Operation control pressure

Fig. 2.37.2. TICI. as a function of the operation control pressure, pc. The plot is applicable only for one product in the same type of vials, the same number of vials in the same plant, the same filing height and the same Tsh (Fig. 4 from [2.31]). Fig. 2.37.2. TICI. as a function of the operation control pressure, pc. The plot is applicable only for one product in the same type of vials, the same number of vials in the same plant, the same filing height and the same Tsh (Fig. 4 from [2.31]).
Chase [2.32] presents an alternative method to monitor and control the freeze drying process by measuring the flow of nitrogen to keep the operation control pressure, pc, constant. The Mass Flow Controller (FMC) consists of a proportional valve, an integral flow meter and a capacitance manometer (CA). The CA measures the total pressure in the plant, the valve opens, if the pressure gets below the preset value and vice versa. The flow of... [Pg.170]

After evacuation and at the start of heating, the trend of Tice gets to close to the maximum tolerable Tice. A reduction in operation control pressure (pc) will immediately stop this trend (Fig. 2.37.1). (If the desired Tice is not reached pc could be raised.) As shown in Fig. [Pg.254]

After evacuation and at the start of heating, the trend of Tice approaches too close to the maximum tolerable Tice. A reduction in the operation control pressure (pc) will immediately stop this trend (Figure 2.88) (if the desired Tice is not reached p could be raised.) The slope of the function Tice =j[pt) can become unfavorably steep. In this case, the shelf temperature should also be lowered or raised, but the effect of this change will take time before an equilibrium state is reached again (e.g. 0.5-1 h) depending on the heat transfer conditions and the heat capacity of the shelves and the heat transfer medium. [Pg.368]

A schematic of a continuous bulk SAN polymerization process is shown in Figure 4 (90). The monomers are continuously fed into a screw reactor where copolymerization is carried out at 150°C to 73% conversion in 55 min. Heat of polymerization is removed through cooling of both the screw and the barrel walls. The polymeric melt is removed and fed to the devolatilizer to remove unreacted monomers under reduced pressure (4 kPa or 30 mm Hg) and high temperature (220°C). The final product is claimed to contain less than 0.7% volatiles. Two devolatilizers in series are found to yield a better quaUty product as well as better operational control (91,92). [Pg.195]

In most utibty boilers, steam pressure regulation is achieved by the throttling of turbine control values where steam generated by the boiler is admitted into the steam turbine. Some modem steam generators have been designed to operate at pressures above the critical point where the phase change between Hquid and vapor does not occur. [Pg.5]

All results besides (1) and (2) are, however, usually of more distant concern. Primarily emphasis on understanding and operating controls should be placed on those two items. It will sometimes be found that no pressure or temperature controls are needed if good, quick sensors are available to show what overall split is being made and what separation is occurring. [Pg.66]

These ratios are useful in dealing with small towers, and serve as guides for the borderline cases of others. There are no guides to the smallest sized packing to place in a tower. However, /4-in. is about the smallest ceramic used with %-in. and 1-in. being the most popular. Operating and pressure drop factors will usually control this selection. [Pg.280]

Figure 12-138A, B, C, D. Centrifugal fan system control methods. Note the effect of air distribution zone control (A for VAV) terminal on sudden jump in system resistance to fan operating static pressure curve. (Used by permission Haines, R. W. Heating/Piping/Air Conditioning, p. 107, Aug. 1983. Penton Media, Inc. All rights reserved.)... Figure 12-138A, B, C, D. Centrifugal fan system control methods. Note the effect of air distribution zone control (A for VAV) terminal on sudden jump in system resistance to fan operating static pressure curve. (Used by permission Haines, R. W. Heating/Piping/Air Conditioning, p. 107, Aug. 1983. Penton Media, Inc. All rights reserved.)...
There are several primary operating control inputs for rotary positive-displacement compressors. These control inputs are discharge pressure, pressure fluctuations, and unloading frequency. [Pg.561]

The safe and efficient operation of fluid power systems, system components and related equipment requires a means to control pressure within the system. There are many types of automatic pressure control valves. Some of them merely provide an escape for excess pressures some only reduce the pressure and some keep the pressure within a pre-set range. [Pg.612]

Over the years the performance standards of hydraulic equipment have risen. Whereas a pressure of about 1000 psi used to be adequate for industrial hydraulic systems, nowadays systems operating with pressures of 2000-3500psi are common. Pressures above 5000psi are to be found in applications such as large presses for which suitable high-pressure pumps have been developed. Additionally, systems have to provide increased power densities, more accurate response, better reliability and increased safety. Their use in numerically controlled machine tools and other advanced control systems creates the need for enhanced filtration. Full flow filters as fine as 1-10 micron retention capabilities are now to be found in many hydraulic systems. [Pg.862]

Face lubricated-type seals must be connected from the source of lubrication to the tap openings in the seal gland before startup. This is another predetermined environmental control feature that is mandatory for proper seal function. Where double seals are to be operated, it is necessary that the lubrication feed lines be connected to the proper ports for both circulatory or dead-end systems before equipment startup. This is very important because all types of double seals depend on the controlled pressure and flow of the sealing fluid to function properly. Even before the shaft is rotated, the sealing liquid pressure must exceed the product pressure opposing the seal. Be sure a vapor trap does not prevent the lubricant from reaching the seal face promptly. [Pg.953]

Water-steam checks include monitoring boiler NOWL and operating steam pressure, and the periodic testing of low-water cutoff controls, pressure gauges, and the FW regulator valve. [Pg.120]

The sample is assembled into the permeation cell after first having had its thickness accurately measured, with the sample supported by a stainless steel porous sinter (not visible in the photographs). The test cell is heated to test temperature by suitably controlled band-heaters, test temperature being measured by a thermocouple located close to the sample. Test gases are boosted to test pressure using a gas intensifier operated by pressurized air. [Pg.643]


See other pages where Operation control pressure is mentioned: [Pg.225]    [Pg.225]    [Pg.269]    [Pg.399]    [Pg.413]    [Pg.34]    [Pg.151]    [Pg.407]    [Pg.795]    [Pg.2499]    [Pg.258]    [Pg.12]    [Pg.326]    [Pg.416]    [Pg.486]    [Pg.452]    [Pg.132]    [Pg.38]    [Pg.161]    [Pg.303]    [Pg.554]    [Pg.203]    [Pg.323]    [Pg.561]    [Pg.1024]    [Pg.9]    [Pg.474]    [Pg.661]    [Pg.115]    [Pg.315]    [Pg.16]    [Pg.322]   