Analyzers chromatography

To find explosives Gas analyzers, chromatography instruments, drift-spectrometers, neutron defectosopes, nuclear-magnetic and nuclear-quadrupole resonant instruments... [Pg.912]

Isoenzymes. Multiple forms of citrus PE were reported by Evans and McHale (AO) and Versteeg et al. (Al). PE was purified from West Indian limes and Navel oranges by fractionation of the whole fruit extracts with (NH. SO (AO-65%), adsorption and elution from Sephadex G-75 columns (AO). The PE active fractions were combined and concentrated before separation into two active PEs on the basis of their elution volume from a DEAE Sephadex A-50 column. Orange PEI (OPEI) and lime PEI (LPEI) had the same elution volume also OPEII and LPEII had the same elution volume. A higher concentration of NaCl was required at all pH values for optimum activity of OPEI and LPEI than of OPEII and LPEII. When the component parts of oranges were separately analyzed chromatographi-cally with DEAE-Sephadex A-50, OPEI was detected only in the peel, whereas OPEII was identified in juice sacs and section walls (AO). [Pg.157]

The inert gas content is analyzed volumetrically after the vaporized ammonia has been absorbed in water. Then the inert gas composition is analyzed chromatographi-cally. [Pg.222]

Use the theory of linear chromatography with very small pulses to analyze chromatography systems... [Pg.876]

Other methods for analyzing combustion products can be substituted for chromatography. Gravimetry can be used, for example, after a series of absorption on different beds, as in the case of water absorption in magnesium perchlorate or CO2 in soda lime infra-red spectrometry can be used for the detection of CO2 and water. [Pg.29]

The material to be analyzed is pyrolyzed in an inert gas at 1100°C in the presence of carbon the carbon monoxide formed, if any, is either analyzed directly by chromatography or analyzed as carbon dioxide after oxidation by CuO. The CO2 is detected by infra-red spectrometry or by gas phase chromatography. [Pg.30]

Distillation simulated by gas chromatography is a reproducible method for analyzing a petroleum cut it is appiicabie for mixtures whose end point is less than 500°C and the boiling range is greater than 50°C. The results of this test are presented in the form of a curve showing temperature as a function of the weight per cent distilled equivalent to an atmospheric TBP. [Pg.103]

The Cj to Cg light components are analyzed by gas chromatography and the results are presented as weight per cents of the crude oii. [Pg.106]

A large number of variously 2-, 4-, and 5-substituted thiazoles with alkyl, aryl, hydroxy, methylthio, mercapto, halo, and nitro groups have been analyzed by thin-layer chromatography on silica and alumina by the Stahl s technique (167, 170, 172). Among the many systems recommended for the elution of these compounds are the following ... [Pg.362]

Preparing a Volatile Sample Gas chromatography can be used to separate analytes in complex matrices. Not every sample that can potentially be analyzed by GG, however, can be injected directly into the instrument. To move through the column, the sample s constituents must be volatile. Solutes of low volatility may be retained by the column and continue to elute during the analysis of subsequent samples. Nonvolatile solutes condense on the column, degrading the column s performance. [Pg.567]

Nonvolatile analytes must be chemically converted to a volatile derivative before analysis. For example, amino acids are not sufficiently volatile to analyze directly by gas chromatography. Reacting an amino acid with 1-butanol and acetyl chloride produces an esterfied amino acid. Subsequent treatment with trifluoroacetic acid gives the amino acid s volatile N-trifluoroacetyl- -butyl ester derivative. [Pg.568]

Despite their importance, gas chromatography and liquid chromatography cannot be used to separate and analyze all types of samples. Gas chromatography, particularly when using capillary columns, provides for rapid separations with excellent resolution. Its application, however, is limited to volatile analytes or those analytes that can be made volatile by a suitable derivatization. Liquid chromatography can be used to separate a wider array of solutes however, the most commonly used detectors (UV, fluorescence, and electrochemical) do not respond as universally as the flame ionization detector commonly used in gas chromatography. [Pg.596]

A series of polyvinylpyridine standards of different molecular weight were analyzed by size-exclusion chromatography, yielding the following results. [Pg.619]

