Order sorters

As described in Chapter 3, grating spectrometers will respond to harmonically related wavelengths that is, if a grating spectrometer is adjusted to record spectral emission at 6000 A in the first order, spectral emission at 3000 A in the second order also will be recorded at 6000 A and emission at 2000 A will be recorded as third-order emission at the same 6000 A position. Overlapping spectral orders therefore may unnecessarily complicate the observed spectrum and, in some cases, interfere with spectral lines used for analytical purposes. [Pg.118]


In addition, Echelle spectrometers are often used [50], By combination of an order-sorter and an Echelle grating either in parallel or in crossed-dispersion mode, high practical resolution (up to 300 000) can be realized with an instrument of fairly low focal length (down to 0.5 m) (Fig. 94). Therefore, the stability as well as the luminosity are high. By using an exit slit mask with a high number of preadjusted slits, highly flexible and rapid multielement determinations are possible. [Pg.206]

Figure 2.23 A filter is used as an order sorter to prevent higher order wavelengths from reaching the grating. Figure 2.23 A filter is used as an order sorter to prevent higher order wavelengths from reaching the grating.
In plasma atomic emission spectrometry the dispersing element mosdy used is a grating. Two types of grating are employed (i) conventional gratings, and (ii) echelle gratings. A fore-prism as an order-sorter is an essential feature for use with an echelle grating. The operation of conventional gratings is discussed in Section 1.6. [Pg.174]

Figure 121 illustrates a sequential echelle spectrometer. Light from the entrance slit is directed by the collimating mirror to the echelle grating, and the diffracted beam is then reflected to the prism lense (order-sorter) and focusing lense. A two-dimensional spectrum is formed in the focal plane of the system. An aperture plate, which contains preset apertures, is mounted at the focal plane. Slits and mirrors are placed at appropriate positions on a... [Pg.178]

Circular variable filters can be used in scanning monochromators they are easily calibrated, have constant resolution, are rugged, and require little maintenance. The filters also have application in radiometers, where they have replaced sets of filters of fixed wavelengths. Another application is as order sorter for spectrophotometers. [Pg.51]

Operation of a spectrometer for spectrochemical analysis utilizes, in addition to the accessory equipment already discussed, a variety of items. An optical bench is needed on which the items external to the spectrometer can be rigidly mounted. An assortment of lenses and lens holders is useful for different optical arrangements. Lenses preferably should be quartz, and a cylindrical lens is useful to focus radiation along the entrance slit of the spectrometer. Colored filters frequently are used in the external optical path to absorb radiation in certain wavelength regions and to separate overlapping spectral orders. An order sorter can be used for the same purpose. [Pg.121]

Figure 2.22 Prism used as an order sorter for a grating monochromator. Figure 2.22 Prism used as an order sorter for a grating monochromator.
When using a prism as an order sorter for a grating it is important not to decrease resolution to such an extent that the prism no longer properly sorts orders. This point can be reached in commercial instruments when fast scans are required. [Pg.438]

In searching for a polymer in this table, note that the sorter of the word processing software used in its generation sorts all characters (and not just letters) in a particular order. A parenthesis precedes a square bracket, a square bracket precedes a number, the numbers are ordered in an ascending sequence, and letters are ordered in the usual alphabetical order after numbers so that the following "alphabetical" order is used (, [, 1,2,...,8,9,10,1 l,...,a,b,...,y,z. [Pg.743]

Downstream sorting is used, and the design of the sorting system limits the number of orders that may be in process at one time. Note that the number of orders in process can often exceed the number of output chutes of a conveyor sorter (Bozer et al. 1988). [Pg.2095]

In addition to the above-mentioned experiments using PS-based nanoparticles, the hydrophobic fluorescent dye A-(2,6-diisopropylphenyl)perylene-3,4-dicarbonacidimide (PMI) could also be successfully incorporated in phosphate-functionalized poly(methylmethacrylate) (PMMA) and PS [33], polyisoprene (PI), PS-co-PI [34], PBCA [35, 36] and polylactide (PLLA), or poly(e-caprolactone) (PCL) nanoparticles [37] in order to study the cellular response to these polymeric nanoparticles. For qualitative investigations, confocal microscopy can be used the quantitative measurements can be realized by a fluorescent activated cell sorter (FACS). [Pg.7]

In order to get the causal mechanism right, we need to pick out the right causal properties at the right level of explanation. Again, let us look at Sober s familiar ball-sorter example. When we observe a number of cases of the balls sorting to then-appropriate level, we then generate a hypothesis to accoimt for what we have observed. [Pg.117]

Ron McClamrock (1995a, ch. 3) has argued that we can use the ideas of multiple realizability and context dependence to pick out preferred levels of causation and explanation. When we have token identity at different levels, we can use the ideas of multiple realizability and context dependence to hold properties at one level fixed while varying properties at other levels, in order to try to see at which level the causal mechanism occurs. In the ball-sorter case, we see that the causation occurs in virtue of size and that the macro-level of size is the right level of explanation. [Pg.148]

Order sorting It is associated with picking area, storage area, replenishment of the picking, and a sorter (Bozarth and Vilarinho 2010). [Pg.41]

The simplest method to perform the cleaning and selection operation consists of a selection platform where a number of trained sorters separate the different types of plastics on the basis of visual assessment. This is a hard and unpleasant job. Therefore, planning of works station according to ergonometric criteria is paramount in order to attain manpower s maximum efficiency, the more so if the cost of labor is considered.To the advantage of manual selection is the fact that... [Pg.101]

The great advantage of the cell-sorter separation technique is that both enriched and depleted fractions can be used for functional studies. When the separation methodology is refined further, it should be possible to use cells from unprimed animals in order to investigate the primary response. [Pg.42]


See other pages where Order sorters is mentioned: [Pg.27]    [Pg.98]    [Pg.480]    [Pg.482]    [Pg.118]    [Pg.118]    [Pg.206]    [Pg.93]    [Pg.20]    [Pg.27]    [Pg.98]    [Pg.480]    [Pg.482]    [Pg.118]    [Pg.118]    [Pg.206]    [Pg.93]    [Pg.20]    [Pg.98]    [Pg.299]    [Pg.38]    [Pg.610]    [Pg.351]    [Pg.46]    [Pg.48]    [Pg.312]    [Pg.16]    [Pg.187]    [Pg.2106]    [Pg.46]    [Pg.544]    [Pg.149]    [Pg.186]    [Pg.1983]    [Pg.610]    [Pg.15]   