Analytical phase

Extraction Eiltering limits particulate gravimetry to solid particulate analytes that are easily separated from their matrix. Particulate gravimetry can be extended to the analysis of gas-phase analytes, solutes, and poorly filterable solids if the analyte can be extracted from its matrix with a suitable solvent. After extraction, the solvent can be evaporated and the mass of the extracted analyte determined. Alternatively, the analyte can be determined indirectly by measuring the change in a sample s mass after extracting the analyte. Solid-phase extractions, such as those described in Ghapter 7, also may be used. [Pg.263]

High ionisation efficiencies of vapour-phase analytes... [Pg.474]

The most important gas phase analytical techniques are mass spectrometry and gas phase chromatography. If the total gas pressure is <10-4-10-8 Torr, a mass spectrometer such an omegatron or a quadrupole instrument may be inserted into the reactant volume. However, in most cases, the pressure is in excess of this, and gas must be delivered to a mass spectrometer via a leak, such as a Metrosil pellet or a capillary constriction, situated as closely as possible to the reaction volume. [Pg.18]

Gundersen and Blomhoff (1999) used online dilution with online SPE to measure vitamin A (retinol) and other active retinoids in animal plasma. The intention of online dilution in this application was on optimizing SPE extraction conditions rather than on peak focusing during analytical separation. An SPE cartridge packed with Bondapak C18 materials (37 to 53 jt/M, 300 A, Waters, Milford, Massachusetts) and a reversed-phase analytical column (250 x 2.1 mm inner diameter, Superlex pkb-100, Supelco, Bellefonte, Pennsylvania) were controlled by a six-port switching valve (Rheodyne, Cotati,... [Pg.283]

Direct injection of plasma or supernatant after protein precipitation on a short column with a high liquid flow rate is a common method for reducing analysis time in the pharmaceutical industry. The direct injection of a sample matrix is also known as the dilute-and-shoot (DAS) approach.62 DAS can be applied to all types of matrices and approaches and is the simplest sample preparation method with matrix dependency. Direct injection can also be approached through the extraction of eluent from PPT, SPE, and LLE onto a normal phase analytical column. The procedure is called hydrophilic interaction liquid chromatography (HILIC)70110111 and it avoids the evaporation and reconstitution steps that may cause loss of samples from heat degradation and absorption. [Pg.329]

Gas-phase analytical methods, flash vacuum pyrolysis and, 21 139-140 Gas-phase decomposition, of Group III organometallics, 22 156 Gas-phase grown carbon fibers, 26 736-737 Gas-phase height of a transfer unit (HG), 1 51-52... [Pg.393]

The choice of carrier gas and gas flow control are critical for successful GC. The carrier gas does no more in the separation process than its name implies it carries the vapor phase analyte molecules along the column. As such, it must be inert, non-toxic, inexpensive, highly pure and must provide efficient transport with minimal band broadening. For packed column GC, nitrogen is the most commonly used carrier gas, followed by helium. For capillary column GC, the most common carrier gas is helium, followed by hydrogen and nitrogen. [Pg.459]

Chiral separations result from the formation of transient diastereomeric complexes between stationary phases, analytes, and mobile phases. Therefore, a column is the heart of chiral chromatography as in other forms of chromatography. Most chiral stationary phases designed for normal phase HPLC are also suitable for packed column SFC with the exception of protein-based chiral stationary phases. It was estimated that over 200 chiral stationary phases are commercially available [72]. Typical chiral stationary phases used in SFC include Pirkle-type, polysaccharide-based, inclusion-type, and cross-linked polymer-based phases. [Pg.221]

To leam that an approximate value of y can be calculated for solution-phase analytes by using the Debye-HUckel equations (equations (3.14) and (3.15)). [Pg.26]

The activity a and concentration c are related by a = (c/c ) x y (equation (3.12)), where y is the mean ionic activity coefficient, itself a function of the ionic strength /. Approximate values of y can be calculated for solution-phase analytes by using the Debye-Huckel relationships (equations (3.14) and (3.15)). The change of y with ionic strength can be a major cause of error in electroanalytical measurements, so it is advisable to buffer the ionic strength (preferably at a high value), e.g. with a total ionic strength adjustment buffer (TISAB). [Pg.82]

The potential of the working electrode is ramped at a scan rate of v. The resultant trace of current against potential is termed a voltamnu ram. In linear-sweep voltammetry (LSV), the potential of the working electrode is ramped from an initial potential Ei to a final potential Ef (cf. Figure 6.2). Figure 6.12 shows a linear-sweep voltammogram for the reduction of a solution-phase analyte, depicted as a function of scan rate. Note that the jc-axis is drawn as a function of overpotential (equation (6.1)), and that the peak occurs just after = 0. [Pg.156]

Heterogeneous A process occurring between phases, as for example, electron transfer between a solid electrode and a solution-phase analyte. [Pg.340]

Brede, C., Skjevrak, I. and Herikstad, H. (2003). Determination of primary aromatic amines in water food simulant using solid-phase analytical derivatization followed by gas chromatography coupled with mass spectrometry, J. Chrom. A, 983, 35-42. [Pg.331]