In many applications in mass spectrometry (MS), the sample to be analyzed is present as a solution in a solvent, such as methanol or acetonitrile, or an aqueous one, as with body fluids. The solution may be an effluent from a liquid chromatography (LC) column. In any case, a solution flows into the front end of a mass spectrometer, but before it can provide a mass spectrum, the bulk of the solvent must be removed without losing the sample (solute). If the solvent is not removed, then its vaporization as it enters the ion source would produce a large increase in pressure and stop the spectrometer from working. At the same time that the solvent is removed, the dissolved sample must be retained so that its mass spectrum can be measured. There are several means of effecting this differentiation between carrier solvent and the solute of interest, and thermospray is just one of them. Plasmaspray is a variant of thermospray in which the basic method of solvent removal is the same, but the number of ions obtained is enhanced (see below). [Pg.71]

This chapter provides brief descriptions of analyzer layouts for three hybrid instruments. More extensive treatments of sector/TOF (AutoSpec-TOF), liquid chromatography/TOF (LCT or LC/TOF with Z-spray), and quadrupole/TOF (Q/TOF), are provided in Chapters 23, 22, and 21, respectively. [Pg.153]

Schematic diagram of an orthogonal Q/TOF instrument. In this example, an ion beam is produced by electrospray ionization. The solution can be an effluent from a liquid chromatography column or simply a solution of an analyte. The sampling cone and the skimmer help to separate analyte ions from solvent, The RF hexapoles cannot separate ions according to m/z values and are instead used to help confine the ions into a narrow beam. The quadrupole can be made to operate in two modes. In one (wide band-pass mode), all of the ion beam passes through. In the other (narrow band-pass mode), only ions selected according to m/z value are allowed through. In narrow band-pass mode, the gas pressure in the middle hexapole is increased so that ions selected in the quadrupole are caused to fragment following collisions with gas molecules. In both modes, the TOF analyzer is used to produce the final mass spectrum. Schematic diagram of an orthogonal Q/TOF instrument. In this example, an ion beam is produced by electrospray ionization. The solution can be an effluent from a liquid chromatography column or simply a solution of an analyte. The sampling cone and the skimmer help to separate analyte ions from solvent, The RF hexapoles cannot separate ions according to m/z values and are instead used to help confine the ions into a narrow beam. The quadrupole can be made to operate in two modes. In one (wide band-pass mode), all of the ion beam passes through. In the other (narrow band-pass mode), only ions selected according to m/z value are allowed through. In narrow band-pass mode, the gas pressure in the middle hexapole is increased so that ions selected in the quadrupole are caused to fragment following collisions with gas molecules. In both modes, the TOF analyzer is used to produce the final mass spectrum.
Mixtures passed through special columns (chromatography) in the gas phase (GC) or liquid phase (LC) can be separated into their individual components and analyzed qualitatively and/or quantitatively. Both GC and LC analyzers can be directly coupled to mass spectrometers, a powerful combination that can simultaneously separate and identify components of mixtures. [Pg.252]

Determination of DMAC in Air. DMAC can be measured in air by passing a known amount of sample through water in a gas-scmbbing vessel and then analyzing the solution either chemically or by gas chromatography. [Pg.84]

Polyester composition can be determined by hydrolytic depolymerization followed by gas chromatography (28) to analyze for monomers, comonomers, oligomers, and other components including side-reaction products (ie, DEG, vinyl groups, aldehydes), plasticizers, and finishes. Mass spectroscopy and infrared spectroscopy can provide valuable composition information, including end group analysis (47,101,102). X-ray fluorescence is commonly used to determine metals content of polymers, from sources including catalysts, delusterants, or tracer materials added for fiber identification purposes (28,102,103). [Pg.332]

Blood and urine are most often analyzed for alcohol by headspace gas chromatography (qv) using an internal standard, eg, 1-propanol. Assays are straightforward and lend themselves to automation (see Automated instrumentation). Urine samples are collected as a voided specimen, ie, subjects must void their bladders, wait about 20 minutes, and then provide the urine sample. Voided urine samples provide the most accurate deterrnination of blood alcohol concentrations. Voided urine alcohol concentrations are divided by a factor of 1.3 to determine the equivalent blood alcohol concentration. The 1.3 value is used because urine has approximately one-third more water in it than blood and, at equiUbrium, there is about one-third more alcohol in the urine as in the blood. [Pg.486]

Most immunoassay kits and many commercial immunoassay analyzers are based on heterogenous EIA or FIA. These include an immunoassay system that uses FIA linked to radial partition chromatography of the antibody—antigen complex (39) a system that uses antibody-coated tubes for enzyme immunoassay of a variety of hormones and dmgs (40) and a system that uses either a sandwich or competitive FIA format to measure a variety of analytes (41). [Pg.28]

