Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ionic Ionisation

To date there is no evidence that sodium forms any chloride other than NaCl indeed the electronic theory of valency predicts that Na" and CU, with their noble gas configurations, are likely to be the most stable ionic species. However, since some noble gas atoms can lose electrons to form cations (p. 354) we cannot rely fully on this theory. We therefore need to examine the evidence provided by energetic data. Let us consider the formation of a number of possible ionic compounds and first, the formation of sodium dichloride , NaCl2. The energy diagram for the formation of this hypothetical compound follows the pattern of that for NaCl but an additional endothermic step is added for the second ionisation energy of sodium. The lattice energy is calculated on the assumption that the compound is ionic and that Na is comparable in size with Mg ". The data are summarised below (standard enthalpies in kJ) ... [Pg.75]

Element Ionisation energy (kj mof ) Metallic radius (nm) Ionic radius (nm) Heal oj laporibation at 298 K (kJ mol ) Hydration energy oj gaseous ion (kJ moI ) (V)... [Pg.120]

In an excess of nitric acid, nitrous acid exists essentially as dinitrogen tetroxide which, in anhydrous nitric acid, is almost completely ionised. This is shown by measurements of electrical conductivity, and Raman and infra-red spectroscopy identify the ionic species... [Pg.55]

Mode of Motion. Nicotine, anabasine, and imidocloprid affect the ganglia of the insect central nervous system, faciUtating transsynaptic conduction at low concentrations and blocking conduction at higher levels. The extent of ionisation of the nicotinoids plays an important role in both their penetration through the ionic barrier of the nerve sheath to the site of action and in their interaction with the site of action, which is befleved to be the acetylcholine receptor protein. There is a marked similarity in dimensions between acetylcholine and the nicotinium ion. [Pg.269]

When sulfuric acid is present in the mixed acids, the following ionisation reactions occur. These ionic reactions are rapid, and equiHbrium concentrations of NO2 are likely to be present at all times in the acid phase. NO2 concentrations depend mainly on the composition of the mixed acids but decrease to some extent as the temperature increases (3). [Pg.32]

The alkah flame-ionisation detector (AFID), sometimes called a thermionic (TID) or nitrogen—phosphoms detector (NPD), has as its basis the fact that a phosphoms- or nitrogen-containing organic material, when placed ia contact with an alkaU salt above a flame, forms ions ia excess of thermal ionic formation, which can then be detected as a current. Such a detector at the end of a column then reports on the elution of these compounds. The mechanism of the process is not clearly understood, but the enhanced current makes this type of detector popular for trace analysis of materials such as phosphoms-containing pesticides. [Pg.108]

The higher ionisation energy and smaller ionic radius of copper contribute to its forming oxides much less polar, less stable, and less basic than those of the alkah metals (13). Because of the relative instabiUty of its oxides, copper joins silver in occurring in nature in the metallic state. [Pg.195]

Langmuir isotherms are typically found with ionic synthetic fibers and ionic dyes, eg, dyeing polyacrylonitrile with modified basic dyes, and on hydrophilic fibers in situations when the number of sites becomes very low. This may arise when the internal pH is such that only a small number of sites ionise. [Pg.352]

Such vessels can also be baked at a temperature of several hundred degrees, to drive off any gas adsorbed on metal surfaces. The pumping function of an ion gauge was developed into efficient ionic pumps and turbomolecular pumps , supplemented by low-temperature traps and cryopumps. Finally, sputter-ion pumps, which rely on sorption processes initiated by ionised gas, were introduced. A vacuum of 10 "-10 Torr, true UHV, became routinely accessible in the late 1950s, and surface science could be launched. [Pg.406]

The typical strong acid of the water system is the hydrated proton H30+, and the role of the conjugate base is minor if it is a sufficiently weak base, e.g. Cl-, Br-, and C104. The conjugate bases have strengths that vary inversely as the strengths of the respective acids. It can easily be shown that the basic ionisation constant of the conjugate base KR canj is equal to Kw/KA conj, where Kw is the ionic product of water. [Pg.22]

Since water is only slightly ionised, the ionic concentrations will be small, and their activity coefficients may be regarded as unity the activity of the un-ionised molecules may also be taken as unity. The expression thus becomes ... [Pg.37]

The hydrolysis constant is thus related to the ionic product of water and the ionisation constant of the acid. Since Ka varies slightly and Kw varies considerably with temperature, Kh and consequently the degree of hydrolysis will be largely influenced by changes of temperature. [Pg.43]

Purity of water. The purity of distilled or de-ionised water is commonly checked by conductimetric measurements. The conductivity of pure water is about 5 x 10-8Q-1 cm-1, and the smallest trace of ionic impurity leads to a large increase in conductivity. Conductimetric monitoring is employed in laboratories to check the operation of ion exchange units producing de-ionised water, and finds similar industrial application where processes requiring the use of very pure water (e.g. manufacture of semiconductors) are carried on. [Pg.521]

Total Ionic Strength Adjustment Buffer (TISAB). Dissolve 57 mL acetic acid, 58 g sodium chloride and 4g cyclohexane diaminotetra-acetic acid (CDTA) in 500 mL of de-ionised water contained in a large beaker. Stand the beaker inside a water bath fitted with a constant-level device, and place a rubber tube connected to the cold water tap inside the bath. Allow water to flow slowly into the bath and discharge through the constant level this will ensure that in the... [Pg.571]

