Differential refractometer

The latest trend is to smaller beads in smaller columns, as this saves eluent and shortens the time for a chromatographic analysis. This argument can be correct if only one suitable detector is used. However, these modern small columns are not optimal for a combination of detectors. So-called multiple detection is a combination of some detectors with different measurement principles (differential refractometer, spectral photometer, light-scattering detector, on-line viscometer) behind the last column, mostly in series, seldom in a branched ( parallel ) order. In this way, the tedious preparative fractionation of a polymer sample can often be avoided. [Pg.440]

X 0.75 cm) Ve i = 28 ml = 50 ml eluent 0.05 M NaCI flow rate 0.80 ml/min detection Optilab 903 interferometric differential refractometer applied sample mass/volume 200 /tl of 2-mg/ml aqueous solutions sum of individual chromatograms (theory —) and (theory/experimental) ratio (—) plotted for quantification of deviations in separation performance between narrow distributed samples and broad distributed samples. [Pg.495]

SEC measurements were made using a Waters Alliance 2690 separation module with a 410 differential refractometer. Typical chromatographic conditions were 30°C, a 0.5-ml/min flow rate, and a detector sensitivity at 4 with a sample injection volume of 80 fil, respectively, for a sample concentration of 0.075%. All or a combination of PEO standards at 0.05% concentration each were used to generate a linear first-order polynomial fit for each run throughout this work. Polymer Laboratories Caliber GPC/SEC software version 6.0 was used for all SEC collection, analysis, and molecular weight distribution overlays. [Pg.502]

A detector is used to determine when to initiate collection of the eluent by a fraction collector. A differential refractometer can be used if the polymer... [Pg.616]

The most widely used molecular weight characterization method has been GPC, which separates compounds based on hydrodynamic volume. State-of-the-art GPC instruments are equipped with a concentration detector (e.g., differential refractometer, UV, and/or IR) in combination with viscosity or light scattering. A viscosity detector provides in-line solution viscosity data at each elution volume, which in combination with a concentration measurement can be converted to specific viscosity. Since the polymer concentration at each elution volume is quite dilute, the specific viscosity is considered a reasonable approximation for the dilute solution s intrinsic viscosity. The plot of log[r]]M versus elution volume (where [) ] is the intrinsic viscosity) provides a universal calibration curve from which absolute molecular weights of a variety of polymers can be obtained. Unfortunately, many reported analyses for phenolic oligomers and resins are simply based on polystyrene standards and only provide relative molecular weights instead of absolute numbers. [Pg.385]

Hie hydrolytic depolymerization of nylon-6 was followed by gel permeation chromatography (GPC), viscometry, and gravimetry. GPC determinations were performed on a Waters 150C chromatography system using benzyl alcohol as die eluant, two Plgel 10-p.m crosslinked polystyrene columns, and a differential refractometer detector. The flow rate was 1 mL/min. The concentration of the polymer solutions was 0.5 wt% and dissolution was accomplished at 130°C. [Pg.555]

For detection and quantitative determination a differential refractometer can generally be used. The detection limit is about 10 pg/ml. If only alkylphenol ether carboxylates are to be determined, a UV spectrophotometer can also be used whereby the detection limit is lowered to about 0.1 pg/ml. [Pg.348]

The differential refractometer monitors the deflection of a light beam caused by the difference in refractive index between the contents of the sample cell and those of the reference cell. A beam of light from an... [Pg.184]

Gel Permeation Chromatography. The instrument used for GPC analysis was a Waters Associates Model ALC - 201 gel permeation chromatograph equipped with a R401 differential refractometer. For population density determination, polystyrene powder was dissolved in tetrahydrofuran (THF), 75 mg of polystyrene to SO ml THF. Three y -styragel columns of 10, 10, 10 A were used. Effluent flow rate was set at 2.2 ml/min. Total cumulative molar concentration and population density distribution of polymeric species were obtained from the observed chromatogram using the computer program developed by Timm and Rachow (16). [Pg.382]

