Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Activity and passivity

Another distinction we make concerning synnnetry operations involves the active and passive pictures. Below we consider translational and rotational symmetry operations. We describe these operations in a space-fixed axis system (X,Y,Z) with axes parallel to the X, Y, Z) axes, but with the origin fixed in space. In the active picture, which we adopt here, a translational symmetry operation displaces all nuclei and electrons in the molecule along a vector, say. [Pg.155]

Lee D and Albrecht A C 1993 On global energy conservation in nonlinear light matter interaction the nonlinear spectroscopies, active and passive Adv. Phys. Chem. 83 43-87... [Pg.1225]

In humans, thiamine is both actively and passively absorbed to a limited level in the intestines, is transported as the free vitamin, is then taken up in actively metabolizing tissues, and is converted to the phosphate esters via ubiquitous thiamine kinases. During thiamine deficiency all tissues stores are readily mobilhed. Because depletion of thiamine levels in erythrocytes parallels that of other tissues, erythrocyte thiamine levels ate used to quantitate severity of the deficiency. As deficiency progresses, thiamine becomes indetectable in the urine, the primary excretory route for this vitamin and its metaboHtes. Six major metaboHtes, of more than 20 total, have been characterized from human urine, including thiamine fragments (7,8), and the corresponding carboxyHc acids (1,37,38). [Pg.88]

Fig. 2. Schematic representation of relevant electrolyte transport through the renal tubule, depicting the osmolar gradient ia medullary iaterstitial fluid ia ywOj yW where represents active transport, —passive transport, hoth active and passive transport, and passive transport of H2O ia the presence of ADH, ia A, the cortex, and B, the medulla. An osmole equals a mole of solute divided by the number of ions formed per molecule of the solute. Thus one mole of sodium chloride is equivalent to two osmoles, ie, lAfNaCl = 2 Osm NaCl. ADH = antidiuretic hormone. Fig. 2. Schematic representation of relevant electrolyte transport through the renal tubule, depicting the osmolar gradient ia medullary iaterstitial fluid ia ywOj yW where represents active transport, —passive transport, hoth active and passive transport, and passive transport of H2O ia the presence of ADH, ia A, the cortex, and B, the medulla. An osmole equals a mole of solute divided by the number of ions formed per molecule of the solute. Thus one mole of sodium chloride is equivalent to two osmoles, ie, lAfNaCl = 2 Osm NaCl. ADH = antidiuretic hormone.
Electrochemical cells may be used in either active or passive modes, depending on whether or not a signal, typically a current or voltage, must be actively appHed to the cell in order to evoke an analytically usehil response. Electroanalytical techniques have also been divided into two broad categories, static and dynamic, depending on whether or not current dows in the external circuit (1). In the static case, the system is assumed to be at equilibrium. The term dynamic indicates that the system has been disturbed and is not at equilibrium when the measurement is made. These definitions are often inappropriate because active measurements can be made that hardly disturb the system and passive measurements can be made on systems that are far from equilibrium. The terms static and dynamic also imply some sort of artificial time constraints on the measurement. Active and passive are terms that nonelectrochemists seem to understand more readily than static and dynamic. [Pg.49]

Two basic mechanisms cause biological corrosion. Biologically produced substances may actively or passively cause attack. Each mechanism either accelerates preexisting corrosion or establishes a new form of metal loss. Often the distinction between active and passive attack is vague. [Pg.119]

The active and passive electrochemical processes on which present-day corrosion protection is based were already known in the 19th century, but reliable protection for pipelines only developed at the turn of the 20th century. [Pg.1]

Corrosion protection measures are divided into active and passive processes. Electrochemical corrosion protection plays an active part in the corrosion process by changing the potential. Coatings on the object to be protected keep the aggressive medium at a distance. Both protection measures are theoretically applicable on their own. However, a combination of both is requisite and beneficial for the following reasons ... [Pg.153]

Since the object to be protected represents a cell consisting of active and passive steel, considerable IR errors in the cell current must be expected in measuring the off potential. The considerations in Section 3.3.1 with reference to Eqs. (3-27) and (3-28) are relevant here. Since upon switching off the protection current, 7, the nearby cathodes lead to anodic polarization of a region at risk from corrosion, the cell currents and 7, have opposite signs. It follows from Eqs. (3-27) and (3-28) that the 77 -free potential must be more negative than the off potential. Therefore, there is greater certainty of the potential criterion in Eq. (2-39). [Pg.437]

It is known that the common austenitic stainless steels have sufficient corrosion resistance in sulfuric acid of lower concentrations (<20%) and higher concentrations (>70%) below a critical temperature. If with higher concentrations of sulfuric acid (>90%) a temperature of 70°C is exceeded, depending on their composition, austenitic stainless steels can exhibit more or less pronounced corrosion phenomena in which the steels can fluctuate between the active and passive state [19]. [Pg.478]

This ordering by singles, doubles and triples takes added meaning when the failure rates of the active and passive components (Table 1.4.3-1) are included. A doublet has a failure frequency that is the product of the two failure rates a triplet is the product of three... [Pg.9]

