Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analytical methods examples

Many analytical methods (Examples 2 and 4) cannot be directly or indirectly linked to Si-units with any of the available primary methods of measurement. These can only be used in exceptional cases for a limited range of rather simple problems. Hence, many methods of analysis rely on other methods for the assessment of their accuracy. The instrumentation and measurement process used must be transparent and a full account of sources of error, relative and absolute, must be made. Unfortunately, as Examples 2 and 3 show, with the growing complexity of analytical methods this transparency becomes a major headache for both metrologists and analytical chemists. The relationship between signals measured and the derived concentration becomes a complex calculation [6] and the result of a measurement in many methods can only be traceable to the instrument, its electronics and integrated software [33],... [Pg.42]

As we shall see, this volume concentrates on methods which are stochastic, rather than deterministic, in nature - that is, the route that they take in seeking a solution depends in some way upon chance (and, as an important consequence, the solution found may vary from one invocation of the algorithm to the next). Although stochastic methods are not as familiar to most chemists as analytical methods, examples of their use are still widespread. Monte Carlo calculations, which combine a statistical approach with the chance nature of random events, have been widely used in fields such as molecular dynamics, but Monte Carlo is only suited to a restricted range of problems. [Pg.4]

Depth concentration measurement is an important application of surface analytical methods. Examples are depth distribution of additives in plastics, or interface analysis where polymers are in contact with metals or ceramics. All surface methods with a good depth resolution (XPS, AES, SIMS) are suitable for depth or profile measurements. Complete multilayer coating systems require analytical methods that are applicable to small sample sizes and low concentrations. Techniques for obtaining chemical composition and component distribution depth profiles for automotive coating systems, both in-plane (or slab) microtomy and cross-section microtomy, include /xETIR, /xRS, ToE-SIMS, optical microscopy, TEM, as well as solvent extraction followed by HPLC, as illustrated by Adamsons et al. [5]. Surface and interface/interphase analysis can now be done routinely on both simple monolayer coatings and complex multicomponent, multilayered... [Pg.460]

In the presence of many metal ions, diorthohydroxyazo dyes exhibit two polarographic reduction waves, the first due to free dye and the second to metal-dye complex. Highly sensitive analytical methods based on this principle have been developed for example, Ni or Fe may be determined in the presence of an excess of aluminum thank to thiazolylazo derivatives (563). [Pg.153]

Normality is an older unit of concentration that, although once commonly used, is frequently ignored in today s laboratories. Normality is still used in some handbooks of analytical methods, and, for this reason, it is helpful to understand its meaning. For example, normality is the concentration unit used in Standard Methods for the Examination of Water and Wastewaterf a commonly used source of analytical methods for environmental laboratories. [Pg.16]

Finally, analytical methods can be compared in terms of their need for equipment, the time required to complete an analysis, and the cost per sample. Methods relying on instrumentation are equipment-intensive and may require significant operator training. For example, the graphite furnace atomic absorption spectroscopic method for determining lead levels in water requires a significant capital investment in the instrument and an experienced operator to obtain reliable results. Other methods, such as titrimetry, require only simple equipment and reagents and can be learned quickly. [Pg.44]

When the analytical method s selectivity is insufficient, it may be necessary to separate the analyte from potential interferents. Such separations can take advantage of physical properties, such as size, mass or density, or chemical properties. Important examples of chemical separations include masking, distillation, and extractions. [Pg.224]

Charge-transfer absorption is important because it produces very large absorbances, providing for a much more sensitive analytical method. One important example of a charge-transfer complex is that of o-phenanthroline with Fe +, the UV/Vis spectrum for which is shown in Figure 10.17. Charge-transfer absorption in which the electron moves from the ligand to the metal also is possible. [Pg.382]

The determination of an analyte s concentration based on its absorption of ultraviolet or visible radiation is one of the most frequently encountered quantitative analytical methods. One reason for its popularity is that many organic and inorganic compounds have strong absorption bands in the UV/Vis region of the electromagnetic spectrum. In addition, analytes that do not absorb UV/Vis radiation, or that absorb such radiation only weakly, frequently can be chemically coupled to a species that does. For example, nonabsorbing solutions of Pb + can be reacted with dithizone to form the red Pb-dithizonate complex. An additional advantage to UV/Vis absorption is that in most cases it is relatively easy to adjust experimental and instrumental conditions so that Beer s law is obeyed. [Pg.394]

Controllcd-Currcnt Coulomctry The use of a mediator makes controlled-current coulometry a more versatile analytical method than controlled-potential coulome-try. For example, the direct oxidation or reduction of a protein at the working electrode in controlled-potential coulometry is difficult if the protein s active redox site lies deep within its structure. The controlled-current coulometric analysis of the protein is made possible, however, by coupling its oxidation or reduction to a mediator that is reduced or oxidized at the working electrode. Controlled-current coulometric methods have been developed for many of the same analytes that may be determined by conventional redox titrimetry. These methods, several of which are summarized in Table 11.9, also are called coulometric redox titrations. [Pg.503]

