Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Service water

Cooling water service failure 3. Same 3. Check and monitor reliability of water DAC 2/93... [Pg.472]

Titanium for industrial Brine and Sea Water Service, Titanium Metal Corporation of America, Denver, Colo., 1968. [Pg.112]

The principal U.S. manufacturers and/or water service companies that sold or leased chlorine dioxide generating equipment and services in 1991 were Aquatec, Capital Controls, Chemquip, Drew Chemical (Division of Ashland Chemical), Eischer Porter, Prominent Eluid Controls, Rio Linda, and Wallace Tiernan. [Pg.488]

Aluminum alloy (and in particular alclad aluminum) tubing is sometimes used in water service. The alclad alloy has a sacrificial aluminum-alloy layer metallurgically bonded to a core alloy. [Pg.1073]

A paper mill was using an ANSI end suction process pump with clear water service. The motor was designed properly. The pump axial thrust bearing ran hot, failing after three months of operation. It was replaced with an identical bearing. This ran during three months and also failed. All pump components were investigated and found that they complied with the specifications. These facts eliminated the defects of materials as a cause. [Pg.228]

The polyacetals have a good record of performance in uses involving hot air and hot water. Plumbing components have been used for hot water service in the range 60-80°C and applications in hot air well in excess of 90°C. Recommended maximum continuous use temperatures are given in Table 19.4... [Pg.542]

DISCHARGE CONSENTS PeiTuission to discharge trade effluent directly into controlled waters is given by the National Rivers Authority in the form of a discharge consent which will specify amounts and conditions. Discharges to public sewers are controlled by discharge consents by one of the ten Water Service Companies. [Pg.13]

Design of hot and cold water services to avoid water standing undisturbed for long periods. Use of covered tanks and cisterns with approved fittings and materials. [Pg.406]

The company was founded in 1991 and started its activities in 1996 when Esko Tahti became its managing director. TAKE s scope of activities includes the whole area of building services. Us other major projeas have been in the area o( energy use in buildings, life cycle economy, water services, indoor air control, clustering, and IT technologies and automation. [Pg.1550]

Butterfly valves are particularly useful in low-pressure produced water service and as gas throttling valves on the inlets of compressors. [Pg.432]

From tire National Joint Health mid Safety Committee for Water Service. ... [Pg.277]

National Joint Health and Safety Committee for Water Service, Safety Aspects of Storage, Handling and Use of Chlorine and Sulfur Dioxide, London. April 1982. [Pg.284]

Assume that a boiler feed water is being pumped at 180 °F. Read the chart in Figure 3-46 and the water vapor pressure curve, and follow over to read NPSH reduction = 0.45 feet. A pump selected for the sertice requires 6 feet cold water service NPSHr ... [Pg.194]

Range the temperature difference between the warm water into the tower and the cold water out. The range determines the heat load on the tower, which in turn reflects the requirements of the cooling water service. The... [Pg.382]

Process refrigeration is used at many different temperature levels to condense or cool gases, vapors, or liquids. Refrigeration is necessary when the process requires cooling to a temperature not reliably available from the usual water service or other coolant source, includingjoule-Thompson, or polytropic expansion of natural gas or process system vapors. [Pg.289]

Provision of separate hot, cold and drinking water services for canteen facilities. [Pg.59]

Used mainly for refrigeration and cold-water services, also low-temperature tankage. When laminated to suitable facings is employed in building applications. [Pg.123]

These are used for hot water services with a maximum operating pressure of 5 bar and a maximum output in the order of 1500 kW. Site assembly of the unit is necessary and will consist of a bank of cast iron sections. Each section has internal waterways. [Pg.349]

Corrosion problems that arise are frequently discussed under the headings (a) sea-water, and (b) fresh waters, but there is, in fact, no sharp dividing line, since some harbour, estuarine and brackish well waters are mixtures of sea-water and fresh water and are often variable in composition. In the past, corrosion problems were serious, particularly in sea-water service, but resistant alloys have been developed and although trouble still occasionally arises this is more frequently due to poor design or operation rather than to lack of materials suitable for the application. [Pg.694]

The major uses of lead in the UK are in batteries, and in sheet and pipe of which the vast majority is sheet for building purposes. These applications account for about one third each of lead used. This situation is unique, since in all other countries batteries account for most of the lead market. A small but very important application is sheet and pipe for the chemical industry. Lead is no longer installed for water services. Lead cable sheathing which accounts for 5% is in general decline, but is valued in niche applications such as on oil rigs where resistance to hydrocarbons is important. The use of lead for anodes accounts for a very small tonnage, but is still of great importance to the industries which use them. [Pg.720]

BISRA tests on galvanised steel pipe buried for five years at five different sites are described by Hudson and Acock The galvanised pipes resisted corrosion rather better than steel at all sites. Galvanised pipes of small diameter are frequently used to provide underground water services in farms and similar establishments, and little trouble is experienced. [Pg.820]

Soil Galvanised pipe is frequently used for underground water services. Table 13.10 gives results of tests carried out with galvanised pipes and plates buried at different sites. [Pg.493]

Now the pump selected reads NPSHR on its pump performance curve of 12 feet for cold water service. [Pg.194]

Traditionally, the mix of pretreatment equipment required to meet a specific FW volume and quality specification is provided as a permanent installation under a capital project, although today there is a growing global market in outsourced water services. Typically, vendors such as Ecolochem, Inc., a world leader in this type of service, provide trailer-mounted, mobile water-processing equipment that can be... [Pg.305]

Looking further at the second group, although many of the larger, non-utility operators around the world retain a resident water services chemist or trained technician, there is a marked tendency for all owners or operators, whether large or small, to work in conjunction with a water treatment service company. There is also a common purpose to use branded BW treatment chemical products rather than commodities. [Pg.993]

Regular washer-type faucets are hard to control for low water flow, such as required by condensers. For these purposes, needle valves are recommended. They give excellent control, and flow rate does not change as long as the pressure remains constant. The inexpensive plug-type valves are rarely adequate for laboratory water service. [Pg.88]

The hot and cold water services in buildings have been identified as potential sources of Legionella proliferation. Whilst the risk of Legionella proliferation in such systems may be minimised by good system design, in practice it is found that many systems do not conform to the ideal and their redesign would be economically prohibitive.. [Pg.33]

The effectiveness of chlorine reduces markedly as the pH of the system water rises above 7 and at pH s above 8 is largely ineffective as a disinfectant. High levels of chlorine are also known to be aggressive to many of the materials of construction of water services. [Pg.33]

There is thus a requirement for a disinfection system which will assist in minimising the risk from Legionella in hot and cold water services without the problems associated with chlorination. [Pg.33]


See other pages where Service water is mentioned: [Pg.441]    [Pg.274]    [Pg.441]    [Pg.72]    [Pg.4]    [Pg.114]    [Pg.193]    [Pg.509]    [Pg.208]    [Pg.237]    [Pg.545]    [Pg.693]    [Pg.693]    [Pg.698]    [Pg.699]    [Pg.76]    [Pg.509]    [Pg.4]    [Pg.909]   
See also in sourсe #XX -- [ Pg.346 ]




SEARCH



Closed Cooling Water System for Reactor Service

Cooling Water Program Field Services

Service Clarified Water

Service Water System

The Phoenix Water Services Department Case Study

Water Treatment Services

Water service companies

Water, acid service

© 2024 chempedia.info