Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Standardization and data on concentrations

TLV The TLV or Threshold Limit Value refers to a safe level of exposure by inhalation. The definition was established by the American Conference of Governmental Hygienists. There are several variations or criteria levels for the TLV. As an example, hydrogen sulfide has a TLV for short-term exposure limits (STEL) of 15 minutes of only 5 ppm. Comparing this to the TLV-STEL of 400 ppm for carbon monoxide provides an indication of the need to be extremely careful when H2S is suspected. Under OSHA Standards, and particularly on MSDS (Material Safety Data Sheets) compounds are associated with a time weighted average (TWA) TLV, which is the allowable concentration for an 8-hour continuous exposure period. For firefighting purposes, the short-term exposure is likely more realistic. [Pg.260]

In the absence of a standard source of NO, nitric acid vapor appears useful as a secondary standard since data on the HN03 content of saturated nitric acid as a function of concentration and temperature are available (3). However, in order to avoid high values, the acid should be boiled to remove the dissolved N02 or NO usually present (as indicated by brown coloration). [Pg.27]

The method is based on the international standard ISO 4053/IV. A small amount of the radioactive tracer is injected instantaneously into the flare gas flow through e.g. a valve, representing the only physical interference with the process. Radiation detectors are mounted outside the pipe and the variation of tracer concentration with time is recorded as the tracer moves with the gas stream and passes by the detectors. A control, supply and data registration unit including PC is used for on site data treatment... [Pg.1054]

Auxiliary data are the sizes of bubbles and droplets. These data and the holdups of the two phases are measured by a variety of standard techniques. Interfacial area measurements utihze techniques of transmission or reflection of light. Data on and methods for finding sohi-bihties of gases or the relation between partial pressure and concentration in hquid are also well estabhshecT... [Pg.2109]

The method was validated in accordance to the guidelines of the international conference on harmonization (ICH). Data with respect to accuracy, within- and between run precision, recovery, detection and quantitation limits were reported and found to be within the accepted international criteria. Neither endogeneous substances nor the commonly used dmgs were found to interfere with the retention times of the analytes. Standard solutions of the dmg and quality control preparations at high and low level concentrations were demonstrated to be stable at room temperature and/or -20°C for long and short periods of time. [Pg.395]

In the technological approach, qualitative and quantitative inforraatioii on emissions released by various production and work processes, as well as data on control technology performance, are required in order to specify the air quality target levels that are technically and economically feasible. The approach is based on information on current concentration levels that are achieved by different control technologies, ranging from standard practices to the most advanced technology options (Fig. 6.7). [Pg.399]

Titrimetric analysis is a classical method for generating concentration-time data, especially in second-order reactions. We illustrate with data on the acetylation of isopropanol (reactant B) by acetic anhydride (reactant A), catalyzed by A-methyl-imidazole. The kinetics were followed by hydrolyzing 5.0-ml samples at known times and titrating with standard base. A blank is carried out with the reagents but no alcohol. The reaction is... [Pg.32]

The most widely used molecular weight characterization method has been GPC, which separates compounds based on hydrodynamic volume. State-of-the-art GPC instruments are equipped with a concentration detector (e.g., differential refractometer, UV, and/or IR) in combination with viscosity or light scattering. A viscosity detector provides in-line solution viscosity data at each elution volume, which in combination with a concentration measurement can be converted to specific viscosity. Since the polymer concentration at each elution volume is quite dilute, the specific viscosity is considered a reasonable approximation for the dilute solution s intrinsic viscosity. The plot of log[r]]M versus elution volume (where [) ] is the intrinsic viscosity) provides a universal calibration curve from which absolute molecular weights of a variety of polymers can be obtained. Unfortunately, many reported analyses for phenolic oligomers and resins are simply based on polystyrene standards and only provide relative molecular weights instead of absolute numbers. [Pg.385]

An enthalpy of reaction also depends on the conditions (such as the pressure). All the tables in this book list data for reactions in which each reactant and product is in its standard state, its pure form at exactly 1 bar. The standard state of liquid water is pure water at 1 bar. The standard state of ice is pure ice at 1 bar. A solute in a liquid solution is in its standard state when its concentration is 1 mol-L". The standard value of a property X (that is, the value of X for the standard state of the substance) is denoted X°. [Pg.364]

Calculations for Rp as a function of the relevant experimental parameters (eluant ionic species concentration-including surfactant, packing diameter, eluant flow rate) and particle physical and electrochemical properties (Hamaker constant and surface potential) show good agreement with published data (l8,19) Of particiilar interest is the calculation which shows that at very low ionic concentration the separation factor becomes independent of the particle Hamaker constant. This result indicates the feasibility of xmiversal calibration based on well characterized latices such as the monodisperse polystyrenes. In the following section we present some recent results obtained with our HDC system using several, monodisperse standards and various surfactant conditions. [Pg.3]