Mitigation System Resmnses Dikes and drainage. Hares, Fire protection systems (active and passive). Explosion vents. Toxic gas absorption... [Pg.301]

Failures can occur in two general types of equipment—active and passive— explained as follows ... [Pg.8]

There are a number of failure modes for the three failure severities and for active and passive equipment. Figures 2.1 and 2.2 illustrate these failure modes and severities by type of equipment. [Pg.8]

Potential-current density (E-i) curves, which have been determined for a number of the austenitic cast irons and also for the nickel-free ferritic irons, indicate that in general the austenitic cast irons show more favourable corrosion characteristics than the ferritic irons in both the active and passive states. [Pg.601]

Similar curves determined in 50 Vo sodium hydroxide solution at 60°C show (Fig. 3.46) that the austenitic irons exhibit more noble active dissolution and also lower current densities in the active and passive regions than the ferritic irons the current densities in both regions decrease markedly with increasing nickel content (Fig. 3.47). [Pg.603]

Fig. 3.47 Current densities in active and passive regions for ferrite and austenitic cast irons... Fig. 3.47 Current densities in active and passive regions for ferrite and austenitic cast irons...
Hitzig et al. have produced a simplified model of the aluminium oxide layer(s) to explain impedance data of specimens prepared under different layer formation and sealing conditionsThe model also gives consideration to the formation of active and passive pits in the oxide layer. Shaw et al. have shown that it is possible to electrochemically incorporate molybdenum into the passive film which, as previously noted, improves the pitting resistance. [Pg.677]

Active and passive immunity involve tiie use of agents that stimulate antibody formation (active immunity) or tiie injection of ready-made antibodies found in tiie serum of immune individuals or animals (passive immunity). The following sections describe active and passive immunity. [Pg.568]

In the polarization curve for anodic dissolution of iron in a phosphoric acid solution without CP ions, as shown in Fig. 3, we can see three different states of metal dissolution. The first is the active state at the potential region of the less noble metal where the metal dissolves actively, and the second is the passive state at the more noble region where metal dissolution barely proceeds. In the passive state, an extremely thin oxide film called a passive film is formed on the metal surface, so that metal dissolution is restricted. In the active state, on the contrary, the absence of the passive film leads to the dissolution from the bare metal surface. The difference of the dissolution current between the active and passive states is quite large for a system of an iron electrode in 1 mol m"3 sulfuric acid, the latter value is about 1/10,000 of the former value.6... [Pg.222]

Luminescence yields data that often cannot be provided by any other methodology. This book is a compilation of a wide variety of original research contributions. Substantial information is given on the use of luminescence techniques to understand specific cell responses and the chemical mechanisms of cell action. An examination of natural environments is presented in the form of specific studies that characterize materials in both solid and liquid form and give information on the respective reactions of these materials in soil and water systems. Advanced research on standardization and standards developed for luminescence studies, as well as both active and passive use of luminescence, is included. [Pg.258]

Arimura A, Nagata M, Takeuchi M, Watanabe A, Nakamura K, Harada M Active and passive cutaneous anaphylaxis in WBB6F1 mouse, a mast cell-deficient strain. Immunol Invest 1990 19 227-233. [Pg.96]

Modern representations of the virtual heart, therefore, describe structural aspects like fibre orientation in cardiac muscle, together with the distribution of various cell types, active and passive electrical and mechanical properties, as well as the coupling between cells. This then allows accurate reproduction of the spread of the electrical wave, subsequent contraction of the heart, and effects on blood pressure, coronary perfusion, etc. It is important to point out, here, that all these parameters are closely interrelated, and changes in any one of them influence the behaviour of all others. This makes for an exceedingly complex system. [Pg.137]

Mechanisms of active and passive transport in a family of homologous sugar transporters found in both prokaryotes and eukaryotes... [Pg.169]

Yeasts contain a large number of different active and passive sugar-transport systems. The first of these to be cloned was the glucose-repressible, high-affinity passive glucose transporter of Saccharomyces cerevisiae, which is encoded by the SNF3 gene... [Pg.200]

When the polarization curve is recorded in the opposite (cathodic) direction, the electrode will regain its active state at a certain potential The activation potential is sometimes called the Flade potential (Flade, 1911). The potentials of activation and passivation as a rule are slightly different. [Pg.306]


See other pages where Activity and passivity is mentioned: [Pg.249]    [Pg.530]    [Pg.415]    [Pg.331]    [Pg.203]    [Pg.123]    [Pg.365]    [Pg.178]    [Pg.141]    [Pg.219]    [Pg.137]    [Pg.211]    [Pg.641]    [Pg.1161]    [Pg.1171]    [Pg.227]    [Pg.573]    [Pg.223]    [Pg.155]    [Pg.170]    [Pg.170]    [Pg.201]    [Pg.93]   


SEARCH



Active-passive

© 2024 chempedia.info