Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Level of detection

The evidence outlined strongly suggests that nitration via nitrosation accompanies the general mechanism of nitration in these media in the reactions of very reactive compounds.i Proof that phenol, even in solutions prepared from pure nitric acid, underwent nitration by a special mechanism came from examining rates of reaction of phenol and mesi-tylene under zeroth-order conditions. The variation in the initial rates with the concentration of aromatic (fig. 5.2) shows that mesitylene (o-2-0 4 mol 1 ) reacts at the zeroth-order rate, whereas phenol is nitrated considerably faster by a process which is first order in the concentration of aromatic. It is noteworthy that in these solutions the concentration of nitrous acid was below the level of detection (< c. 5 X mol... [Pg.91]

Recommended Equipment. A list of analy2ers (stand-alone or in a mobile cart) and level of detection for specific gas and particle analysis... [Pg.90]

The comparison of the results of very different methods has to be judged very precisely, as, e.g., the given thickness of a layer is a function of the limit of detection (EOD) of a method. Additionally, the detected areas vary from about 0.01 up to about 400 mm-. Therefore, the methods with a low level of detection and with a high sensitivity (high slope of the calibration function) give a higher value for the layer thickness. Furthermore, the layers are broadened with time by diffusion. [Pg.411]

Hi) Specialized Analytical Methods. Analytical methods for metallic impurities are well documented and are not covered here. A major advance in the continuous monitoring of impurities in liquid sodium down to the lowest levels of detection has been the development of analysis using electrochemical cells. Oxygen analysis in sodium may be carried out using a cell of the type... [Pg.337]

The shape of the matrix peaks depends on the nature of the sample and also on the composition of the HPLC solvent system. For an HPLC column, a low level of detection requires that interfering peaks in the samples be minimal. [Pg.336]

A portion of the Wilk/STA catalyst was re-used for the hydrogenation of successive 10,000 TON batches of 1-hexene with the TOP remaining constant for each run. A separate portion of this catalyst was also used for the 100,000 TON hydrogenation of 1-hexene with a TOP of 4800 hr. In each of these reactions the amount of Rh in the reaction mixture was below the level of detection, less than 1 ppm. [Pg.182]

Percent solid settled In tests where adsorption and flocculation were determined simultaneously, the 200 ml sample was allowed to settle for 30 seconds and then 100 ml of the supernatant was removed using a suction device and after centrifugation analyzed for residual polymer concentration. The minimum level of detection was at 0.5 to 1 ppm and the reproducibility of the adsorption measurements was 2-3%. The settled 100 ml portion was analyzed for solid content. Flocculation due to polymer addition is measured by noting % solid settled as a function of polymer concentration. [Pg.395]

Femtomol levels of detection limits were also achieved in the determination of stimulant amines with the benzofurazan derivative 4-(Af,Af-dimethylaminosul-phonyl)-7-fluoro-2,l,3-benzoxadizole (DBD-F) [73], DBD-F was successfully applied to the PO-CL detection of amino acids and epinephrine [74] and a P-blocker, metoprolol [75], 4-(Af,Af-Dimethylaminosulphonyl)-7-hydrazino-2,l,3-benzoxadizole (DBD-H) has also been used for PO-CL determination of a neuronal cell protective compound, propentofylline. The method was applied for the first time to determine propentofylline concentration in the dialysate obtained from the rat hippocampus [85],... [Pg.414]

A Cases reported above level of detection B Cases tested but below level of detection C Cases not tested D Cases unknown... [Pg.24]

The use of potent combination antiretroviral therapy to suppress HIV replication to below the levels of detection of sensitive plasma HIV RNA assays limits the potential for selection of antiretroviral-resistant HIV variants, the major factor limiting the ability of antiretroviral drugs to inhibit virus replication and delay disease progression. [Pg.451]

As the OPCW biomedical sampling requirement is of the lowest level of detection possible, the samples would be presented to the lab with as much relevant information as possible, to enable the most appropriate... [Pg.126]

Multi-Element Analytical Scheme The 76 elements analyzed include 39 elements originally analyzed in the RGNR Projects, and 37 new elements. The analytical scheme is based largely on ICPMS, ICPAES and XRF, supplemented with other techniques (Table 1). The lower levels of detection of all elements are less than their crustal abundances (Table 2). [Pg.397]


See other pages where Level of detection is mentioned: [Pg.90]    [Pg.661]    [Pg.449]    [Pg.338]    [Pg.206]    [Pg.215]    [Pg.232]    [Pg.93]    [Pg.356]    [Pg.385]    [Pg.211]    [Pg.5]    [Pg.18]    [Pg.975]    [Pg.44]    [Pg.87]    [Pg.526]    [Pg.196]    [Pg.60]    [Pg.62]    [Pg.67]    [Pg.61]    [Pg.88]    [Pg.214]    [Pg.252]    [Pg.257]    [Pg.260]    [Pg.261]    [Pg.327]    [Pg.398]    [Pg.414]    [Pg.228]    [Pg.291]    [Pg.432]    [Pg.447]    [Pg.60]    [Pg.303]    [Pg.253]   
See also in sourсe #XX -- [ Pg.442 ]




SEARCH



Detection levels

© 2024 chempedia.info