Finally, the techniques of nmr, infrared spectroscopy, and thin-layer chromatography also can be used to assay maleic anhydride (172). The individual anhydrides may be analyzed by gas chromatography (173,174). The isomeric acids can be determined by polarography (175), thermal analysis (176), paper and thin-layer chromatographies (177), and nonaqueous titrations with an alkaU (178). Maleic and fumaric acids may be separated by both gel filtration (179) and ion-exchange techniques (180). [Pg.459]

Analytical and Test Methods. Potentiometic titration is an analytical method for cyanoacetic acid. Methyl and ethyl cyanoacetates are usually analyzed by gas chromatography usiag the same equipment as for the malonates but with a higher column and iajector temperatures, namely 150 and 200°C, respectively. [Pg.471]

Analytical and Test Methods. o-Nitrotoluene can be analyzed for purity and isomer content by infrared spectroscopy with an accuracy of about 1%. -Nitrotoluene content can be estimated by the decomposition of the isomeric toluene diazonium chlorides because the ortho and meta isomers decompose more readily than the para isomer. A colorimetric method for determining the content of the various isomers is based on the color which forms when the mononitrotoluenes are dissolved in sulfuric acid (45). From the absorption of the sulfuric acid solution at 436 and 305 nm, the ortho and para isomer content can be deterrnined, and the meta isomer can be obtained by difference. However, this and other colorimetric methods are subject to possible interferences from other aromatic nitro compounds. A titrimetric method, based on the reduction of the nitro group with titanium(III) sulfate or chloride, can be used to determine mononitrotoluenes (32). Chromatographic methods, eg, gas chromatography or high pressure Hquid chromatography, are well suited for the deterrnination of mononitrotoluenes as well as its individual isomers. Freezing points are used commonly as indicators of purity of the various isomers. [Pg.70]

High performance Hquid chromatography (hplc) may be used to determine nitroparaffins by utilizing a standard uv detector at 254 nm. This method is particularly appHcable to small amounts of nitroparaffins present, eg, in nitro alcohols (qv), which caimot be analyzed easily by gas chromatography. Suitable methods for monitoring and deterrnination of airborne nitromethane, nitroethane, and 2-nitropropane have been pubUshed by the National Institute of Occupational Safety and Health (NIOSH) (97). Ordinary sorbant tubes containing charcoal are unsatisfactory, because the nitroparaffins decompose on it unless the tubes are held in dry ice and analyzed as soon after collection as possible. [Pg.103]

Cyclic Peroxides. CycHc diperoxides (4) and triperoxides (5) are soHds and the low molecular weight compounds are shock-sensitive and explosive (151). The melting points of some characteristic compounds of this type are given in Table 5. They can be reduced to carbonyl compounds and alcohols with zinc and alkaH, zinc and acetic acid, aluminum amalgam, Grignard reagents, and warm acidified iodides (44,122). They are more difficult to analyze by titration with acidified iodides than the acycHc peroxides and have been sucessfuUy analyzed by gas chromatography (112). [Pg.116]

Gas chromatography (gc) has been used extensively to analyze phenoHc resins for unreacted phenol monomer as weU as certain two- and three-ring constituents in both novolak and resole resins (61). It is also used in monitoring the production processes of the monomers, eg, when phenol is alkylated with isobutylene to produce butylphenol. Usually, the phenoHc hydroxyl must be derivatized before analysis to provide a more volatile compound. The gc analysis of complex systems, such as resoles, provides distinct resolution of over 20 one- and two-ring compounds having various degrees of methylolation. In some cases, hemiformals may be detected if they have been properly capped (53). [Pg.300]

The combined techniques of gas chromatography/mass spectrometry (gc/ms) are highly effective in identifying the composition of various gc peaks. The individual peaks enter a mass spectrometer in which they are analyzed for parent ion and fragmentation patterns, and the individual components of certain resoles are completely resolved. [Pg.300]


See other pages where Analyzers chromatography is mentioned: [Pg.81]    [Pg.573]    [Pg.578]    [Pg.589]    [Pg.610]    [Pg.55]    [Pg.102]    [Pg.261]    [Pg.366]    [Pg.134]    [Pg.276]    [Pg.130]    [Pg.15]    [Pg.49]    [Pg.287]    [Pg.378]    [Pg.539]    [Pg.539]    [Pg.108]    [Pg.132]    [Pg.300]   