Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pump limit

All Curves for 100% Speed Pumping Limit-min. Setting -and Reduced Speed... [Pg.515]

Pump Limitations. Table 4-116 shows there are six possible liner sizes that can be used on the Model E-700 mud pump. Each liner size must be considered to obtain the optimum circulation flowrate and appropriate liner size. The maximum pressure available for each liner size will be reduced by a safety factor of 0.90. The maximum volumetric flowrate available for each liner size will also be reduced by a volumetric efficiency factor of 0.80 and an additional safety factor of 0.90. Thus, from Table 4-116, the allowable maximum pressures and allowable maximum volumetric flowrates will be those shown in Figures 4-207 through 4-212, which are the liner sizes 5j-, 6, 6-[, 6- and 7 in., respectively. Plotted on each of these figures are the total pressure losses for the various circulation flowrates considered. The horizontal straight line on each figure is... [Pg.893]

Impeller limit. This was the subject of Chap. 23. Sometimes this is called a pump limit. [Pg.317]

Tanford, C. (1982b). Steady state of an ATP-driven calcium pump Limitations on kinetic and thermodynamic parameters. Proc. Natl. Acad. Sci. USA 79,6161-6165. [Pg.65]

However, one disadvantage associated with the use of most recombinant molecules is their rapid clearance. Because of this rapid clearance, recombinant molecules require repeated administration to achieve biological efficacy. Initially, continuous infusion was used to address this pharmacological deficiency. Continuous infusion has the advantage of delivering drugs in a controlled manner and is particularly appropriate when it is important to maintain constant plasma drug concentrations. However, the requirement for continuous venous access and the use of ambulatory pumps limits its use. [Pg.4]

For a direct material balance, the inlet liquid is flow controlled, the level is maintained by adjusting the steam flow and the pressure is then controlled by adjusting the vapor flow, as shown in Figure 3.13(B). If the feed pump limits capacity, the pressure should be allowed to droop by putting the controller into manual with a fully open valve. Then the feed flow controller will run with its valve fully open and the pressure will droop to an equilibrium point, where inlet flow equals the flow through the downstream equipment. [Pg.47]

Two hospital wastes are received and stored in separate tanks at an incineration facility. The first, a sludge with an net heating value (NHV) of 6000Btu/lb contains 2% Cd by weight. The second, a mercury-contaminated waste with an NHV of 8000Btu/lb, contains 8% Cd by weight. A minimum of lOOOlb/h of each waste is to be incinerated. Because of pump limitations, no more than 5000 Ib/h of each waste can be utilized. [Pg.525]

Likewise, process machinery shall also be examined for materials of construction, in-built safety features such as internal safety valves (e.g. gear pumps), limit switches for overload, over hoisting for hoists, tripping of drive motor in case of jamming of lobes of twin lobe blowers due to dust, etc. [Pg.95]

LOF 6 pumps limit consequences of a single pump failure Pump inertia coupled w ith moderator temperature coefficient cause shut down w ithout DNBR... [Pg.429]

Patient and muring satisfaction is high with fentanyl ITS. Patients find the system convenient with no bulky pump limiting their movement and rehabihtation efforts. This is especially important after major orthopedic surgery. With respect to ease of care (EOC), patients following total joint replacement reported significantly better overall EOC compared to IV-PCA morphine (43 vs. 27% P < 0.001) and better move-... [Pg.457]

In the fusion devices (tokamaks) using carbonaceous plasma facing components (PFC), erosion as well as re-deposition of carbon atoms have been observed. In the current configuration of Tore Supra (TS), the tokamak located in Cadarache, France, the largest part of PFCs is the toroidal pumped limiter, which is in close interaction with the plasma. It is composed of actively cooled (120°C) carbon fiber composites (CFC) tiles. Analysis of long plasma discharges has pointed out an abnormal deuterium retention which can be due to redeposited layers, as observed on several places on the PFCs [1]. These carbon layers (up to 800 micrometers thick) have been collected and their chemical analysis performed using nuclear reaction analysis shows a D/C deuterium concentration less than 10 % [2]. This low co-deposition rate makes difficult explanation of the particle retention and it is possible that porosity and structural properties of deposits play an important role in deuterimn retention. [Pg.249]

The TS samples were scraped-off layers fijom reactor walls collected on the toroidal pumped limiter (LIM sample) and on the leading edge of the neutralizers of pumped limiter (NTR sample). [Pg.249]

By an appropriate extension of the Hamiltonian (9.4), the two-pulse EOM-PMA can be applied to a general electronic AMevel system beyond the weak-pump limit. The method can thus be used, for example, for the calculation of so-called control kernels (see, e.g., ref. 28) within optimal control theory. [Pg.459]


See other pages where Pump limit is mentioned: [Pg.939]    [Pg.515]    [Pg.515]    [Pg.515]    [Pg.875]    [Pg.144]    [Pg.260]    [Pg.288]    [Pg.377]    [Pg.303]    [Pg.141]    [Pg.65]    [Pg.216]    [Pg.135]    [Pg.166]    [Pg.291]    [Pg.293]    [Pg.829]    [Pg.455]    [Pg.748]    [Pg.103]   
See also in sourсe #XX -- [ Pg.373 ]




SEARCH



© 2024 chempedia.info