Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sewer connection

When considering taxes, all types need to be considered initial fees, capital value, corporate rate, personal income tax, sales tax, property tax, unemployment insurance, workmen s compensation, and nuisance tax. During the constmction phase, several types of taxes may be levied. These include building permits, special fees, assessments, and sewer connection fees. [Pg.88]

Local Site Condition Evaluation. In addition to visiting the site, drawing up a contour map and geology reports, acquiring sod-bearing information, and a knowledge of boundaries, setbacks, local requirements, utdity tie-in locations, sewer connections, access to roadways, pipelines, radroads, etc, may be needed to make a fliU assessment. [Pg.88]

The ease of access to utilities should also help determine the laboratory s location. Most laboratories will need hot and cold water, electric power, gas, and sewer connection. The cost of bringing these to a remote location may be high. The sewer is often the most problematic. Many a concrete slab has been tom up at considerable expense in order to install a laboratory sewer. A building professional should be consulted to give advice in such cases. [Pg.16]

A typical laboratory will require a variety of common utilities, such as water, gas, and electric power. There must also be sewer connections and adequate provision for ventilation, as well as means for heating and cooling the area. In addition, there are often special laboratory needs, such as compressed air and vacuum. [Pg.27]

About 4000 years ago the city of Moenjo-Daro perished. It was one of the first modern cities and was situated in the Indus valley, approximately 5000 km north of the present Karatchi in Pakistan. The city was very advanced. Its houses were made of weather-proof bricks and the bathrooms inside had water-proof tiling. There were even open, brick sewers connected to the drains of the houses. [Pg.205]

The truth is that there have been major improvements in the water quality but not because of Mayor Vineyard specifically, if at all. The island has been working for 30 years to correct this problem. Federal regulation prompted the abatement of many combined sewer overflows as well as illegal sewer connections. The island improved the wastewater treatment facilities to stop primary effluent escaping the system. All of these continued while Mayor Vineyard was in office, but the relevant legislation was passed by prior administrations. If fact. Mayor Vineyard pulled some of the funding for research and diverted it to her limo service. [Pg.887]

Cleanliness is especially necessary in the case of the yeast and fermenting tubs, where the intrusion of these organisms will cause serious trouble. The walls of the distillery should be kept free from mold by an occasional coat of whitewash. The floors should be flooded daily, and the sewer connections must be adequate to remove the water and other wastes from the premises. [Pg.29]

A sewer connection for a new housing estate is to be made in an existing 4 m deep manhole. The manhole is 2 m from the kerbside on a 40 mph single carriageway road. The road opening notice specifies that the work must be carried out only between the hours of 9.30 am and 4.30 pm. [Pg.154]

Even where not obvious from the type of work being done, such as a sewer connection, an excavation should be considered as a potential confined space where the oxygen supply may be limited and fumes may collect. Where there is any possibility of this occurring, such as in deep excavations or those in boggy areas, the atmosphere should be tested by a competent person using a proprietary meter, and regular checks must be maintained to ensure that the position does not change. [Pg.159]

A sewer connection or drain is not required, unless a special hazard is posed by the water. [Pg.125]

Q Sewer connection or drain not required unless special hazards noted. [Pg.409]

In order to encourage complete recycling Edo authorities ordered payments for the removed night soil see Tanaka, Y. 1998. The cyclical sensibility of Edo-period Japan. Japan Echo 25(2) 12-16. This arrangement had persisted for more than three centuries most of the inhabitants in even the largest Japanese cities received sewer connections only after 1970. [Pg.262]

House Sewer The pipeline connecting the house and drain and the septic tank. [Pg.616]

Infiltration The seepage of groundwater into a sewer system, including service connections. Seepage frequently occurs through defective or cracked pipes, pipe joints, connections or manhole walls. [Pg.616]

If the drum may occasionally receive water, caustic or similar aqueous streams, which would create problems in receiving facilities if pumped out with the hydrocarbon, then means of separate drainage should be be included. This may consist of a connection to the sewer from the bottom of the boot or in the case of sour water, a connection off the pumpout pump discharge routed to sour water facilities or other suitable disposal. [Pg.233]

In some cases, it is possible to combine the functions of blowdown and disengaging drums in one vessel. However, PR devices discharging liquid hydrocarbons lighter than pentane should not be connected into the drum if there is a possibility that such liquids could accumulate and be released to the sewer through the seal leg. Also, the drum vent should be sized to prevent pressure buildup due to vaporization. In these applications, the design criteria for both services must be met and special attention should be paid to potential hazards and problems which may be introduced, such as ... [Pg.243]

As just implied, the land-based phosphorus cycle is connected to the water-based cycle via the rivers and sewers. It has been estimated that, on a global scale, about 2 million... [Pg.478]

Minimum capacity of 27001 to be provided. Subject to local authority approval, the effluent output from a septic tank may be connected to an adopted sewer subject to quality of output and size and location of drainage. [Pg.28]

A typical scale for such drawings is V4 inch to the foot, but any convenient scale may be used. On the drawing, all existing details—doors, windows, wall protrusions (common in the popular tilt-up construction), pipes and conduit on the walls, sewer outlets, utility connections, etc.—should be noted. It is important that all details be accurately recorded. [Pg.19]

Good housekeeping Keep toxicants and dusts contained. Use dikes around tanks and pumps. Provide water and steam connections for area washing. Provide lines for flushing and cleaning. Provide well-designed sewer system with emergency containment. [Pg.95]

A sewer network and any corresponding treatment have traditionally been separately designed and operated. Two different and separate functions have been dealt with the sewer system must collect and convey the wastewater to the treatment plant, and the treatment plant must reduce pollution load into the receiving water according to the quality standards set. Consequently, sewers are often just considered input systems at the boundaries where they are connected with wastewater treatment plants and overflow structures that discharge untreated wastewater into watercourses during rainfall. This traditional approach to sewer performance needs considerable improvement. [Pg.9]

A process oily water sewer system is a convenient location to direct oily wastes. The oily water system normally collects into a sump. If several lines connect into a common header, care should be taken to prevent backflow into another outlet source. In such cases use of an air gap, i.e., drainage in to a collection ftinnel has be advantageous. [Pg.140]

No vault containing hydrogen gas piping shall be connected by means of a drain connection to any other substructure, such as a sewer. [Pg.161]


See other pages where Sewer connection is mentioned: [Pg.21]    [Pg.31]    [Pg.107]    [Pg.53]    [Pg.619]    [Pg.21]    [Pg.31]    [Pg.107]    [Pg.53]    [Pg.619]    [Pg.441]    [Pg.220]    [Pg.221]    [Pg.222]    [Pg.224]    [Pg.224]    [Pg.242]    [Pg.276]    [Pg.63]    [Pg.99]    [Pg.22]    [Pg.31]    [Pg.398]    [Pg.245]    [Pg.104]    [Pg.105]    [Pg.77]    [Pg.184]   
See also in sourсe #XX -- [ Pg.31 ]




SEARCH



Sewers

© 2024 chempedia.info