Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Polycyclic aromatic hydrocarbon complex

Many fluorescence sensors are based, not on direct fluorescence, but on the quenching of fluorescence. Molecular oxygen, for example, is one of the best col-lisional quenchers. Oxygen can quench the fluorescence from polycyclic aromatic hydrocarbons complexes of ruthenium, osmium, iridium, and platinum and a number of surface-adsorbed heterocyclic molecules. An oxygen sensor can be made by immobilizing the fluorophore in a thin layer of silicone on the end of a fiber-optic bundle. Sensors for SO-, haliilcs, H-O-, and several other molecules have been ba.sed on fluorescence quenching. [Pg.417]

An appreciation of the extent to which invertebrate species may be exposed to such chemicals comes from considering the effects of complex mixtures. In the North Atlantic ecosystem alone, hundreds of pollutant chemicals have been identified. These include metals, synthetic and chlorinated organics and polycyclic aromatic hydrocarbons. Over 300 aromatic hydrocarbons have been detected in some regions of the Chesapeake Bay, and high concentrations of PCBs have been... [Pg.52]

The polycyclic aromatic hydrocarbons such as naphthalene, anthracene, and phenan-threne undergo electrophilic aromatic substitution and are generally more reactive than benzene. One reason is that the activation energy for formation of the c-complex is lower than for benzene because more of the initial resonance stabilization is retained in intermediates that have a fused benzene ring. [Pg.568]

Polycyclic aromatic hydrocarbons, indole and quinoline derivatives, naphthylamines, azulenes Silica gel G Formation of oxidation products via the initially formed iodine complexes [15]... [Pg.147]

Polycyclic aromatic hydrocarbons Silica gel G Monovalent oxidation of the iodine complexes via radical cations yields dimeric or tetrameric aromatics [16]... [Pg.147]

Because process mixtures are complex, specialized detectors may substitute for separation efficiency. One specialized detector is the array amperometric detector, which allows selective detection of electrochemically active compounds.23 Electrochemical array detectors are discussed in greater detail in Chapter 5. Many pharmaceutical compounds are chiral, so a detector capable of determining optical purity would be extremely useful in monitoring synthetic reactions. A double-beam circular dichroism detector using a laser as the source was used for the selective detection of chiral cobalt compounds.24 The double-beam, single-source construction reduces the limitations of flicker noise. Chemiluminescence of an ozonized mixture was used as the principle for a sulfur-selective detector used to analyze pesticides, proteins, and blood thiols from rat plasma.25 Chemiluminescence using bis (2,4, 6-trichlorophenyl) oxalate was used for the selective detection of catalytically reduced nitrated polycyclic aromatic hydrocarbons from diesel exhaust.26... [Pg.93]

Ma J, Horii Y, Cheng J, Wang W, Wu Q, Ohura T, Kannan K (2009) Chlorinated and parent polycyclic aromatic hydrocarbons in environmental samples from an electronic waste recycling facility and a chemical industrial complex in China. Environ Sci Technol 43(3) 643-649. doi 10.1021/es802878w... [Pg.309]

Chemicals degraded by WRF include pesticides such as organochlorines DDT and its very toxic metabolite DDE [8, 9] and organophosphate pesticides such as chlorpyrifos, fonofos and terbufos [10] polychlorinated biphenyls (PCBs) of different degrees of chlorine substitution [11-13], some even to mineralization [14, 15] diverse polycyclic aromatic hydrocarbons (PAHs) in liquid media and from contaminated soils or in complex mixtures such as creosote [16-18] components of munition wastes including TNT and its metabolites DNT [19-23], nitroglycerin [24] and RDX [25]. [Pg.140]

Human exposure to complex mixtures of polycyclic aromatic hydrocarbons (PAH) occurs through inhalation of tobacco smoke and polluted indoor or outdoor air, through ingestion of certain foods and polluted water, and by dermal contact with soots, tars, and oils CO. Methylated PAH are always components of these mixtures and in some cases, as in tobacco smoke and in emissions from certain fuel processes, their concentrations can be in the same range as some unsubstituted PAH. The estimated emission of methylated PAH from mobile sources in the U.S. in 1979 was approximately 1700 metric tons (2). The occurrence of methylated and unsubstituted PAH has been recently reviewed (1, 2). In addition to their environmental occurrence, methylated PAH are among the most important model compounds in experimental carcinogenesis. 7,12-Dimethylbenz[a]anthracene, one of... [Pg.91]

