly matrix dependent and variable for different amino acids, standard amino acid solution should be derivatized under similar conditions/matrix for accurate calibration. Commercial systems available uti-... [Pg.81]

Recently, pure compounds which have molecular weights of the same order as commercial Novolacs have been prepared ° and used to calibrate GPC systems and to study the chemical reaction, for example, with HMTA. [Pg.1637]

Jansen, R., G. Schumann, H. Baadenhuijsen, P. Franck, C. Franzini, R. Kruse, A. Kuypers, C. Weykamp, and M. Panteghini. 2006. Trueness verification and traceability assessment results from commercial systems for measurement of six enzyme activities in serum. An international study in the EC4 framework of the Calibration 2000 project. Clinica ChimicaActa 368 160-167. [Pg.34]

SFA lends itself to continuous operation, and most methods can be run with a continuous flow of sample, rather than coimected to sample changen More than 100 papers specifically concerning online applications of SFA have been published. Modified laboratory systems have been less successful than those specially designed for continuous use, largely due to limited pump tube life and difficulties associated with calibration and sample introduction. In many online applications a response time of 10-15 min is adequate, and so the benefits of gas segmentation in limiting dispersion are questionable. As a result, many of the most successful commercial systems operate without air bubbles. The division between some of these systems and FIA systems is not sharply defined. [Pg.4337]

The spectra are processed by computer software that now often includes advanced chemomet-ric methods (see the discussion of chemometrics in Section 4.7.2.1). Methods such as partial least squares (PLS) and principal component analysis are used by instrument software to construct calibration curves and provide quantitative analysis. LIBS software on many commercial systems supports library matching, sample classification, qualitative, semiquantitative and quantitative analysis including preloaded libraries and calibrations, and customer-built libraries and calibrations. [Pg.577]

After a calibration procedure, for example gazing at the four comers of the display, the eye-tracker can deliver screen coordinates to the computer. The method requires that the head stays in the same position. Consequently, such systems need a head fixation or at least a chin rest, but this is no problem for the disabled person who can t move anything except the eyes. A typical commercial system of such an eye-tracker is the ERICA system, which we used for our research. [Pg.476]

The software life cycle activities extend until retirement of the software. However, in a manner of speaking, life cycle activities extend even beyond retirement since the data must be able to be reconstructed at any time during the life of the product, i.e., the archived record must always be accessible and readable even if the software is no longer commercially available or typically employed in the laboratory. Additional software validation includes implementation of the code and integration and performance testing. There also must be system security, change control procedures, audit trails, calibration, preventative maintenance, and quality assurance. [Pg.1028]

For standard or proprietary polymer additive blends there is the need for analytical certification of the components. Blend technology has been developed for two- to six-component polymer additive blend systems, with certified analytical results [81]. Finally, there exist physical collections of reference additive samples, both public [82] and proprietary. The Dutch Food Inspection Service reference collection comprises 100 of the most important additives used in food contact plastics [83-85]. Reference compounds of a broad range of additives used in commercial plastics and rubber formulations are generally also available from the major additive manufacturers. These additive samples can be used as reference or calibration standards for chromatographic or spectroscopic analysis. DSM Plastics Reference Collection of Additives comprises over 1400 samples. [Pg.18]

In principle, any type of sample can be analysed by SEC provided that it can be solubilised and that there are no enthalpic interactions between sample and packing material. By definition then, this technique cannot be carried out on vulcanisates and even unvulcanised fully compounded rubber samples can present problems due to filler-rubber interactions. The primary use of SEC is to determine the whole MWD of polymers and the various averages (number, viscosity, weight, z-average) based on a calibration curve and to allow qualitative comparisons of different samples. Many commercial polymers have a broad MWD leading to strong peak overlap in the chromatography of complex multicomponent systems. [Pg.261]

The dilatometer is generally made of glass and is the vessel where the mercury is intruded into the sample pores. The design is dependent on the pressure source and monitoring system of the instrument. The dilatometer consists of a sample holder and a calibrated stem, which is used to measure the amount of mercury intruded into the sample. The sample in the dilatometer must be cleaned from adsorbed species by degassing the material in a vacuum [42], Most commercial instruments degas the sample in the instrument before mercury intrusion. Once the sample is degassed, the dilatometer (sample holder and stem) are filled with mercury. [Pg.267]


See other pages where Calibration commercial systems is mentioned: [Pg.534]    [Pg.372]    [Pg.513]    [Pg.272]    [Pg.82]    [Pg.415]    [Pg.361]    [Pg.513]    [Pg.36]    [Pg.674]    [Pg.41]    [Pg.764]    [Pg.489]    [Pg.573]    [Pg.1146]    [Pg.546]    [Pg.64]    [Pg.65]    [Pg.524]    [Pg.38]    [Pg.501]    [Pg.738]    [Pg.33]    [Pg.589]    [Pg.403]    [Pg.556]    [Pg.28]    [Pg.486]    [Pg.438]    [Pg.256]    [Pg.184]    [Pg.260]    [Pg.452]    [Pg.40]    [Pg.164]    [Pg.57]    [Pg.306]    [Pg.128]   