Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Atmospheric pressure chemical technique

One of the first successful techniques for selectively removing solvent from a solution without losing the dissolved solute was to add the solution dropwise to a moving continuous belt. The drops of solution on the belt were heated sufficiently to evaporate the solvent, and the residual solute on the belt was carried into a normal El (electron ionization) or Cl (chemical ionization) ion source, where it was heated more strongly so that it in turn volatilized and could be ionized. However, the moving-belt system had some mechanical problems and could be temperamental. The more recent, less-mechanical inlets such as electrospray have displaced it. The electrospray inlet should be compared with the atmospheric-pressure chemical ionization (APCI) inlet, which is described in Chapter 9. [Pg.55]

Thus, either the emitted light or the ions formed can be used to examine samples. For example, the mass spectrometric ionization technique of atmospheric-pressure chemical ionization (APCI) utilizes a corona discharge to enhance the number of ions formed. Carbon arc discharges have been used to generate ions of otherwise analytically intractable inorganic substances, with the ions being examined by mass spectrometry. [Pg.388]

Samples containing mixtures of peptides can be analyzed directly by electrospray. Alternatively, the peptides can be separated and analyzed by LC/MS coupling techniques such as electrospray or atmospheric pressure chemical ionization (APCI). [Pg.417]

A number of analytical techniques such as FTIR spectroscopy,65-66 13C NMR,67,68 solid-state 13 C NMR,69 GPC or size exclusion chromatography (SEC),67-72 HPLC,73 mass spectrometric analysis,74 differential scanning calorimetry (DSC),67 75 76 and dynamic mechanical analysis (DMA)77 78 have been utilized to characterize resole syntheses and crosslinking reactions. Packed-column supercritical fluid chromatography with a negative-ion atmospheric pressure chemical ionization mass spectrometric detector has also been used to separate and characterize resoles resins.79 This section provides some examples of how these techniques are used in practical applications. [Pg.407]

Cl is not the only ionization technique where this aspect of interpretation must be considered carefully fast-atom bombardment, thermospray, electrospray and atmospheric-pressure chemical ionization, described below in Sections 3.2.3, 4.6, 4.7 and 4.8, respectively, all produce adducts in the molecular ion region of their spectra. [Pg.54]

Atmospheric-pressure chemical ionization (APCI) is another of the techniques in which the stream of liquid emerging from an HPLC column is dispersed into small droplets, in this case by the combination of heat and a nebulizing gas, as shown in Figure 4.21. As such, APCI shares many common features with ESI and thermospray which have been discussed previously. The differences between the techniques are the methods used for droplet generation and the mechanism of subsequent ion formation. These differences affect the analytical capabilities, in particular the range of polarity of analyte which may be ionized and the liquid flow rates that may be accommodated. [Pg.180]

Particular emphasis has been placed upon electrospray and atmospheric-pressure chemical ionization (APCI) which, in addition to being the currently most widely used interfaces, are ionization techniques in their own right. [Pg.184]

Atmospheric-pressure chemical ionization (APCI) and electrospray ionization are both soft ionization techniques which give rise, almost exclusively, to the production of molecular species. Structural information. [Pg.205]

Up to the present, a number of conventional film preparation methods like PVD, CVD, electro-chemical deposition, etc., have been reported to be used in synthesis of CNx films. Muhl et al. [57] reviewed the works performed worldwide, before the year 1998, on the methods and results of preparing carbon nitride hlms. They divided the preparation techniques into several sections including atmospheric-pressure chemical processes, ion-beam deposition, laser techniques, chemical vapor deposition, and reactive sputtering [57]. The methods used in succeeding research work basically did not... [Pg.152]

The most recent progress in MS analysis of chlorophylls has been obtained with the development of atmospheric ionization methods such as atmospheric pressure chemical ionization (APCl) and electrospray ionization (ESI). These techniques have demonstrated much more sensitivity than thermospray ionization, detecting chloro-... [Pg.438]

A range of MS ionisation techniques are available. Atmospheric pressure chemical ionisation (APCI) and electrospray ionisation (ESI) are becoming the methods of choice for the analysis of low molecular weight additives of mass/ charge (m/z) ratio <3,000. [Pg.570]

The most important techniques belonging to this class are electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and, more recently, atmospheric pressure photoionization (APPI). At present the latter does not have applications in cultural heritage, so it will be not described here. [Pg.49]

