Special Columns

Mixtures passed through special columns (chromatography) in the gas phase (GC) or liquid phase (LC) can be separated into their individual components and analyzed qualitatively and/or quantitatively. Both GC and LC analyzers can be directly coupled to mass spectrometers, a powerful combination that can simultaneously separate and identify components of mixtures. [Pg.252]

MLC enables to analyse drugs and active phamiaceutical substances without using special column and lai ge quantity of organic solvents. So, from the point of view of pharmaceutical analysis ecology and green chemistry conception, assay with MLC using will be better than conventional reversed-phase chromatography. [Pg.390]

Preparative chromatography involves the collection of individual solutes as they are eluted from the column for further use, but does not necessarily entail the separation of large samples. Special columns can be designed and fabricated for preparative use, but for small samples the analytical column can often be overloaded for preparative purposes. Columns can be either volume overloaded or mass overloaded. Volume overload causes the peak to broaden, but the retention time of the front of the peak... [Pg.439]

AChE-biotests are located in a special column-reactor connected with the peristaltic pump and the incubation is done in flowing conditions. For this purpose special flowing, termistatic column-reactor is used (described in Supplement 2). [Pg.152]

A problem of particular importance in quantum theory is the calculation of special column vectors x and the eigenvalues A associated with a given square matrix A, by the equation... [Pg.19]

Typical instrument set-ups for online sample preparation, for example, solid phase extraction and sample pre-concentration, require the control of a six-port valve with an additional special column and a second pump. Ideally, this system will be fully controlled by the data acquisition software (Figure 3.12 (A)). [Pg.112]

High Molecular Weight Polymers in Cyclohexane and also in Special Column Arrangements. Waters Associates Ana-Prep and 501 GPC were used. One four-foot Styragel column of 5x10 pore size was connected to a pump and a differential refractometer detector to determine the effect of fritted discs on degradation. [Pg.230]

During the past two decades, innovative LC techniques have been perfected that improved separation, purification, identification, and quantification far above early techniques (1-7). The last decade, in particular, has seen a vast development of micro- and other specialized columns as well as a variety of detectors, computers, and automation to interface with the LC to arrive at optimal analysis of the analytes (8-13). [Pg.664]

Arrhenius plot), and the maximuna difference in A (A log A) are given in special columns. [Pg.80]

There are many factors to consider in selecting a column for a specific separation. Table 3.3 lists a variety of applications along with columns that have been found suitable for each analysis. While each of these columns has been used successfully for the class of compounds shown, they will not separate all compounds of that class. Separation of isomers can be difficult and special columns are often required. However, the columns listed are useful for the first step in the analytical problem. [Pg.138]

One variation of gel chromatography is ascending eluent flow. Some investigators report more reproducible results, better resolution, and a more constant flow rate if the eluting buffer is pumped backward through the gel. This type of experiment requires special equipment, including a specialized column and a peristaltic pump. [Pg.85]

Two runs at high CO2 concentrations (9.8 mole percent CO2/ N2/5A 1/4" and 13.2 mole percent C02/air/5A 1/8" LMS pellets), for which it was determined that effects of heat transfer could be very important, were run in a special column designed by F. W. Leavitt (developer of the MASC program) to simulate essentially adiabatic behavior. The column was constructed of thin-walled sheet metal and was 24.8 cm in diameter. Electric heating jackets placed in sections along the wall of the column and controlled by thermocouples placed at corresponding intervals along the centerline of the bed were used to maintain the wall at essentially the same temperature as the bed interior. [Pg.88]

Oximation takes place in a special column by means of countercurrent flow of cyclohexanone and hydroxylamine solution with 97 to 98% conversion. Temperature is kept above the melting point of cyclohexanone oxime264. [Pg.380]

The basic configuration and optional setup of the expanded-bed operation is shown in Fig. 5. In addition to the special column, there is a need for two pumps and a set of valves to control the flow to and from the column. Columns for expanded-bed adsorption are commercially available from vari-... [Pg.437]

Doring (39) has shown that infinite dilution relative volatilities can be evaluated through GLC. He prepared a special column for each solvent under consideration, a tedious project. A year later Sheets and Marchello (38) showed that separation factors increase with increased amounts of injected solvent. Later Tassios (35) found out the same to... [Pg.68]

Satisfactory results are obtained with compounds of different nature. Of particular interest is the case of basic compounds, such as phenethylamines and 3-blockers, which experience large efficiency enhancements in SDS systems.This makes the use of special columns less necessary. The surfactant layer adsorbed on the column prevents the interaction of basic compounds with free silanol groups, which accounts for the low efficiencies observed with conventional columns in aqueous-organic RPLC. For acidic compounds such as sulfonamides, the efficiencies are comparable with both MLC and conventional RPLC, but for low polar compounds such as steroids, efficiencies are comparably poorer in MLC. However, in this technique, low polar steroids are eluted at sufficiently short retention times via a small amount of... [Pg.812]

Despite this progress, SEC with HFIP remains an expensive procedure due to extra investment in fluorinated solvent and special columns. Finally, it should be noted that HFIP with a of 9.3 is sufficiently acidic to react with the nitrogen in aromatic polyimides, resulting in ring-opening solvolysis. [Pg.1219]

At present, ten different anion exchangers (IonPac AS1 to AS7) with diverse selectivities are available from Dionex. The structural and technical characteristics of these separator columns are summarized in Table 3-4. Additionally, special columns for the fast separation of simple inorganic anions, for the separation of bromide, nitrate, and chlorate, as well as for the anion exchange chromatography of amino acids are available. [Pg.43]

Turbulent flow chromatography is a direct-inject sample-preparation technique that is accomplished on a special chromatography column. The technique has some applicability toward plasma and serum. The special column combines large particle (50 lm) and frit size (20 lm) with high flow rate (5 to 10 mL/ min) to achieve eddies and nonlaminar flow. Under this arrangement, improved... [Pg.191]


See other pages where Special Columns is mentioned: [Pg.300]    [Pg.1321]    [Pg.54]    [Pg.430]    [Pg.184]    [Pg.244]    [Pg.24]    [Pg.715]    [Pg.222]    [Pg.131]    [Pg.670]    [Pg.48]    [Pg.48]    [Pg.72]    [Pg.208]    [Pg.263]    [Pg.57]    [Pg.14]    [Pg.96]    [Pg.1144]    [Pg.187]    [Pg.30]    [Pg.526]    [Pg.54]    [Pg.115]    [Pg.1530]    [Pg.115]    [Pg.52]    [Pg.53]   