Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Total Ionic-Strength Adjustment Buffer

Another approach to matrix matching, which does not rely on knowing the exact composition of the sample s matrix, is to add a high concentration of inert electrolyte to all samples and standards. If the concentration of added electrolyte is sufficient, any difference between the sample s matrix and that of the standards becomes trivial, and the activity coefficient remains essentially constant. The solution of inert electrolyte added to the sample and standards is called a total ionic strength adjustment buffer (TISAB). [Pg.487]

The total ionic strength adjustment buffer serves several purposes in this procedure. Identify these purposes. [Pg.490]

Total Ionic Strength Adjustment Buffer (TISAB). Dissolve 57 mL acetic acid, 58 g sodium chloride and 4g cyclohexane diaminotetra-acetic acid (CDTA) in 500 mL of de-ionised water contained in a large beaker. Stand the beaker inside a water bath fitted with a constant-level device, and place a rubber tube connected to the cold water tap inside the bath. Allow water to flow slowly into the bath and discharge through the constant level this will ensure that in the... [Pg.571]

Total ionic strength adjustment buffers TISABs) are used to equalize Ionic activity n different solutions. [Pg.180]

It is often more convenient to relate the potentiometer reading directly to concentration by adjusting the ionic strength and hence the activity of both the standards and samples to the same value with a large excess of an electrolyte solution which is inert as far as the electrode in use is concerned. Under these conditions the electrode potential is proportional to the concentration of the test ions. The use of such solutions, which are known as TISABs (total ionic strength adjustment buffers), also allows the control of pH and their composition has to be designed for each particular assay and the proportion of buffer to sample must be constant. [Pg.180]

To leam that the change of y with ionic strength is a major cause of error in electroanalytical measurements, and so it is advisable to buffer the ionic strength (preferably at a high value), e.g. with a total ionic strength adjustment buffer (TISAB). [Pg.26]

Often, the potentiometric determination of concentration requires a preferred pH range. If pH is also important, then the ionic strength adjuster can conveniently function additionally as a pH buffer. Such tablets are called total ionic strength adjustment buffers (or TISABs). ... [Pg.57]

The fluoride content of a sample of toothpaste is unknown. Accordingly, a sample of the toothpaste was digested in acid solution, filtered to remove the white gritlike solid and then buffered with a total ionic strength adjustment buffer (TISAB) to pH 6. A fluoride electrode is immersed in the clear solution and the emf recorded when the reading was steady. [Pg.64]

The activity a and concentration c are related by a = (c/c ) x y (equation (3.12)), where y is the mean ionic activity coefficient, itself a function of the ionic strength /. Approximate values of y can be calculated for solution-phase analytes by using the Debye-Huckel relationships (equations (3.14) and (3.15)). The change of y with ionic strength can be a major cause of error in electroanalytical measurements, so it is advisable to buffer the ionic strength (preferably at a high value), e.g. with a total ionic strength adjustment buffer (TISAB). [Pg.82]

TISAB total ionic strength adjustment buffer... [Pg.377]

Frant and Ross [108] recommended sample adjustment using TISAB buffer ( Total Ionic Strength Adjustment Buffer ), obtained by dissolving 57ml glacial acetic acid, 58 g NaCl and 4g 1,2-cyclohexanediaminetetraacetic acid (CDTA), adjustment of the solution pH with sodium hydroxide to 5 to 5.5 and dilution to 1 litre, all to maintain a constant ionic strength and pH between 5 and 5.5 and to complex ions such as Al or Fe that interfere in the determination. A detailed... [Pg.152]

There are many methods that allow the determination of the concentration q of an ionic species i in a sample. In the presence of an ionic strength adjuster (ISA) or a buffering solution that can fix the pH (TISAB, Total Ionic Strength Adjustment Buffer) all of these methods are based on application of equation (18.3). [Pg.353]

A total ionic strength adjustment buffer (TISAB) is used to control the ionic strength and the pH of samples and standards in ion-selective electrode measurements. [Pg.620]

Provided. TISAB (total ionic-strength adjustment buffer) solution, which is prepared with 57 mL glacial acetic acid, 58 g sodium chloride, and 4 g CDTA (cyclohexylenedinitrUotetraacetic acid) in about 500 mL water, adjusted to pH 5.0 to 5.5 with 5 M NaOH and diluted to a total volume of 1 L. A 1 1 dilution of all samples with this solution serves the following ... [Pg.748]

TISAB 15 957 Total Ionic Strength Adjusting Buffer... [Pg.1060]


See other pages where Total Ionic-Strength Adjustment Buffer is mentioned: [Pg.487]    [Pg.490]    [Pg.532]    [Pg.780]    [Pg.565]    [Pg.866]    [Pg.72]    [Pg.507]    [Pg.98]    [Pg.534]    [Pg.539]    [Pg.54]    [Pg.507]    [Pg.510]    [Pg.202]    [Pg.396]    [Pg.261]    [Pg.150]    [Pg.688]    [Pg.235]    [Pg.38]    [Pg.957]   
See also in sourсe #XX -- [ Pg.180 ]

See also in sourсe #XX -- [ Pg.534 ]

See also in sourсe #XX -- [ Pg.620 ]

See also in sourсe #XX -- [ Pg.2 , Pg.275 ]

See also in sourсe #XX -- [ Pg.72 ]




SEARCH



Buffer strength

Ionic strength

Ionic strength adjuster

Ionic strength adjusting

Ionic strength adjustment

© 2024 chempedia.info