Ionic strength adjuster buffer 565, 570 Ionisation constants of indicators, 262, (T) 265 of acids and bases, (T) 832, 833, 834 see also Dissociation constants Ionisation suppressant 793 Iron(II), D. of by cerium(IV) ion, (cm) 546 by cerium(IV) sulphate, (ti) 382 by potassium dichromate, (ti) 376 by potassium permanganate, (ti) 368 see also under Iron... [Pg.866]

The mechanism of decarboxylation of acids containing an amino substituent is further complicated by the possibility of protonation of the substituent and the fact that the species NH2ArCOOH is kinetically equivalent to the zwitterion NHj ArCOO. Both of these species, as well as the anion NH2 ArCOO" and even NH3 ArCOOH must be considered. Willi and Stocker644 investigated by the spectroscopic method the kinetics of the acid-catalysed decarboxylation of 4-aminosalicyclic acid in dilute hydrochloric acid, (ionic strength 0.1, addition of potassium chloride) and also in acetate buffers at 20 °C. The ionisation constants K0 = [HA][H+][H2A+] 1 (for protonation of nitrogen) and Kx = [A"][H+] [HA]-1, were determined at /i = 0.1 and 20 °C. The kinetics followed equation (262)... [Pg.312]

Table 6.10 reports the main areas of application of the various ionisation methods and the principal ions detected. A breakdown of MS techniques applied to various types of analytes is as follows thermally stable, low-MW Cl, El thermally instable, low-MW APCI (FLA, LC-MS), ESI and high-MW DCI, FD, FAB, LD, ESI (FLA, LC-MS, CZE-MS). Soft ionisation techniques such as FL, FAB and LD are useful for the detection of non-volatile, sometimes oligomeric, polymer additives. Recent developments in ionisation techniques have allowed the analysis of polar, ionic, and high-MW compounds, previously not amenable to mass-spectrometric analysis. Figure 6.4 shows the applicability of various atmospheric pressure ionisation techniques in terms of molar mass and polarity. [Pg.359]

Quantitative analysis using FAB is not straightforward, as with all ionisation techniques that use a direct insertion probe. While the goal of the exercise is to determine the bulk concentration of the analyte in the FAB matrix, FAB is instead measuring the concentration of the analyte in the surface of the matrix. The analyte surface concentration is not only a function of bulk analyte concentration, but is also affected by such factors as temperature, pressure, ionic strength, pH, FAB matrix, and sample matrix. With FAB and FTB/LSIMS the sample signal often dies away when the matrix, rather than the sample, is consumed therefore, one cannot be sure that the ion signal obtained represents the entire sample. External standard FAB quantitation methods are of questionable accuracy, and even simple internal standard methods can be trusted only where the analyte is found in a well-controlled sample matrix or is separated from its sample matrix prior to FAB analysis. Therefore, labelled internal standards and isotope dilution methods have become the norm for FAB quantitation. [Pg.369]

The ideal mass-spectrometric interface should allow for a range of ionisation methods (Tables 7.23 and 7.24). The ionisation of organic molecules for use with chromatographic outlets include El, Cl, APCI for samples that can be vaporised prior to ionisation alternative ionisation techniques using TSP, ESP or FAB are needed for labile, high-MW or ionic samples. [Pg.455]

Electrospray has been successful for numerous azo dyes that are not ionic salts. Several anthraquinone dyes have been analysed by LC-ESI-MS [552]. Electrospray achieves the best sensitivity for compounds that are precharged in solution (e.g. ionic species or compounds that can be (de)protonated by pH adjustment). Consequently, LC-ESI-MS has focused on ionic dyes such as sulfonated azo dyes which have eluded analysis by particle-beam or thermospray LC-MS [594,617,618]. Techniques like LC-PB-MS and GC-MS, based on gas-phase ionisation, are not suitable for nonvolatile components such as sulfonated azo dyes. LC-TSP-MS on... [Pg.514]

LC-tandem MS was recently used for polymer/additive characterisation. In cases of soft ionisation processes (e.g. ESI, APCI, etc.), MS/MS is often necessary to confirm the ionic species. QITMS has the potential to improve the detection limits for organotin analysis compared to QMS. HPLC-UV and LC-API-MS/MS have been employed for the characterisation of the products of photodegradation of benzotriazole-based UV absorbers (Tinuvin P/328/900) under mild conditions [642]. Among the photoproducts identified... [Pg.519]

Although electrospray ionisation has advantages for studies of ionic and very polar molecules, APCI is the preferred ionisation method for many other compounds - in that it provides better sensitivity and has advantages for quantitative studies. CE-APCI-MS studies were conducted on both QQQ and QITMS instruments [887]. [Pg.544]


See other pages where Ionic Ionisation is mentioned: [Pg.218]    [Pg.218]    [Pg.50]    [Pg.76]    [Pg.121]    [Pg.134]    [Pg.139]    [Pg.354]    [Pg.21]    [Pg.54]    [Pg.278]    [Pg.20]    [Pg.37]    [Pg.207]    [Pg.321]    [Pg.173]    [Pg.696]    [Pg.6]    [Pg.119]    [Pg.40]    [Pg.376]    [Pg.351]    [Pg.355]    [Pg.358]    [Pg.360]    [Pg.370]    [Pg.381]    [Pg.382]    [Pg.484]   
See also in sourсe #XX -- [ Pg.46 , Pg.116 ]




SEARCH



Ionisation

Ionised

© 2024 chempedia.info