Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sampling for quality control

Example 1 Sample Quantity for Composition Quality Control Testing An example is sampling for quality control of a 1,000 metric ton (VFg) trainload of-Ks in (9.4 mm) nominal top-size bentonite. The specification requires silica to be determined with an accuracy of plus or minus three percent for two standard errors (s.e.). With one s.e. of 1.5 percent, V is 0.000225 (one s.e. weight fraction of 0.015 squared). The problem to be solved is thus calculating weight of sample to determine sihca with the specified error variance. [Pg.1757]

This reasonably low viscosity premix can be prepared in rather large batches which are sampled for quality control of ingredient proportions. [Pg.898]

Quality control ( f Submission of samples for quality control... [Pg.21]

Submission of samples for quality control SDQCI/QCI (performance of the QC procedures and sends the results to PC) 3-5 Months... [Pg.785]

The fourth means of avoiding contamination from personnel sources is by localized protection of critical operations that necessitate manual intervention. This includes point of All and other operations like connecting and disconnecting feed lines, loading rubber plugs into hoppers, taking samples for quality control checks, etc. The issue to address in connection with localized protection is the extent to which it should be applied. There are two methods (a) total containment in an isolator or glove-box, and (b) protection by means of laminar Aow Altered air. [Pg.189]

Coaxial push-out tests (DIN 53769-A) are typically performed on production run pipe samples for quality-control purposes. Typical results using oxyfluorinated HDPE as liner material are shown in Table 16.11 below. [Pg.253]

Complex environmental samples originate from diverse matrices (the predominant material of which the sample to be analyzed is composed). These matrices, usually either water or soil/sediment, can contain as many as 50 to 100 organic components at widely varying concentrations. The EPA approach to the analysis of these samples involves the analysis of specific (or target) compounds and the use of authentic standards for quality control. The current number of standards in the EPA repository is about 1500, and their analysis is covered by various approved methods. [Pg.295]

Repetitive routine analysis of a specific sample (e.g., for Quality Control) will usually require a dedicated instrument. Therefore, the chromatograph and, in particular, the detector will be chosen for that specific analysis. Consequently, only one detector will be necessary and the purchase of an armory of detectors on the basis that they might be needed in the nebulous future is not advised. An alternative detector can always be obtained if and when the demand arises. The same argument applies to multi-solvent reservoirs and multi-solvent gradient programmers and other accessories that are not immediately required for the specific analysis in mind. [Pg.151]

Over the twentieth century, the mbber industry has developed special rheometers, essentially factory floor instmments either for checking process regularity or for quality control purposes, for instance, the well-known Mooney rheometer (1931), the oscillating disk rheometer (1962), and the rotorless rheometer (1976). All those instmments basically perform simple drag flow measurements but they share a common feature During the test, the sample is maintained in a closed cavity, under pressure, a practice intuitively considered essential for avoiding any wall slip effects. Indeed it has... [Pg.818]

All the analytical methods mentioned to separate, identify, and quantify chlorophylls and derivatives consume time, money, and samples. As alternatives, industries have been employing non-destructive methods for surface color measurements that are not only indirectly related to chlorophyll content, but may also estimate the pigments directly in tissues, leaving the sample intact and enabling serial analyses in a relatively short time. Eood color affects consumer acceptance and is an important criterion for quality control. Color vision is a complex phenomenon that depends on both the total content and number of pigments and also on absorption, reflectance and emission spectra of each compound present. [Pg.441]

Using these rhelogical methods laboratories for quality control and research and development have good tools to characterize pectins in gels and solutions. The most important points are the reproducable handling, pretreatment, and measurement of the samples and the knowledge which information can be derived from the measured data regarding the texture, the production parameters, and the sensory evaluation of the product. [Pg.422]

Solution viscosity measurements have sometimes been utilized as qioality control tests for this polymer. Chromatographs of three samples that showed Identical intrinsic viscosities (0.8 g/dl) in toluene are shown in Figure 9. These chromatographs indicate that the identical viscosities are the result of different combinations of high and low MW components. These three polymer samples probably have significantly different physical properties and if viscosity measurments alone are utilized for quality control purposes, they may be quite misleading. [Pg.263]

P.C. Thijssen, S.M. Wolfrum, G. Kateman and H.C. Smit, A Kalman filter for calibration,eval-uation of unknown samples and quality control in drifting systems Part 1. Theory and simulations. Anal. Chim. Acta, 156 (1984) 87-101. [Pg.603]

Assume that without the proper use of reference samples in an exploration program, a site is purchased that is in fact barren. Hill (1974), for example, cites a 20 % added analytical cost for quality control and quality assurance. He further cites a possible cost of 220 million for purchasing and developing a mine site. The analytical expense for QA QC based on use of reference samples is trivial in comparison to the potential loss, if the analyses of exploration survey samples are faulty and the mine worthless as a result. [Pg.227]

Applications Specific applications of the direct spectrometric analysis methods of solid samples of Table 8.36 are given under the specific headings. One investigation that is practically only possible by direct solids analysis is checking the homogeneity of polymers [136,137] this is of significance for reference materials and for quality control. A method for the assessment of microhomogeneity should meet various requirements [223] ... [Pg.627]

Applications ICP-MS has become the technique of choice for the determination of elements in a wide range of liquid samples at concentrations in the ng L 1 to [igL-1 range. Typical applications of ICP-MS are multi-element analysis of liquids (even with high solid contents) element speciation by hyphenation to chromatographic techniques continuous on-line gas analysis multi-element trace analysis of polymers and trace analysis in high-purity materials. ICP-MS is routinely used for quality control purposes. [Pg.658]

GFAAS end analysis of Pb in blood was critically discussed in a review, including methods of introducing the sample into the furnace, matrix interferences and ways of improving the precision of the method, such as use of a stabilized temperature platform40. An evaluation program was carried out for quality control materials and proficiency for... [Pg.434]

Good quality control procedures are crucial to allowing the results of this project to integrated year upon year. More than 10% of all samples analyzed are for quality control. About half of these are duplicates the others are blanks, certified or internal reference standards and spiked samples. [Pg.92]

For every batch of 20-30 samples a quality control reference material is analysed - either NIST SRM 2711 or CYP-A. [Pg.504]


See other pages where Sampling for quality control is mentioned: [Pg.130]    [Pg.285]    [Pg.509]    [Pg.253]    [Pg.193]    [Pg.3]    [Pg.130]    [Pg.285]    [Pg.509]    [Pg.253]    [Pg.193]    [Pg.3]    [Pg.1642]    [Pg.202]    [Pg.408]    [Pg.251]    [Pg.359]    [Pg.362]    [Pg.279]    [Pg.218]    [Pg.108]    [Pg.34]    [Pg.28]    [Pg.357]    [Pg.267]    [Pg.313]    [Pg.332]    [Pg.666]    [Pg.704]    [Pg.74]    [Pg.90]    [Pg.3]    [Pg.34]   
See also in sourсe #XX -- [ Pg.534 , Pg.758 ]




SEARCH



Control sample

Quality Control samples

Quality control, sampling

Sampling Quality

Sampling controller

© 2024 chempedia.info