McLoughlin, D.A., Olah, T.V., and Gilbert, J.D. 1997. A direct technique for the simultaneous determination of 10 drug candidates in plasma by liquid chromatography/atmospheric pressure chemical ionization mass spectrometry interfaced to a Prospekt solid-phase extraction system. J. Pharm. Biomed. Anal. 15 1893. [Pg.243]

Atmospheric pressure chemical ionization [17] shares many of the attributes of classical CL The technique has gained great popularity in recent years as one of the simple and rugged techniques for coupling... [Pg.334]

Thomas etal. [72] used pyrolysis gas chromatography-mass spectrometry as a fast economic screening technique for polyaromatic hydrocarbons. Thomas used reverse-phase liquid chromatography with atmospheric pressure chemical ionization mass spectrometry/mass spectrometry for the determination of polycyclic aromatic sulphur heterocycles in sediments. [Pg.135]

In off-line coupling of LC and MS for the analysis of surfactants in water samples, the suitability of desorption techniques such as Fast Atom Bombardment (FAB) and Desorption Chemical Ionisation was well established early on. In rapid succession, new interfaces like Atmospheric Pressure Chemical Ionisation (APCI) and Electrospray Ionisation (ESI) were applied successfully to solve a large number of analytical problems with these substance classes. In order to perform structure analysis on the metabolites and to improve sensitivity for the detection of the various surfactants and their metabolites in the environment, the use of various MS-MS techniques has also proven very useful, if not necessary, and in some cases even high-resolution MS is required. [Pg.25]

These problems have largely been solved by the development of a wide variety of powerful LC-MS interfaces (reviewed in Refs. [1-3]). In the following paragraphs, the two most widely used atmospheric pressure ionisation (API) systems, namely atmospheric pressure chemical ionisation (APCI) and electrospray ionisation (ESI), are briefly described, along with the older technique of thermospray ionisation... [Pg.144]

Several years later, the next step in the application of MS-MS for mixture analysis was developed by Hunt et al. [3-5] who described a master scheme for the direct analysis of organic compounds in environmental samples using soft chemical ionisation (Cl) to perform product, parent and neutral loss MS-MS experiments for identification [6,7]. The breakthrough in LC-MS was the development of soft ionisation techniques, e.g. desorption ionisation (continuous flow-fast atom bombardment (CF-FAB), secondary ion mass spectrometry (SIMS) or laser desorption (LD)), and nebulisation ionisation techniques such as thermospray ionisation (TSI), and atmospheric pressure ionisation (API) techniques such as atmospheric pressure chemical ionisation (APCI), and electrospray ionisation (ESI). [Pg.152]

Puig et al. [450] determined ng/1 levels of priority methyl-, nitro-, and chloro-phenols in river water samples by an automated on-line SPE technique, followed by liquid chromatography-mass spectrometry (LC-MS) using atmospheric pressure chemical ionization (APCI) and ion spray interfaces. [Pg.62]

Other combinations of chromatography techniques with MS which may be useful in environmental studies are the coupling of high performance liquid chromatography (LC) with MS [84,384,504,506,530,585-593],LC with MS-MS [181, 594 - 599], LC with atmospheric pressure chemical ionization MS (LC-APCI-MS) [600], and Fourier transform infrared spectroscopy-fast atom bombardment coupled to LC-MS (FTIR-FAB-LC-MS) [514]. [Pg.79]

With the development of sophisticated ionization techniques including electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), HPLC-MS techniques have been successfully applied to the online analysis of ginsenosides in extracts and biological fluids (Fuzzati, 2004). In terms of sensitivity and specificity, an MS detector is better than UV or ELSD. Among the various MS methods, the HPLC-MS-MS (or just LC-MS-MS) technique is to date the most sensitive method for detection and quantification of ginsenosides. [Pg.57]


See other pages where Atmospheric pressure chemical technique is mentioned: [Pg.71]    [Pg.142]    [Pg.246]    [Pg.468]    [Pg.345]    [Pg.314]    [Pg.426]    [Pg.830]    [Pg.378]    [Pg.544]    [Pg.26]    [Pg.142]    [Pg.22]    [Pg.63]    [Pg.329]    [Pg.375]    [Pg.658]    [Pg.84]    [Pg.189]    [Pg.49]   


SEARCH



Atmospheric pressure chemical

Atmospheric pressure chemical separation techniques

Atmospheric-pressure chemical ionization techniques

Chemical pressure

Chemical techniques

Technique pressures

© 2024 chempedia.info