The method using GC/MS with selected ion monitoring (SIM) in the electron ionization (El) mode can determine concentrations of alachlor, acetochlor, and metolachlor and other major corn herbicides in raw and finished surface water and groundwater samples. This GC/MS method eliminates interferences and provides similar sensitivity and superior specificity compared with conventional methods such as GC/ECD or GC/NPD, eliminating the need for a confirmatory method by collection of data on numerous ions simultaneously. If there are interferences with the quantitation ion, a confirmation ion is substituted for quantitation purposes. Deuterated analogs of each analyte may be used as internal standards, which compensate for matrix effects and allow for the correction of losses that occur during the analytical procedure. A known amount of the deuterium-labeled compound, which is an ideal internal standard because its chemical and physical properties are essentially identical with those of the unlabeled compound, is carried through the analytical procedure. SPE is required to concentrate the water samples before analysis to determine concentrations reliably at or below 0.05 qg (ppb) and to recover/extract the various analytes from the water samples into a suitable solvent for GC analysis. [Pg.349]

FIG. 6 Dependence of the square root of the SHG intensity ( I(2a>)) for membrane 2 without KTpCIPB (a) with KTpCIPB (b) on K+ ion concentrations in the adjacent aqueous solution containing KCl (O) and KSCN ( ), respectively. Inset The corresponding observed EMF to KCl and KSCN. The concentrations of ionophore 2 and KTpCIPB were 3.0 X 10 M and 1.0 x 10 M, respectively for both SHG and EMF measurements. The data points present averages for three sets of measurements. Error bars show standard deviations. (From Ref. 15.)... [Pg.449]

Spinels. There are limited experimental data on uranium and thorium partitioning between magnetite and melt (Nielsen et al. 1994 Blundy and Brooker 2003). Both studies find U and Th to be moderately incompatible. Blundy and Brooker s results for a hydrous dacitic melt at 1 GPa and 1025°C give Du and D h. of approximately 0.004. The accuracy of these values is compromised by the very low concentrations in the crystals and the lack of suitable SIMS secondary standards for these elements in oxide minerals. Nonetheless, these values are within the range of Djh of magnetites at atmospheric pressure 0.003-0.025 (Nielsen et al. 1994). It is difficult to place these values within the context of the lattice strain model, firstly because there are so few systematic experimental studies of trace element partitioning into oxides and secondly because of the compositional diversity of the spinels and their complex intersite cation ordering. [Pg.112]

The 50.31 MHz 13C NMR spectra of the chlorinated alkanes were recorded on a Varian XL-200 NMR spectrometer. The temperature for all measurements was 50 ° C. It was necessary to record 10 scans at each sampling point as the reduction proceeded. A delay of 30 s was employed between each scan. In order to verify the quantitative nature of the NMR data, carbon-13 Tj data were recorded for all materials using the standard 1800 - r -90 ° inversion-recovery sequence. Relaxation data were obtained on (n-Bu)3SnH, (n-Bu)3SnCl, DCP, TCH, pentane, and heptane under the same solvent and temperature conditions used in the reduction experiments. In addition, relaxation measurements were carried out on partially reduced (70%) samples of DCP and TCH in order to obtain T data on 2-chloropentane, 2,4-dichloroheptane, 2,6-dichloroheptane, 4-chloroheptane, and 2-chloroheptane. The results of these measurements are presented in Table II. In the NMR analysis of the chloroalkane reductions, we measured the intensity of carbon nuclei with T values such that a delay time of 30 s represents at least 3 Tj. The only exception to this is heptane where the shortest T[ is 12.3 s (delay = 2.5 ). However, the error generated would be less than 10%, and, in addition, heptane concentration can also be obtained by product difference measurements in the TCH reduction. Measurements of the nuclear Overhauser enhancement (NOE) for carbon nuclei in the model compounds indicate uniform and full enhancements for those nuclei used in the quantitative measurements. Table II also contains the chemical... [Pg.360]

Evaluation of the developed red color, using a spectrophotometer and a standard transmittance-concentration curve from data on known amounts of purified 118-phenyldihydrotriazole. [Pg.191]

Data on surface radium concentrations has been compiled for 394 of the 474 quadrangles covering the conterminous 48 states. The resulting distribution is illustrated in Figure 2, where the parameters shown for the distribution are calculated from the binned data. This distribution has a GM of 25 Bq kg and geometric standard deviation (GSD) of 1.75. Based on this distribution, approximately 20% of the surface radium concentration data are above 40 Bq kg and 0.7% are above 100 Bq kg... [Pg.23]


See other pages where Standardization and data on concentrations is mentioned: [Pg.32]    [Pg.34]    [Pg.38]    [Pg.40]    [Pg.42]    [Pg.495]    [Pg.32]    [Pg.34]    [Pg.38]    [Pg.40]    [Pg.42]    [Pg.495]    [Pg.8]    [Pg.296]    [Pg.223]    [Pg.234]    [Pg.274]    [Pg.117]    [Pg.278]    [Pg.264]    [Pg.60]    [Pg.239]    [Pg.423]    [Pg.235]    [Pg.181]    [Pg.110]    [Pg.240]    [Pg.154]    [Pg.9]    [Pg.102]    [Pg.123]    [Pg.104]    [Pg.350]    [Pg.106]    [Pg.472]    [Pg.326]    [Pg.124]    [Pg.246]    [Pg.213]    [Pg.22]   


SEARCH



Concentration data

Concentration standard

Data standards

Standardized data

© 2024 chempedia.info