Suppose we have a sample containing an analyte in a matrix that is incompatible with our analytical method. To determine the analyte s concentration we first separate it from the matrix using, for example, a liquid-liquid extraction. If there are additional analytes, we may need to use additional extractions to isolate them from the analyte s matrix. For a complex mixture of analytes this quickly becomes a tedious process. [Pg.544]

The earliest examples of analytical methods based on chemical kinetics, which date from the late nineteenth century, took advantage of the catalytic activity of enzymes. Typically, the enzyme was added to a solution containing a suitable substrate, and the reaction between the two was monitored for a fixed time. The enzyme s activity was determined by measuring the amount of substrate that had reacted. Enzymes also were used in procedures for the quantitative analysis of hydrogen peroxide and carbohydrates. The application of catalytic reactions continued in the first half of the twentieth century, and developments included the use of nonenzymatic catalysts, noncatalytic reactions, and differences in reaction rates when analyzing samples with several analytes. [Pg.623]

Noncatalytic Reactions Chemical kinetic methods are not as common for the quantitative analysis of analytes in noncatalytic reactions. Because they lack the enhancement of reaction rate obtained when using a catalyst, noncatalytic methods generally are not used for the determination of analytes at low concentrations. Noncatalytic methods for analyzing inorganic analytes are usually based on a com-plexation reaction. One example was outlined in Example 13.4, in which the concentration of aluminum in serum was determined by the initial rate of formation of its complex with 2-hydroxy-1-naphthaldehyde p-methoxybenzoyl-hydrazone. ° The greatest number of noncatalytic methods, however, are for the quantitative analysis of organic analytes. For example, the insecticide methyl parathion has been determined by measuring its rate of hydrolysis in alkaline solutions. [Pg.638]

Quantitative analytical methods using FIA have been developed for cationic, anionic, and molecular pollutants in wastewater, fresh waters, groundwaters, and marine waters, several examples of which were described in the previous section. Table 13.2 provides a partial listing of other analytes that have been determined using FIA, many of which are modifications of conventional standard spectropho-tometric and potentiometric methods. An additional advantage of FIA for environmental analysis is its ability to provide for the continuous, in situ monitoring of pollutants in the field. ... [Pg.655]

An analysis of variance can be extended to systems involving more than a single variable. For example, a two-way ANOVA can be used in a collaborative study to determine the importance to an analytical method of both the analyst and the instrumentation used. The treatment of multivariable ANOVA is beyond the scope of this text, but is covered in several of the texts listed as suggested readings at the end of the chapter. [Pg.697]

The level of quahty required in a LIMS is related to the particular role played by the system in the organi2ation s business. In an R D environment, for example, the primary reason for a LIMS might be to compare and document new analytical methods. [Pg.517]

Air Monitoring. The atmosphere in work areas is monitored for worker safety. Volatile amines and related compounds can be detected at low concentrations in the air by a number of methods. Suitable methods include chemical, chromatographic, and spectroscopic techniques. For example, the NIOSH Manual of Analytical Methods has methods based on gas chromatography which are suitable for common aromatic and aHphatic amines as well as ethanolamines (67). Aromatic amines which diazotize readily can also be detected photometrically using a treated paper which changes color (68). Other methods based on infrared spectroscopy (69) and mass spectroscopy (70) have also been reported. [Pg.264]

Materials characterization techniques, ie, atomic and molecular identification and analysis, ate discussed ia articles the tides of which, for the most part, are descriptive of the analytical method. For example, both iaftared (it) and near iaftared analysis (nira) are described ia Infrared and raman SPECTROSCOPY. Nucleai magaetic resoaance (nmr) and electron spia resonance (esr) are discussed ia Magnetic spin resonance. Ultraviolet (uv) and visible (vis), absorption and emission, as well as Raman spectroscopy, circular dichroism (cd), etc are discussed ia Spectroscopy (see also Chemiluminescence Electho-analytical techniques It unoassay Mass specthot thy Microscopy Microwave technology Plasma technology and X-ray technology). [Pg.393]

Analytical Methods. A classical and stiU widely employed analytical method is iodimetric titration. This is suitable for determination of sodium sulfite, for example, in boiler water. Standard potassium iodate—potassium iodide solution is commonly used as the titrant with a starch or starch-substitute indicator. Sodium bisulfite occurring as an impurity in sodium sulfite can be determined by addition of hydrogen peroxide to oxidize the bisulfite to bisulfate, followed by titration with standard sodium hydroxide (279). [Pg.149]