In complex organic molecules calculations of the geometry of excited states and hence predictions of chemiluminescent reactions are very difficult however, as is well known, in polycyclic aromatic hydrocarbons there are relatively small differences in the configurations of the ground state and the excited state. Moreover, the chemiluminescence produced by the reaction of aromatic hydrocarbon radical anions and radical cations is due to simple one-electron transfer reactions, especially in cases where both radical ions are derived from the same aromatic hydrocarbon, as in the reaction between 9.10-diphenyl anthracene radical cation and anion. More complex are radical ion chemiluminescence reactions involving radical ions of different parent compounds, such as the couple naphthalene radical anion/Wurster s blue (see Section VIII. B.). [Pg.69]

The NO + 03 chemiluminescent reaction [Reactions (1-3)] is utilized in two commercially available GC detectors, the TEA detector, manufactured by Thermal Electric Corporation (Saddle Brook, NJ), and two nitrogen-selective detectors, manufactured by Thermal Electric Corporation and Antek Instruments, respectively. The TEA detector provides a highly sensitive and selective means of analyzing samples for A-nitrosamines, many of which are known carcinogens. These compounds can be found in such diverse matrices as foods, cosmetics, tobacco products, and environmental samples of soil and water. The TEA detector can also be used to quantify nitroaromatics. This class of compounds includes many explosives and various reactive intermediates used in the chemical industry [121]. Several nitroaromatics are known carcinogens, and are found as environmental contaminants. They have been repeatedly identified in organic aerosol particles, formed from the reaction of polycyclic aromatic hydrocarbons with atmospheric nitric acid at the particle surface [122-124], The TEA detector is extremely selective, which aids analyses in complex matrices, but also severely limits the number of potential applications for the detector [125-127],... [Pg.381]

Peroxyoxalate-based CL reactions are related to the hydrogen peroxide oxidation of an aryl oxalate ester, producing a high-energy intermediate. This intermediate (l,2-dioxetane-3,4-dione) forms, in the presence of a fluorophore, a charge transfer complex that dissociates to yield an excited-state fluorophore, which then emits. This type of CL reaction can be used to determine hydrogen peroxide or fluorophores including polycyclic aromatic hydrocarbons, dansyl- or fluores-camine-labeled analytes, or, indirectly, nonfluorescers that are easily oxidized (e.g., sulfite, nitrite) and quench the emission. The most widely used oxalate... [Pg.435]

The alteration of hemoprotein(s) P-450 subpopulations in the rat may be observed spectrally, because after treatment of rats with polycyclic aromatic hydrocarbons, the Soret maximum of the carbonmonoxyferrocytochrome complex undergoes a hypsochromic shift from 450 to 448nm (50). This blue shift was not seen with rainbow trout hepatic microsomes (29,30). However, this does not preclude the induction of novel hemoproteins P-450 since (a) the induced hemoprotein(s) maty not differ spectrally from the constitutive enzymes and (b) the induced-hemoprotein may account for only a small proportion of total hemoprotein P-450, and hence its contribution to the position of the Soret maximum of carbon monoxide-treated reduced microsomes may be negligible. The latter suggestion is supported by the work of Bend et al. with the little skate. These workers have shown that hepatic microsomes from 1, 2,3,4-dibenzanthracene treated skates did not exhibit a hypsochromic shift when compared to control microsomes, however, partially purified hemoprotein exhibited an absorbance maxima at 448 nm (51). [Pg.326]

Hase A, Lin PH, Hites RA. 1976. Analysis of complex polycyclic aromatic hydrocarbon mixtures by computerized GC-MS. lu Ereudeuthal R, Joues PW, eds. Carciuogeuesis A compreheusive survey. Volume 1 Polyuuclear aromatic hydrocarbou chemistry, metabolites, aud carciuogeuesis. New York, NY Raveu Press, 435-442. [Pg.179]


See other pages where Polycyclic aromatic hydrocarbon complex is mentioned: [Pg.891]    [Pg.44]    [Pg.9]    [Pg.199]    [Pg.4]    [Pg.7]    [Pg.279]    [Pg.7]    [Pg.8]    [Pg.8]    [Pg.9]    [Pg.10]    [Pg.12]    [Pg.220]    [Pg.231]    [Pg.128]    [Pg.160]    [Pg.133]    [Pg.31]    [Pg.108]    [Pg.762]    [Pg.186]    [Pg.326]    [Pg.83]    [Pg.378]    [Pg.236]    [Pg.289]    [Pg.157]    [Pg.20]    [Pg.187]    [Pg.27]    [Pg.113]   
See also in sourсe #XX -- [ Pg.74 , Pg.75 ]




SEARCH



Aromatic complexes

Aromaticity polycyclic aromatic hydrocarbons

Aromatics complex

Aromatics complexation

Complexation aromatic hydrocarbons

Hydrocarbons complexes

Polycyclic hydrocarbons aromatic

© 2024 chempedia.info