Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Operation facility

AH operating facilities shear the spent fuel elements into segments several centimeters long to expose the oxide pellets to nitric acid for dissolution. This operation is often referred to as chop-leach. The design and operation of the shear is of primary importance because (/) the shear can be the production botdeneck, and (2) the shear is the point at which tritium and fission gases are released. [Pg.204]

Without exception, the highest quality EXAFS data are acquired at synchrotron radiation facilities. There are 20 operational facilities throughout the world. Each has unique instrumentation The interested user is encouraged to contact the facil-... [Pg.216]

In addition to regulatory requirements, the practical matters associated with maintaining product and personnel flow to and from operating facilities must be addressed. For example, it may be difficult to remove a rail spur for remediation of a contaminated bed, if the only means to deliver a feedstock into the facility or ship a product from the facility is this rail line. In-situ flushing or some other form of non-invasive treatment would be required to address such a problem. Similarly, jjersonnel access may have to be addressed in the planning for a corrective measures program. This is especially true in older or... [Pg.188]

Each of four teams for each mining operation consisting of a risk analyst and engineers and o 5erators performed the FRR. The risk analyst provided the FRR expertise and directed the analysis of the operation facility engineers and operators provided operational knowledge and estimated the likelihood of equipment failures and their impact on facility operations. [Pg.443]

Keep in mind that there may well be other communications vehicles in active use within your company. For example, employees at operating facilities may rely on pre-shift meetings to get information summaries some divisions and facilities may have their own newsletters in addition to a companywide publication. [Pg.29]

Each of these laboratories is a government-owned/contractor-operated facility selected from industiy, academia, and university consortia. As of 1999, the most prominent civilian contractor was Lockheed Martin, the operator of Oak Ridge and Sandia, and the major academic institution was the University of California, administrator of Los Alamos, Lawi ence Berkeley, and Lawi ence Livermore. [Pg.813]

Rocky Flats is a Government-owned and contractor-operated facility which originated in 1952. The plant s primary missions are metal fabrication, assembly, and chemical processing—with emphasis on production-related research and development. Chemical processing activities involve the recovery of plutonium from Rocky Flats Plant scrap, waste materials and residues, and effluent streams. The final product of this recovery and purification effort is high-purity plutonium metal for use in foundry operations. [Pg.365]

Compliance monitoring is used to determine a handler s level of compliance with RCRA s regulatory requirements. The primary method of collecting compliance monitoring data is through an inspection. Either U.S. EPA or an authorized state may lead inspections. Inspections must be conducted annually at all federal- or state-operated facilities and at least once every two years at each TSDF. The six types of inspections conducted under the RCRA program are2... [Pg.465]

Audit Process Audits in the chemical process industry can be focused on process safety, process safety management, environmental, and health areas. The discussion in this section will focus on the process safety and process safety management area, but it should be recognized that the process can be applied to the other areas as well. "Process safety audits are intended to provide management with increased assurance that operating facilities and process units have... [Pg.73]

The latest designs for onshore installations cater for a centralized control room, well distanced from the operating facility with sub control areas as part of a distributed control system (DCS). The sub-control areas are closer to the processes but contain fewer personnel and process control systems for the overall plant, so the overall risk level for the facility from a major incident is lowered. The outlying control buildings (sometimes referred to as PIBs or SIHs) still need to be sited against impacts from explosions and fires. [Pg.98]

To the degree that chemical hazards are identified and understood (Sections 4.2 to 4.4), and to the extent that the facility has been designed or is currently operational, facility-specific risks can be analyzed. [Pg.100]

Capabilities It is not possible to fully indicate the capabilities of MACSYMA in a few lines since the reference manual itself occupies more than 300 pages (j6) However, some of the more important capabilities include (in addition to the basic arithmetical operations) facilities to provide analytical tools for... [Pg.102]

Assessment anci Decision Making Closure Plan Development Closure Operation Facility Closeout Postclosure Activities... [Pg.72]

Their final conclusion was positive, and further visits took place in which operational facilities at country border stations of the SA Police and SA Defense Force were visited. Today some systems in the UK and France based on this original cooperation is still ongoing. [Pg.180]

Bioinjection produces no air or wastewater emissions, requires no landfilling or odor control, and can be performed in or around an operating facility. [Pg.731]

The Athabasca deposit is the site of two operational facilities Suncor, Inc. with a daily production of 8600 m3 of synthetic crude and Syncrude Canada Limited with a design production of... [Pg.70]

The Department collected data on treatment of the aqueous wastes with metals from six major sources the Department s analysis of samples collected from operating facilities, responses from the Department s Industry Survey, EPA evaluation of commercial facilities, EPA s pilot test evaluations, EPA s Development Documents for Effluent Limitations Guidelines, and the literature. Table 2 summarizes information on the treatment data sources used for the treatment levels calculations. [Pg.195]

The design flowrate of the pilot-scale test system is 10 gph or 900 L/day, which is adequate for small quantity generators, or a slip stream from a higher capacity operation could be used. Once onsite testing is completed, the system may be transported to an operating facility for demonstration testing. The test system will be constructed in four modules to simplify transportation. When the modules are prepared for shipment, only Interconnected piping will need to be separated and capped. [Pg.318]


See other pages where Operation facility is mentioned: [Pg.441]    [Pg.2058]    [Pg.2286]    [Pg.338]    [Pg.509]    [Pg.27]    [Pg.1027]    [Pg.76]    [Pg.417]    [Pg.469]    [Pg.92]    [Pg.76]    [Pg.117]    [Pg.120]    [Pg.124]    [Pg.64]    [Pg.394]    [Pg.362]    [Pg.80]    [Pg.27]    [Pg.55]    [Pg.59]    [Pg.77]    [Pg.79]    [Pg.432]    [Pg.30]    [Pg.72]    [Pg.41]    [Pg.1508]    [Pg.874]    [Pg.66]    [Pg.107]   


SEARCH



AND OPERATION OF FACILITIES

Animal testing facilities operation

Facilities laboratory operation areas

Facilities operability

Facility and Operational Changes

Operational safety of a disposal facility

Standard operating procedures testing facilities

Unit operations laboratory facilities

© 2024 chempedia.info