A number of analytical methods have been developed for the determination of chlorotoluene mixtures by gas chromatography. These are used for determinations in environments such as air near industry (62) and soil (63). Liquid crystal stationary columns are more effective in separating m- and chlorotoluene than conventional columns (64). Prepacked columns are commercially available. ZeoHtes have been examined extensively as a means to separate chlorotoluene mixtures (see Molecularsieves). For example, a Y-type 2eohte containing sodium and copper has been used to separate y -chlorotoluene from its isomers by selective absorption (65). The presence of ben2ylic impurities in chlorotoluenes is determined by standard methods for hydroly2able chlorine. Proton (66) and carbon-13 chemical shifts, characteristic in absorption bands, and principal mass spectral peaks are available along with sources of reference spectra (67). [Pg.54]

The use of agarose as an electrophoretic method is widespread (32—35). An example of its use is in the evaluation and typing of DNA both in forensics (see Forensic chemistry) and to study heritable diseases (36). Agarose electrophoresis is combined with other analytical tools such as Southern blotting, polymerase chain reaction, and fluorescence. The advantages of agarose electrophoresis are that it requires no additives or cross-linkers for polymerization, it is not hazardous, low concentration gels are relatively sturdy, it is inexpensive, and it can be combined with many other analytical methods. [Pg.182]

Two-Dimensional Electrophoresis. Two-dimensional (2D) electrophoresis is unique, offering an analytical method that is both reproducible and sensitive. It is referred to as 2D because it employs two different methods of electrophoresis, in two different dimensions, to produce one result. Each method separates the sample compounds based on different properties of each compound. The combination of the two methods gives better resolution of the compounds in the sample than could be achieved with either method alone. For example, each method alone may separate up to 100 components of a sample, whereas together they may separate up to 10,000 components. [Pg.184]

In looking for the mechanism, many intermediates are assumed. Some of these are stable molecules in pure form but very active in reacting systems. Other intermediates are in very low concentration and can be identified only by special analytical methods, like mass spectrometry (the atomic species of hydrogen and halogens, for example). These are at times referred to as active centers. Others are in transition states that the reacting cheimicals form with atoms or radicals these rarely can be isolated. In heterogeneous catalytic reaction, the absorbed reactant can... [Pg.115]

Each type of mass spectrometer has its associated advantages and disadvantages. Quadrupole-based systems offer a fairly simple ion optics design that provides a certain degree of flexibility with respect to instrument configuration. For example, quadrupole mass filters are often found in hybrid systems, that is, coupled with another surface analytical method, such as electron spectroscopy for chemical analysis or scanning Auger spectroscopy. [Pg.552]

It is often experimentally convenient to use an analytical method that provides an instrumental signal that is proportional to concentration, rather than providing an absolute concentration, and such methods readily yield the ratio clc°. Solution absorbance, fluorescence intensity, and conductance are examples of this type of instrument response. The requirements are that the reactants and products both give a signal that is directly proportional to their concentrations and that there be an experimentally usable change in the observed property as the reactants are transformed into the products. We take absorption spectroscopy as an example, so that Beer s law is the functional relationship between absorbance and concentration. Let A be the reactant and Z the product. We then require that Ea ez, where e signifies a molar absorptivity. As initial conditions (t = 0) we set Ca = ca and cz = 0. The mass balance relationship Eq. (2-47) relates Ca and cz, where c is the product concentration at infinity time, that is, when the reaction is essentially complete. [Pg.34]

Exploitation of analytical selectivity. We have seen, in our discussion of the A —> B C series reaction (Scheme IX), that access to the concentration of A as a function of time is valuable because it permits to be easily evaluated. Modern analytical methods, particularly chromatography, constitute a powerful adjunct to kinetic investigations, and they render nearly obsolete some very difficult kinetic problems. For example, the freedom to make use of the pseudoorder technique is largely dependent upon the high sensitivity of analytical methods, which allows us to set one reactant concentration much lower than another. An interesting example of analytical control in the study of the Scheme IX system is the spectrophotometric observation of the reaction solution at an isosbestic point of species B and C, thus permitting the A to B step to be observed. [Pg.79]

If, in the above example, the analytical error was 0.2 per cent then the total error sT would be equal to 3.006 per cent. Hence the contribution of the analytical error to the total error is virtually insignificant. Youden7 has stated that once the analytical uncertainty is reduced to one-third of the sampling uncertainty, further reduction of the former is not necessary. It is most important to realise that if the sampling error is large, then a rapid analytical method with relatively low precision may suffice. [Pg.152]


See other pages where Analytical methods examples is mentioned: [Pg.2903]    [Pg.77]    [Pg.21]    [Pg.40]    [Pg.50]    [Pg.150]    [Pg.174]    [Pg.201]    [Pg.257]    [Pg.331]    [Pg.361]    [Pg.276]    [Pg.416]    [Pg.108]    [Pg.509]    [Pg.6]    [Pg.504]    [Pg.153]    [Pg.348]    [Pg.69]    [Pg.348]    [Pg.179]    [Pg.102]    [Pg.140]   
See also in sourсe #XX -- [ Pg.23 , Pg.128 , Pg.138 ]




SEARCH



Analytical examples

© 2024 chempedia.info