To collect a sample, the probe with a SPME fiber installed is inserted into the soil. Air is pumped through the probe, drawing subsurface soil vapors into the probe tip and across the SPME fiber. Pumping air across the fiber increases uptake of target analytes by the SPME fiber relative to what is collected by molecular diffusion alone. Once a sample is collected, the SPME fiber is removed from the probe for analysis. To analyze the sample, the SPME fiber is inserted into a modified inlet system attached to the Fido sensor. The modified inlet serves to heat the SPME fiber, causing rapid and quantitative desorption of trapped molecules of analyte. The vapor-phase analyte is then swept into the sensor for analysis by a flow of carrier gas. [Pg.169]

In 1985, Ruzicka and Hansen established the principles behind flow injection optosensing [13-15], which has subsequently been used for making reaction-rate measurements [16], pH measurements by means of immobilized indicators [17,18], enzyme assays [19], solid-phase analyte preconcentration by sorbent extraction [20] and even anion determinations by catalysed reduction of a solid phase [21] —all these applications are discussed in Chapters 3 and 4. Incorporation of a gas-diffusion membrane in this type of sensor results in substantially improved sensitivity (through preconcentration) and selectivity (through removal of non-volatile interferents). The first model sensor of this type was developed for the determination of ammonium [13] and later refined by Hansen et al. [22,23] for successful application to clinical samples. [Pg.271]

Horvath, C., Melander, W., Molnar, L, and Molnar, P., Enhancement of retention by ion-pair formation in liquid-chromatography with nonpolar stationary phases. Analytical Chemistry 49(14), 2295-2305, 1977. [Pg.92]

The equations reported above are related to MEKC and all other EKC separation modes performed with pseudostationary phase, analytes, and EOE moving in the same direction at different velocities. Such condition applies when the electroosmotic mobility is higher than the electrophoretic mobility of the pseudostationary phase migrating to the direction opposite to that of EOF. [Pg.193]

Column Detection Mobile phase Analytes Reference... [Pg.38]

C. Horvath, W. Melander and I. Molnar, Liquid chromatography of ionogenic substances with nonpolar stationary phases. Analytical Chemistry, 49 (1977) 142. [Pg.306]

An example of the minimum requirement for potency assay of the drug substance and drug product is tabulated in Table 4. Note that the postponement of intermediate precision is aligned with previous discussion that the use of early phase analytical method resides mainly in one laboratory and is used only by a very limited number of analysts. Each individual company s phased method validation procedures and processes will vary, but the overall philosophy is the same. The extent of and expectations from early phase method validation are lower than the requirements in the later stages of development. The validation exercise becomes larger and more detailed and collects a larger body of data to ensure that the method is robust and appropriate for use at the commercial site. [Pg.740]

In this equation, PLref represents the PL intensity in a reference ambient (typically, vacuum or nitrogen for gas phase analytes and pure solvent for solution analytes) PL ( represents the PL intensity in the presence of the analyte a = (a -I- P) is... [Pg.348]

Gas phase analyte ions from source with differing wiZ values... [Pg.139]

In chromatography there are at least three equilibria analyte/mobile phase, analyte/stationary phase and mobile phase/stationary phase. The origin of the term theoretical plate in chromatography comes from the adaptation of an older plate theory for distillation described by Martin and Synge (Nobel Prize for Chemistry, 1952). This term which is universally used for historical reasons, has no physical significance. It may have been preferable to call it a Tswett ... [Pg.10]

Two analytical methods for priority pollutants specified by the USEPA (38) use HPLC separation and fluorescence or electrochemical detection. Method 605, 40 CFR Part 136, determines benzidine and 3,3-dichlorobenzidine by amperometric detection at +0.80 V, versus a silver/silver chloride reference electrode, at a glassy carbon electrode. Separation is achieved with a 1 1 (v/v) mixture of acetonitrile and a pH 4.7 acetate buffer (1 M) under isocratic conditions on an ethyl-bonded reversed-phase column. Lower limits of detection are reported to be 0.05 /xg/L for benzidine and 0.1 /xg/L for 3,3-dichlorobenzidine. Method 610, 40 CFR Part 136, determines 16 PAHs by either GC or HPLC. The HPLC method is required when all 16 PAHs need to be individually determined. The GC method, which uses a packed column, cannot adequately individually resolve all 16 PAHs. The method specifies gradient elution of the PAHs from a reversed-phase analytical column and fluorescence detection with an excitation wavelength of 280 nm and an emission wavelength of 389 nm for all but three PAHs naphthalene, acenaphthylene, and acenaphthene. As a result of weak fluorescence, these three PAHs are detected with greater sensitivity by UV-absorption detection at 254 nm. Thus, the method requires that fluores-... [Pg.129]

Precolumn (achiral) poly (ethylene glycol) or a suitable polar stationary phase Analytical column (chiral) ... [Pg.1031]


See other pages where Analytical phase is mentioned: [Pg.54]    [Pg.260]    [Pg.414]    [Pg.125]    [Pg.12]    [Pg.239]    [Pg.501]    [Pg.48]    [Pg.405]    [Pg.1259]    [Pg.85]    [Pg.363]    [Pg.372]    [Pg.377]    [Pg.741]    [Pg.30]    [Pg.220]    [Pg.169]    [Pg.1050]    [Pg.11]    [Pg.45]    [Pg.403]    [Pg.496]    [Pg.66]   