Kinetic sampling

Obtaining Kinetic Samples for Reactive Extrusion. To develop and test kinetic models, homogeneous samples with a well defined temperature-time history are required. Temperature history does not necessarily need to be isothermal. In fact, well defined nonisothermal histories can provide very good test data for models. However, isothermal data is very desirable at the initial stages of model building to simplify both model selection and parameter estimation problems. [Pg.508]

Use of a static mixer to obtain kinetic samples does have some difficult aspects associated with it ... [Pg.508]

As mentioned above, two experimental methods were examined as a source of kinetic samples Method A Agitated Glass Ampoule and Method B Static Mixer. These are described in turn in the following paragraphs. Analysis of samples was done using high temperature size exclusion chromatography (SEC) under conditions previously described (9.101. [Pg.510]

Results of Method A The agitated ampoule method proved to have too many constraints to be useful as a method for obtaining kinetic samples for this reactive extrusion. The constraints were as follows o High initiator concentrations (>0.04 wt %) and high temperatures (e.g. [Pg.515]

Huckins, J.N. Petty, J.D. Orazio, C.E. Lebo, J.A. Clark, R.C. Gibson, V.L. Gala, W.R. Echols, K.R. 1999, Determination of uptake kinetics (sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water. Environ. Sci. Technol. 33 3918-3923. [Pg.42]

Because Cs increases linearly with time, this phase of an exposure is called kinetic sampling , or the linear uptake mode , and sampling is time-integrative. The amount (N) absorbed by SPMDs during kinetic sampling equals... [Pg.50]

Experiments on recovery of dynamic functions after the application of large strain amplitude perturbation were performed to understand the modulus recovery kinetics. To determine the recovery kinetics, samples underwent the following test sequences (a) frequency sweep, (b) strain sweep, (c) relaxation time of 2 min, (d) frequency sweep, (e) strain sweep, (f) relaxation time of 2 min, (g) frequency sweep, and (h) strain sweep [50]. Figure 7 shows the comparative subsequent strain sweep results performed immediately after a relaxation time of... [Pg.231]

Among the kinetic sampling devices, ceramic dosimeters have been used successfully for the long-term surveillance of VOCs.92 They use a ceramic tube as the diffusion-limiting barrier that encloses a receiving phase consisting of solid sorbent beads. Over a three-month deployment in a contaminated aquifer, the ceramic dosimeter provided TWA concentrations of benzene, toluene, ethylbenzenes, xylenes, and naphthalenes. The levels obtained matched closely those found in spot water samples that were taken frequently over the trial period.54... [Pg.54]

Satisfactory withdrawal requires iso-kinetic sampling or at least a good approximation to it. Draught-tube, bafiled tanks have a relatively well-defined vertical flow, particularly around the mid-depth of the draught-tube. A withdrawal pipe then can be aligned with the flow but the velocity must be greater than Sut for satisfactory transporT and at the same time it must satisfy the stoichiometry. These two requirements cause problems in small scale systems but intermittent withdrawal at the point in the annulus of maximum velocity may provide an answer. [Pg.384]

Kinetic sample injection is a method which employs electroosmotic flow to load and separate the samples for chemical and biomedical analysis in many bio- or chemical Lab-on-a-Chip. It is one of the injection techniques used for the microfluidic injector within microfluidic devices. The typical volume delivered by kinetic injection is about htmdreds of picoliters. [Pg.837]

Microfluidics is promising for developing tools with integrated chenucal processing of proteomics analytes, by virtue of fast reaction kinetics. Sample purification and concentration can be carried out on the microscale by methods such as solid-phase extraction on hydrophobic... [Pg.2889]

Iso-kinetic sampling generally is used to measure solids mass flux profiles. The sampling probe is a thin tube inserted through the vessel wall. The tip of the tube is bent at a 90° angle so that it is parallel to the flow stream. The tube velocity is adjusted to match the surrounding velocity so as not to disturb the main flow. Solids enter the tube then are separated from the gas with a cyclone. [Pg.265]

Figure 2.15 Illustration of the use of autocorrelation to probe conformational dynamics. Autocorrelation functions are measured for the kinetic sample (top, solid line) and the control sample (top, broken line), which has no dynamic conformational component. The ratio of these autocorrelation functions leaves only the conformational dynamics component (bottom, grey broken line) which can be fit with, in this case, a stretched exponential (bottom, solid black line) to extract the observed rate constant for the transition. In this case the dynamic sample was an RNA hairpin labelled with fluorescein. When the hairpin was formed the dye was brought near a quencher, thus modulating the fluorescence emission and providing fluctuations to be probed via autocorrelation. The control sample lacked the quencher. Figure 2.15 Illustration of the use of autocorrelation to probe conformational dynamics. Autocorrelation functions are measured for the kinetic sample (top, solid line) and the control sample (top, broken line), which has no dynamic conformational component. The ratio of these autocorrelation functions leaves only the conformational dynamics component (bottom, grey broken line) which can be fit with, in this case, a stretched exponential (bottom, solid black line) to extract the observed rate constant for the transition. In this case the dynamic sample was an RNA hairpin labelled with fluorescein. When the hairpin was formed the dye was brought near a quencher, thus modulating the fluorescence emission and providing fluctuations to be probed via autocorrelation. The control sample lacked the quencher.
Pivotal safety studies in a single relevant species are usually appropriate for MAbs, as are single-dose pharmacokinetic studies, a multiple-dose toxicity assessment with toxico-kinetic sampling, and immunogenicity studies. [Pg.151]


See other pages where Kinetic sampling is mentioned: [Pg.507]    [Pg.515]    [Pg.373]    [Pg.50]    [Pg.487]    [Pg.215]    [Pg.41]    [Pg.43]    [Pg.44]    [Pg.105]    [Pg.487]    [Pg.57]    [Pg.248]    [Pg.249]    [Pg.40]    [Pg.305]    [Pg.95]    [Pg.38]    [Pg.262]    [Pg.1753]    [Pg.697]    [Pg.358]   
See also in sourсe #XX -- [ Pg.44 , Pg.45 , Pg.47 ]




SEARCH



Application of Sparse Sampling and Population Kinetic Methods

Kinetic and Equilibrium Sampling

Kinetic studies, experimental methods sampling

Sampling Kinetic Protein Folding Pathways using All-Atom Models Bolhuis

Sampling and analysis for kinetics

With halting of the flow between samples kinetic titrations

© 2024 chempedia.info