The variable quantities in the K term, i.e. rig, (AnMcf, and X, must be determined. Values of are available for most solvents from the literature X is obtained by dividing the value of X by the refractive index of the solution. The refractive index increment, (dn/dcj, must be determined to within 10 in dn using a differential refractometer. The choice of solvent is limited if dn/dc = 0, there is no scattering if dn/dc is greater than 0.3 cm g the Rayleigh ratio is no longer proportional to (dn/dc). ... [Pg.88]

The second most widely used detector in HPLC is the differential refractometer (RI). Being a bulk property detector, the RI responds to all substances. As noted in Table 3 the detection limits are several orders of magnitude higher than obtained with the UV detector. Thus, one turns to the RI detector in those cases in which substances are non-UV active, e.g. lipids, prostaglandins. In addition, the RI detector finds use in preparative scale operation. Finally, relative to the UV detector, the RI is significantly more temperature and flow sensitive and cannot be used in gradient elution. [Pg.235]

At the moment, one recommends to determine the molecular characteristics of pectins using SEC chromatography equipped with a differential refractometer, a multiangle laser light scattering detector and a viscometer as previously described [25]. This technique needs no calibration with the usual molecular weight standards such dextrans and pullulans... [Pg.23]

An ultraviolet absorption detector was used In tandem with a differential refractometer detector to obtain chemical composition data (3, 5 6). [Pg.77]

Figure 2. Chromatograms of AN/MA graft polymer (differential refractometer detector (a) 7% total solids (b) 11% total solids (c) 27% total solids)... Figure 2. Chromatograms of AN/MA graft polymer (differential refractometer detector (a) 7% total solids (b) 11% total solids (c) 27% total solids)...
The average value of the refractive index increment as determined using a Brice-Phoenix differential refractometer was (dn/dc) =... [Pg.242]

The apparatus employed for this study was a Waters Associates Model ALC/GPC 300 with a differential refractometer as mass detector operated at room temperature. A 2 ml sample loop with polymer concentrations of 0.01-0.1 wt.% cUid a 5 ml siphon were employed with mobile phase flowrates in the reuige 1-8 ml/min. [Pg.268]

Colin, H., Jaulmes, A. Guichon, G., Corno, J., and Simon, J, Construction and performance of an improved differential refractometer detector for liquid chromatography, J. Chromatogr. Sci., 17, 485, 1979. [Pg.53]

The output signal of concentration-sensitive detectors is proportional to the concentration or weight of polymer in the column eluent. Examples of this type include the differential refractometer and the ultraviolet-visible spectrophotometer. Infrared and fluorescence detectors are used infrequently. None of the detectors described above is truly universal i.e., the response of these detectors varies with the chemical species, and, in case of the DRI, response is also a function of the chromatographic eluent.156 Recently, an... [Pg.339]

Differential refractive index detectors measure the difference in refractive index between the solvent and the eluting polymer solution. The DRI can be used with almost any polymer-solvent combination, as long as the incremental increase in refractive index of the polymer solution with increase in polymer concentration is sufficient. Although a large number of differential refractometers are available in the market,167168 they usually conform to three main types, namely... [Pg.341]

CMC-3 Ultrahydrogel Linear and Ultrahydrogel 120 Waters , 0.15 M sodium phosphate buffer, pH 7.2 Differential refractometer... [Pg.356]


See other pages where Differential refractometer is mentioned: [Pg.27]    [Pg.693]    [Pg.360]    [Pg.431]    [Pg.413]    [Pg.355]    [Pg.362]    [Pg.433]    [Pg.441]    [Pg.613]    [Pg.5]    [Pg.2]    [Pg.679]    [Pg.4]    [Pg.78]    [Pg.93]    [Pg.188]    [Pg.193]    [Pg.208]    [Pg.227]    [Pg.317]    [Pg.323]    [Pg.566]    [Pg.315]    [Pg.341]    [Pg.343]    [Pg.343]    [Pg.355]   